Endoscope Reprocessing: Update on Controversial Issues
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Several issues concerning endoscope reprocessing remain unresolved based on currently available data. Thus, further studies are required to confirm standard practices including safe endoscope shelf life, proper frequency of replacement of some accessories including water bottles and connecting tubes, and microbiological surveillance testing of endoscopes after reprocessing. The efficacy and cost-effectiveness of newer technology that allows automated cleaning and disinfection is one such controversial issue. In addition, there are no guidelines on whether delayed reprocessing and extended soaking may harm endoscope integrity or increase the bioburden on the external or internal device surfaces. In this review, we discuss the unresolved and controversial issues regarding endoscope reprocessing.
Abstract
Several issues concerning endoscope reprocessing remain unresolved based on currently available data. Thus, further studies are required to confirm standard practices including safe endoscope shelf life, proper frequency of replacement of some accessories including water bottles and connecting tubes, and microbiological surveillance testing of endoscopes after reprocessing. The efficacy and cost-effectiveness of newer technology that allows automated cleaning and disinfection is one such controversial issue. In addition, there are no guidelines on whether delayed reprocessing and extended soaking may harm endoscope integrity or increase the bioburden on the external or internal device surfaces. In this review, we discuss the unresolved and controversial issues regarding endoscope reprocessing.
참고문헌 (34)
- 이용국, "Steps of Reprocessing and Equipments", Clinical Endoscopy, 46(3), pp.274~279 (2013), 대한소화기내시경학회
- Petersen BT, "Multisociety guideline on reprocessing flexible gastrointestinal endoscopes: 2011", Gastrointest Endosc, 73, pp.1075~1084 (2011)
- Conner R, "Perioperative Standards and Recommended Practices", pp.405~419 (2010), AORN Inc
- Beilenhoff U, "ESGE-ESGENA Guideline: cleaning and disinfection in gastrointestinal endoscopy", Endoscopy, 40, pp.939~957 (2008)
- "Standards of infection control in reprocessing of flexible gastrointestinal endoscopes, 2012" (2015)[URL]
- Taylor A, "Infection Control in Gastrointestinal Endoscopy" (2010), Gastroenterological Society of Australia
- Alvarado CJ, "APIC guideline for infection prevention and control in flexible endoscopy. Association for Professionals in Infection Control", Am J Infect Control, 28, pp.138~155 (2000)
- 홍경희, "Recent Update of Gastrointestinal Endoscope Reprocessing", Clinical Endoscopy, 46(3), pp.267~273 (2013), 대한소화기내시경학회
- Alfa MJ, "Establishing a clinically relevant bioburden benchmark: a quality indicator for adequate reprocessing and storage of flexible gastrointestinal endoscopes", Am J Infect Control, 40, pp.233~236 (2012)
- Weber DJ, "Managing and preventing exposure events from inappropriately reprocessed endoscopes", Infect Control Hosp Epidemiol, 33, pp.657~660 (2012)
- Seoane-Vazquez E, "Endoscopy- related infections and toxic reactions: an international comparison", Endoscopy, 39, pp.742~746 (2007)
- Nelson DB, "Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy", World J Gastroenterol, 12, pp.3953~3964 (2006)
- Dirlam Langlay AM, "Reported gastrointestinal endoscope reprocessing lapses: the tip of the iceberg", Am J Infect Control, 41, pp.1188~1194 (2013)
- Ross AS, "A quarantine process for the resolution of duodenoscope-associated transmission of multidrug- resistant Escherichia coli", Gastrointest Endosc, 82, pp.477~483 (2015)
- Riley R, "Establishing the shelf life of flexible colonoscopes", Gastroenterol Nurs, 25, pp.114~119 (2002)
- Riley RG, "Extending the shelf-life of decontaminated flexible colonoscopes", J Gastroenterol Hepatol, 18, pp.1004~1005 (2003)
- Rejchrt S, "Bacteriologic testing of endoscopes after high-level disinfection", Gastrointest Endosc, 60, pp.76~78 (2004)
- Osborne S, "Challenging endoscopy reprocessing guidelines: a prospective study investigating the safe shelf life of flexible endoscopes in a tertiary gastroenterology unit", Endoscopy, 39, pp.825~830 (2007)
- Vergis AS, "Reprocessing flexible gastrointestinal endoscopes after a period of disuse: is it necessary?", Endoscopy, 39, pp.737~739 (2007)
- Ingram J, "Evaluation of medically significant bacteria in colonoscopes after 8 weeks of shelf life in open air storage", Gastroenterol Nurs, 36, pp.106~111 (2013)
- Brock AS, "Endoscope storage time: assessment of microbial colonization up to 21 days after reprocessing", Gastrointest Endosc, 81, pp.1150~1154 (2015)
- Bader L, "HYGEA (hygiene in gastroenterology: endoscope reprocessing): study on quality of reprocessing flexible endoscopes in hospitals and in the practice setting", Z Gastroenterol, 40, pp.157~170 (2002)
- Doherty DE, "Pseudomonas aeruginosa sepsis following retrograde cholangiopancreatography (ERCP)", Dig Dis Sci, 27, pp.169~170 (1982)
- Society of Gastroenterology Nurses and Associates, Inc, "SGNA position statement: reprocessing of water bottles used during endoscopy", Gastroenterol Nurs, 33, pp.81~82 (2010)
- Desilets D, "Automated endoscope reprocessors", Gastrointest Endosc, 72, pp.675~680 (2010)
- Bisset L, "A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure", Am J Infect Control, 34, pp.274~280 (2006)
- Pajkos A, "Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination?", J Hosp Infect, 58, pp.224~229 (2004)
- Alfa MJ, "EVOTECH endoscope cleaner and reprocessor (ECR) simulated-use and clinical-use evaluation of cleaning efficacy", BMC Infect Dis, 10, pp.200~ (2010)
- Rutala WA, "New developments in reprocessing semicritical items", Am J Infect Control, 41(5), pp.S60~S66 (2013)
- Forte L, "Comparative cost-efficiency of the EVOTECH endoscope cleaner and reprocessor versus manual cleaning plus automated endoscope reprocessing in a real-world Canadian hospital endoscopy setting", BMC Gastroenterol, 11, pp.105~ (2011)
- Agrawal D, "Delayed reprocessing of endoscopes", Gastrointest Endosc, 73, pp.853~854 (2011)
- "Avoiding reprocessing errors critical for infection prevention and control 2005" (2015)[URL]
- Alfa MJ, "Modeling microbial survival in buildup biofilm for complex medical devices", BMC Infect Dis, 9, pp.56~ (2009)
- Muthiah KC, "A survey of the practice of after-hours and emergency endoscopy in Canada", Can J Gastroenterol, 26, pp.871~876 (2012)