UFLC-MS/MS를 이용한 아미노산 분석방법 최적화
Optimization of Analytical Method for Amino Acids by Using UFLC-MS/MS
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Analytical conditions of amino acids in ground-water by using UFLC-MS/MS(ESI) were optimized for prompt and accurate analysis. Under the Edmen's method, derivatization of amino acids with PITC (phenylisothiocyanate)was performed and chromatographic separation was achieved on ODS (octadodesylsulfonate)-column with 3,400 psi. Within 10 minutes (6 min for MS collection), 21 types of amino acids were simultaneously analyzed by UFLC-MS/MS (ESI) after the selection of qualitative and quantitative ions. This method was precise with percent relative standard deviation of 2.6~13.8 % on 7 replicate analysis and accurate with percent recovery of 81.6~115.3 %. Confidence interval (CI, 3.53~4.25 mg/L). coefficient of determination (r^2, 0.970562 (TRP)~0.999329 (VAL)), limits of detection (0.29(PRO)~1.88(ASN) mg/L (mean. 0.91 mg/L)),and limits of quantification (0.99(PRO)~6.28(ASN) mg/L (mean, 3.03 mg/L)) were obtained and proven to be a reliable method. Derivatives was relatively stable when it occurred for more than three hours under 45oC based on optimum tests. Also, it was notable that m/z 164.15 ion, reagent of derivatization under MS/MS, was identified with phenylalanine in the same time frame, indicating excessive quantity. However, when the quantitative ion was changed from m/z 164.15 to m/z 221.10, relevant result was achieved.
Abstract
Analytical conditions of amino acids in ground-water by using UFLC-MS/MS(ESI) were optimized for prompt and accurate analysis. Under the Edmen's method, derivatization of amino acids with PITC (phenylisothiocyanate)was performed and chromatographic separation was achieved on ODS (octadodesylsulfonate)-column with 3,400 psi. Within 10 minutes (6 min for MS collection), 21 types of amino acids were simultaneously analyzed by UFLC-MS/MS (ESI) after the selection of qualitative and quantitative ions. This method was precise with percent relative standard deviation of 2.6~13.8 % on 7 replicate analysis and accurate with percent recovery of 81.6~115.3 %. Confidence interval (CI, 3.53~4.25 mg/L). coefficient of determination (r^2, 0.970562 (TRP)~0.999329 (VAL)), limits of detection (0.29(PRO)~1.88(ASN) mg/L (mean. 0.91 mg/L)),and limits of quantification (0.99(PRO)~6.28(ASN) mg/L (mean, 3.03 mg/L)) were obtained and proven to be a reliable method. Derivatives was relatively stable when it occurred for more than three hours under 45oC based on optimum tests. Also, it was notable that m/z 164.15 ion, reagent of derivatization under MS/MS, was identified with phenylalanine in the same time frame, indicating excessive quantity. However, when the quantitative ion was changed from m/z 164.15 to m/z 221.10, relevant result was achieved.
참고문헌 (13)
- "Merck Index, In 11th ed" (1989), Merck & Co., Inc
- T. Cserhati, "Chromatography of amino acid and short peptides", New advances, Biomed. Chromatogr, 21, pp.780~796 (2008)
- X. Wang, "Ultraperformance liquid chromatography coupled to mass spectrometry as a sensitive and powerful technology for metabolomic studies", J. Sep. Sci, 34, pp.3451~3459 (2011)
- M. Piraud, "ESI-MS", MS analysis of underivatised amino acids: a new tool for the diagnosis of inherited disorders of amino acid metabolism. Fragmentation study of 79 molecules of biological interest in positive and negative ionisation mode, 2003, pp.17, 1297~1311
- R. Checa-Moreno, "Revisitation of the phenylisothiocyanate- derivatives procedure for amino acid determination by HPLC-UV", J. Sep. Sci, 31, pp.3817~3828 (2008)
- R. L. Heinrikson, "Amino acid analysis by reverse-phase high-performance liquid chromatography : Precolumn derivatization with phenylisothiocyanate", Anal. Biochem, 136, pp.65~74 (1984)
- G. H. Jeffery, "Vogel's Textbook of quantitative chemical analysis, In 5th Ed. Ch. 4", pp.127~149 (1989)
- S. Dube, "Characterization of amino acids in silk sericin protein from Gonometa rufobrunnae by MEKC with phenyl isotihiocyanate derivatization", J. Sep. Sci, 29, pp.1245~1250 (2006)
- D. J. Dietzen, "Rapid comprehensive amino acid analysis by liquid chromatography", tandem mass spectrometry: comparison to cation exchange with post-column ninhydrin detection, 2008, pp.22, 3481~3488
- K. Shimbo, "Precolumn derivatization reagents for highspeed analysis of amines and amino acids in biological fluid using liquid chromatography", electrospray ionization tandem mass spectrometry, 2009, pp.23, 1438~1492
- Z. Liu, "Derivatization of amino acids with N,N-dimethyl-2,4-dinitro- 5-fluorobenzylamine for liquid chromatography", electrospray ionization mass spectrometry, 2004, pp.18, 1059~1065
- S. Inagaki, "Highly sensitive and positively charged precolumn derivatization reagent for amines and amino acids in liquid chromatography", electrospray ionization tandem mass spectrometry, 2010, pp.24, 1358~1364
- "Standard Method for water and wastewater, In 21th Ed. Ch.6", 6~78 (2005)