The purpose of this study is to evaluate the accuracy of digital surgical guide according to implant position. Dentiform with D2 bone density, which has a #15, 16, 17, 24, 25, 26, 34, 35, 36, 45, 46, 47 edentulous space, is fabricated. Model scanning and cone beam computed tomography (CBCT) data was taken and overlapped using In2Guide software, and the implants were planned. The digital surgical guide was fabricated using 3D printing and the implants were installed using the surgical stent. CBCT were retaken after the implants were installed, and the “before” surgery and “after” surgery CBCTs were overlapped. Then, the degree differences and length differences at implant shoulder and tip area were statistically analysed. The mesial implant of the tooth-supported type showed 1.06±0.53°, 0.29±0.19 mm, 0.39±0.24 mm, the middle implant showed 1.36±0.67°, 0.40±0.15 mm, 0.42±0.23 mm and the distal implant showed 1.39±0.69°, 0.59±0.29 mm, 0.67±0.41 mm respectively. The mesial implant of the tissue-supported type showed 1.76±0.83°, 0.57±0.29 mm, 0.88±0.31 mm, the middle implant showed 2.15±0.65°, 0.69±0.25 mm, 1.08±0.28 mm. and the distal implant showed 2.83±1.17°, 1.09±0.50 mm, 1.34±0.45 mm. The greater the proximity of the implant to the mesial side, the smaller the error.
Abstract
The purpose of this study is to evaluate the accuracy of digital surgical guide according to implant position. Dentiform with D2 bone density, which has a #15, 16, 17, 24, 25, 26, 34, 35, 36, 45, 46, 47 edentulous space, is fabricated. Model scanning and cone beam computed tomography (CBCT) data was taken and overlapped using In2Guide software, and the implants were planned. The digital surgical guide was fabricated using 3D printing and the implants were installed using the surgical stent. CBCT were retaken after the implants were installed, and the “before” surgery and “after” surgery CBCTs were overlapped. Then, the degree differences and length differences at implant shoulder and tip area were statistically analysed. The mesial implant of the tooth-supported type showed 1.06±0.53°, 0.29±0.19 mm, 0.39±0.24 mm, the middle implant showed 1.36±0.67°, 0.40±0.15 mm, 0.42±0.23 mm and the distal implant showed 1.39±0.69°, 0.59±0.29 mm, 0.67±0.41 mm respectively. The mesial implant of the tissue-supported type showed 1.76±0.83°, 0.57±0.29 mm, 0.88±0.31 mm, the middle implant showed 2.15±0.65°, 0.69±0.25 mm, 1.08±0.28 mm. and the distal implant showed 2.83±1.17°, 1.09±0.50 mm, 1.34±0.45 mm. The greater the proximity of the implant to the mesial side, the smaller the error.
참고문헌 (9)
- Derhalli M., "The digitalizing of implant dentistry: a clinical evaluation of 15 patients", Compend Contin Educ Dent, 34, pp.192~196 (2013)
- Ganz SD, "Use of stereolithographic models as diagnostic and restorative aids for predictable immediate loading of implants", Pract Proced Aesthet Dent, 15, pp.763~771 (2003)
- Hajeer MY, "Applications of 3D imaging in orthodontics: part II", J Orthod, 31, pp.154~162 (2004)[DOI]
- Volkan Arısan, "Accuracy of Two Stereolithographic Guide Systems for Computer-Aided Implant Placement: A Computed Tomography-Based Clinical Comparative Study", Journal of Periodontology, 81(1), pp.43~51 (2010), Wiley-Blackwell[DOI]
- Ahmet Ersan Ersoy, "Reliability of Implant Placement With Stereolithographic Surgical Guides Generated From Computed Tomography: Clinical Data From 94 Implants", Journal of Periodontology, 79(8), pp.1339~1345 (2008), Wiley-Blackwell[DOI]
- Oguz Ozan, "Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement", Journal of Oral and Maxillofacial Surgery, 67(2), pp.394~401 (2009), Elsevier BV[DOI]
- Daniel van Steenberghe, "Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers", Clinical Oral Implants Research, 14(1), pp.131~136 (2003), Wiley-Blackwell[DOI]
- Vinicius Nery Viegas, "Transference of virtual planning and planning over biomedical prototypes for dental implant placement using guided surgery", Clinical Oral Implants Research, 21(3), pp.290~295 (2010), Wiley-Blackwell[DOI]
- 김원, "Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사", 구강회복응용과학지, 27(2), pp.175~184 (2011), 대한턱관절교합학회