본문 바로가기
KERD
논문KCI 등재

A Comparison of Scan Data Accuracy of Implant Scan Body and Encoded Healing Abutment

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: The precision of implant prostheses, which requires accurate impression acquisition, can significantly impact a patient’s treatment prognosis. This study therefore aimed to compare the accuracy of the scan data obtained using an encoded healing abutment with a scan body for digital implant impressions. Materials and Methods: A resin model was constructed using an implant analog (ISLA500, Neobiotech) at sites #15, #17, and #21. After the scan body was connected to on the model, it underwent scanning using a model scanner to produce reference data. The scan body (IS D5, Neobiotech) and encoded healing abutment (IS 4004S, Neobiotech) were connected to the model, and 20 scans per each group were performed using an intraoral scanner (Trios®, 3Shape Dental Systems). The data obtained from these two groups were compared with the reference data using two-way analysis of variance and t-tests. Results: The mean distance from the reference point was 0.089 mm in the scan body group and 0.217 mm in the encoded healing abutment group, indicating that the scan body was closer to the reference value than the encoded healing abutment. Conclusion: Digital implant impressions obtained with the scan body were more accurate than those acquired with the encoded healing abutment when taking digital implant impressions.

Abstract

Purpose: The precision of implant prostheses, which requires accurate impression acquisition, can significantly impact a patient’s treatment prognosis. This study therefore aimed to compare the accuracy of the scan data obtained using an encoded healing abutment with a scan body for digital implant impressions. Materials and Methods: A resin model was constructed using an implant analog (ISLA500, Neobiotech) at sites #15, #17, and #21. After the scan body was connected to on the model, it underwent scanning using a model scanner to produce reference data. The scan body (IS D5, Neobiotech) and encoded healing abutment (IS 4004S, Neobiotech) were connected to the model, and 20 scans per each group were performed using an intraoral scanner (Trios®, 3Shape Dental Systems). The data obtained from these two groups were compared with the reference data using two-way analysis of variance and t-tests. Results: The mean distance from the reference point was 0.089 mm in the scan body group and 0.217 mm in the encoded healing abutment group, indicating that the scan body was closer to the reference value than the encoded healing abutment. Conclusion: Digital implant impressions obtained with the scan body were more accurate than those acquired with the encoded healing abutment when taking digital implant impressions.

참고문헌 (20)

  1. Son YS, "The principles of dental implant prosthetics", pp.124~179 (2005), Charm Yoon Publishing
  2. Andreiotelli MK, "Digital data management for CAD", CAM technology. An update of current systems, 2013, pp.21, 9~15
  3. Leinfelder KF, "A new method for generating ceramic restorations : a CAD-CAM system", J Am Dent Assoc, 118, pp.703~707 (1989)
  4. Cabral LM, "Comparative analysis of 4 impression techniques for implants", Implant Dent, 16, pp.187~194 (2007)
  5. Daoudi MF, "An evaluation of three implant level impression techniques for single tooth implant", Eur J Prosthodont Restor Dent, 12, pp.9~14 (2004)
  6. Carr AB, "Comparison of impression techniques for a two-implant 15-degree divergent model", Int J Oral Maxillofac Implants, 7, pp.468~475 (1992)
  7. Goracci C, "Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions : a systematic review of the clinical evidence", Eur J Orthod, 38, pp.422~428 (2015)
  8. Wiranto MG, "Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions", Am J Orthod Dentofacial Orthop, 143, pp.140~147 (2013)
  9. Abrahamsson I, "The mucosal barrier following abutment dis", reconnection : an experimental study in dogs, 1997, pp.24, 568~572
  10. Kim YG, "The relationship between dental treatment and temporomandibular disorder", J Korean Dent Assoc, 46, pp.308~314 (2008)
  11. Abduo J, "The Effect of Coded Healing Abutments on Treatment Duration and Clinical Outcome : A Randomized Controlled Clinical Trial Comparing Encode and Conventional Impression Protocols", Int J Oral Maxillofac Implants, 32, pp.1172~1179 (2017)
  12. Oh KC, "A review of the digital impression taking technique of implants by using a coded healing abutment", Implantology, 21, pp.128~136 (2017)
  13. Del'Acqua MA, "Accuracy of impression techniques for an implant-supported prosthesis", Int J Oral Maxillofac Implants, 25, pp.715~721 (2010)
  14. Eliasson A, "The accuracy of an implant impression technique using digitally coded healing abutments", Clin Implant Dent Relat Res, 14, pp.e30~e38 (2012)
  15. Rutkūnas V, "Accuracy of digital implant impressions with intraoral scanners. A systematic review", Eur J Oral Implantol, 10, pp.101~120 (2017)
  16. Lee SJ, "Digital versus conventional implant impressions : efficiency outcomes", Clin Oral Implants Res, 24, pp.111~115 (2013)
  17. Kim KR, "Conventional open-tray impression versus intraoral digital scan for implant-level complete-arch impression", J Prosthet Dent, 122, pp.543~549 (2019)
  18. Flügge TV, "Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner", Am J Orthod Dentofacial Orthop, 144, pp.471~478 (2013)
  19. Giménez B, "Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth", Int J Oral Maxillofac Implants, 29, pp.853~862 (2014)
  20. Moreno A, "A clinical protocol for intraoral digital impression of screw-retained CAD", CAM framework on multiple implants based on wavefront sampling technology, 2013, pp.22, 320~325

관련 논문AI추천

Comparison of Accuracy in Digital Implant Impression using Dedicated and Compatible Scanbodies김준성, 손미경, 장근운, 허유리대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제1호Comparison of the accuracy of implant digital impression coping안교진, 이준석대한턱관절교합학회 · 구강회복응용과학지2020 · 제36권 제1호Effects of scan body material, length and top design on digital implant impression accuracy and usability: an in vitro studyAnn Wennerberg, Julian Hessel Baranowski, Michael Braian, Victoria Franke Stenport대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호스캔 힐링 어버트먼트를 이용한 임플란트 인상 채득법과 기존 임플란트 인상 채득법의 진실도 비교 연구권긍록, 김형섭, 노관태, 배아란, 백장현, 정권우, 홍성진대한치과보철학회 · 대한치과보철학회지2025 · 제63권 제1호코딩된 치유 지대주를 이용한 디지털 방식의 임플란트 인상채득 방법에 대한 고찰김종엽, 김종은, 심준성, 오경철대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2017 · 제21권 제2호Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluationsChuang Bi, Fangfang Tian, Jiaming Zhao, Xingyu Wang, Zhe Qu대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제4호

이 간행물의 다른 논문 (5건)