Analysis of stress distribution of tooth restored with metal-ceramic crown covering abfraction lesion according to its finish line location under occlusal load
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
When the full veneer crown was treated in the tooth with abfraction lesion due to various causes, the prognosis of it may be compromised according to the location of the finish line, but there is few study about the location of its buccal finish line. The purpose of this study was to investigate the effect of location of the finish line of the full veneer crown on stress distribution of the tooth with abfraction lesion. Materials and methods: The two dimensional finite element model was developed to express tooth, surrounding tissue and full veneer crown. The stress distribution under eccentric 144 N occlusal load was analyzed using finite element analysis. The location of finish line was set just at the lower border of the lesion (Group 0), 1 mm (Group 1) and 2 mm (Group 2) below the lower border of the lesion. Results: In the Group 0, von Mises stress was concentrated at the finish line and the apex of the lesion. Also, the stress at the bucal finish line propagated to the lingual side. In the Group 1 and Group 2, stress distribution was similar each other. Stress was concentrated at the apex of lesion, but the stress at the buccal finish line did not propagate to the lingual side. That implied decrease of the possibility of horizontal crown fracture. Conclusion: Full veneer crown alleviated the stress concentrated at the apex of the abfraction lesion, when the finish line of full veneer crown was set below the lower border of abfraction lesion.
Abstract
When the full veneer crown was treated in the tooth with abfraction lesion due to various causes, the prognosis of it may be compromised according to the location of the finish line, but there is few study about the location of its buccal finish line. The purpose of this study was to investigate the effect of location of the finish line of the full veneer crown on stress distribution of the tooth with abfraction lesion. Materials and methods: The two dimensional finite element model was developed to express tooth, surrounding tissue and full veneer crown. The stress distribution under eccentric 144 N occlusal load was analyzed using finite element analysis. The location of finish line was set just at the lower border of the lesion (Group 0), 1 mm (Group 1) and 2 mm (Group 2) below the lower border of the lesion. Results: In the Group 0, von Mises stress was concentrated at the finish line and the apex of the lesion. Also, the stress at the bucal finish line propagated to the lingual side. In the Group 1 and Group 2, stress distribution was similar each other. Stress was concentrated at the apex of lesion, but the stress at the buccal finish line did not propagate to the lingual side. That implied decrease of the possibility of horizontal crown fracture. Conclusion: Full veneer crown alleviated the stress concentrated at the apex of the abfraction lesion, when the finish line of full veneer crown was set below the lower border of abfraction lesion.
참고문헌 (15)
- Grippo JO, "Abfractions: a new classification of hard tissue lesions of teeth", J Esthet Dent, 3, pp.14~19 (1991)
- Lee WC, "Possible role of tensile stress in the etiology of cervical erosive lesions of teeth", J Prosthet Dent, 52, pp.374~380 (1984)
- Rees JS, "The effect of variation in occlusal loading on the development of abfraction lesions: a finite element study", J Oral Rehabil, 29, pp.188~193 (2002)
- Francisconi LF, "The effects of occlusal loading on the margins of cervical restorations", J Am Dent Assoc, 140, pp.1275~1282 (2009)
- Ichim I, "Mechanical evaluation of cervical glass-ionomer restorations: 3D finite element study", J Dent, 35, pp.28~35 (2007)
- Grippo JO, "Noncarious cervical lesions: the decision to ignore or restore", J Esthet Dent, 4, pp.55~64 (1992)
- Rosenstiel SF, "Contemporary fixed prosthodontics", pp.868~ (2001), Mosby
- Rubin C, "Stress analysis of the human tooth using a three-dimensional finite element model", J Dent Res, 62, pp.82~86 (1983)
- Rees JS, "Modelling the effects of enamel anisotropy Yaman SD, Alaçam T, Yaman Y. Analysis of stress distribution in a maxillary central incisor subjected to various post and core applications", J Endod, 24, pp.107~111 (1998)
- Versluis A, "Does an incremental filling technique reduce polymerization shrinkage stresses?", J Dent Res, 75, pp.871~878 (1996)
- Palamara D, "Strain patterns in cervical enamel of teeth subjected to occlusal loading", Dent Mater, 16, pp.412~419 (2000)
- Sorensen JA, "Ferrule design and fracture resistance of endodontically treated teeth", J Prosthet Dent, 63, pp.529~536 (1990)
- Rees JS, "Elastic modulus of the periodontal ligament", Biomaterials, 18, pp.995~999 (1997)
- Vincent JFV, "Structural biomaterials", pp.244~ (1990), Princeton University Press
- Lewinstein I, "Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis", Int J Oral Maxillofac Implants, 10, pp.355~366 (1995)
