In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E, and the ECR figure in September was 3.65E, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E, six times higher than R7 measured in October, and 1.87E in July, four times higher than R9.

Abstract

In this study, in order to grasp the current situation of indoor environmental pollution and indoor ventilation in one-room around the university in the post-corona era, we analyzed the experimental data and conducted a questionnaire survey on university students. By analyzing the content, the effects of formaldehyde, dust and other pollution on the human body, which are usually not easily detectable, are digitized and more easily taken into account. Among the experimental results, the concentration of VOC and HCHO, gas pollutants among indoor pollutants, exceeded the recommended criteria of the Ministry of Environment in most studio apartments. Overall, the average CO concentration was lower than the Ministry of Environment's maintenance standard (1000ppm), but it was relatively high in summer and winter, and it is believed to be caused by cooling and heating in an enclosed space. The levels of PM2.5 and PM10, particulate pollutants, increased in November and December, and it is believed that ventilation defects due to degradation in external temperature. There was no clear difference between the two types, and there was a very high correlation between PM2.5 and PM10, HCHO and VOC. It was found that temperature was closely correlated with all sources except CO, and humidity was closely correlated with all sources except PM2.5 and PM10. Health risk assessment was conducted for formaldehyde. The average ECR of studio R2 in May was 3.91E, and the ECR figure in September was 3.65E, which was very high compared to other residential spaces. The R2 level was calculated as 4 people per 10,000 people in the lifetime risk of cancer of residents, exceeding the allowable risk. R8 also showed higher ECR results than other spaces after R2, especially in October, 2.01E, six times higher than R7 measured in October, and 1.87E in July, four times higher than R9.

참고문헌 (16)

  1. 김현주, "The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment", 분석과학, 33(1), pp.49~57 (2020), 한국분석과학회
  2. 남기철, "주택 실내 공기환경 실태조사에 관한 기초연구", 석사, pp.2017
  3. 박수정, "천식 환자 가정의 시간활동에 따른 초미세먼지(PM2.5) 농도의연관성 분석", 석사, pp.2019
  4. 염지선, "대한보건협회 보건종합학술대회", 대한보건협회 보건종합학술대회, 2011 (2011)
  5. 이시내, "거주후 평가를 통한 공동주택의 실내환경 성능평가요소 분석에 관한 연구", 한국태양에너지학회 논문집, 31(2), pp.128~134 (2011), 한국태양에너지학회
  6. 이철구, "건축환경의 이해" (2017), 세진사
  7. 장하나, "오피스텔의 실내공기환경 개선에 관한 연구-거주자의 의견과 요구사항을 중심으로-", 한국주거학회논문집, 18(1), pp.123~129 (2007), 한국주거학회
  8. 정경윤, "오피스 건물의 실내 공기환경 실태조사에 관한 연구", 석사, 건축공학과 건축설비및에너지전공, pp.2013
  9. 최윤정, "거주중인 원룸형 다가구주택의 건축경년에따른 실내공기질 비교", 한국생활과학회 학술대회논문집, 2013(5) (2013)
  10. 포위, "전북대학교 주변 원룸의 환기평가와 CFD를 이용한 시뮬레이션해석", 석사, pp.2021
  11. 한정우, "신축 원룸형 다가구 주택의 실내공기질에 관한 연구", 석사, pp.2017
  12. 배현주, "서울시 미세먼지(PM10)와 초미세먼지(PM2.5)의 단기노출로 인한 사망영향", 한국환경보건학회지, 40(5), pp.346~354 (2014), 한국환경보건학회[DOI]
  13. 조경화, "민감시설의 건물 특성에 따른 실내공기질 분석", 의료·복지 건축, 23(2), pp.19~26 (2017), 한국의료복지건축학회[DOI]
  14. 장재연, "General Factors of the Korean Exposure Factors Handbook", 예방의학회지, 47(1), pp.7~17 (2014), 대한예방의학회
  15. Korea Environment Corporation, "Multi-use indoor air quality consulting business: Elderly care facility, day care center, postnatal care center", ~ (2011)
  16. 원수란, "국내 다중이용시설에서의 PM2.5와 PM10 농도분포 특성", 한국실내환경학회지, 9(3), pp.229~238 (2012), 한국실내환경학회