코딩된 치유 지대주를 이용한 디지털 방식의 임플란트 인상채득 방법에 대한 고찰
A Review of the Digital Impression Taking Technique of Implants by Using a Coded Healing Abutment
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Conventional implant-level impression techniques required removal of healing abutments at least twice until the placement of definitive restorations. The use of coded healing abutments may simplify this procedure since they provide information necessary to design implant abutments such as implant hex position and platform diameter. This could minimize peri- implant tissue irritation and reduce the laboratory time and costs when used in combination with an intraoral scanner. The aims of this article were to describe the structure, clinical availability, and limitations of the coded healing abutments and review the studies related to their use.
Abstract
Conventional implant-level impression techniques required removal of healing abutments at least twice until the placement of definitive restorations. The use of coded healing abutments may simplify this procedure since they provide information necessary to design implant abutments such as implant hex position and platform diameter. This could minimize peri- implant tissue irritation and reduce the laboratory time and costs when used in combination with an intraoral scanner. The aims of this article were to describe the structure, clinical availability, and limitations of the coded healing abutments and review the studies related to their use.
참고문헌 (17)
- Ting-Shu S, "Intraoral digital impression technique: a review", J Prosthodont, 24, pp.313~321 (2015)
- Christensen GJ., "Will digital impressions eliminate the current problems with conventional impressions?", J Am Dent Assoc, 139, pp.761~763 (2008)
- Vandeweghe S, "Accuracy of digital impressions of multiple dental implants: an in vitro study", Clin Oral Implants Res, 28, pp.648~653 (2017)
- Abrahamsson I, "The mucosal barrier following abutment dis", reconnection. An experimental study in dogs, 1997, pp.24, 568~572
- Priest G., "Virtual-designed and computer-milled implant abutments", J Oral Maxillofac Surg, 63, pp.22~32 (2005)
- Telleman G, "The use of a coded healing abutment as an impression coping to design and mill an individualized anatomic abutment : a clinical report", J Prosthet Dent, 105, pp.282~285 (2011)
- Eliasson A, "The accuracy of an implant impression technique using digitally coded healing abutments", Clin Implant Dent Relat Res, 14(Suppl 1), pp.e30~e38 (2012)
- Al-Abdullah K, "An in vitro comparison of the accuracy of implant impressions with coded healing abutments and different implant angulations", J Prosthet Dent, 110, pp.90~100 (2013)
- Ng SD, "Three-dimensional accuracy of a digitally coded healing abutment implant impression system", Int J Oral Maxillofac Implants, 29, pp.927~936 (2014)
- Abduo J, "The effect of coded healing abutments on treatment duration and clinical outcome: a randomized controlled clinical trial comparing encode and conventional impression protocols", Int J Oral Maxillofac Implants (2017)
- Nayyar N, "Using digitally coded healing abutments and an intraoral scanner to fabricate implant-supported, cement-retained restorations", J Prosthet Dent, 109, pp.210~215 (2013)
- Vafiadis D, "Immediate implant placement of a single central incisor using a CAD", CAM crown-root form technique : provisional to final restoration, 2017, pp.29, 13~21
- Carpentieri JR, "A simplified impression protocol for fabrication of anatomical, cementretained CAD", CAM abutments, 2014, pp.34(Suppl 3), s19~s25
- Dhima M., "Correction of bone and softtissue deformity of the single implant in the aesthetic zone: a case treated with alveolar ridge preservation, modified roll technique and a digitally coded healing abutment", Eur J Prosthodont Restor Dent, 22, pp.51~55 (2014)
- Boeddinghaus M, "Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients", Clin Oral Investig, 19, pp.2027~2034 (2015)
- Papaspyridakos P, "Digital versus conventional implant impressions for edentulous patients: accuracy outcomes", Clin Oral Implants Res, 27, pp.465~472 (2016)
- Ueda K, "Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions", Clin Oral Investig, 20, pp.283~289 (2016)