초록

Indoor air pollution has become a serious issue, affecting the health and comfort of building occupants. Volatile organic compounds (VOCs) are among the most common indoor contaminants, and are released from numerous indoor emission sources. Among the VOCs, formaldehyde and toluene are toxic chemicals at low levels and are frequently detected indoors. Exposure to formaldehyde and toluene can irritate sensitive tissue and may increase the risk of cancer. Therefore, monitoring formaldehyde and toluene is critical for the health and comfort of residents. In addition, as human indoor activities can gen- erate VOC gases, analysis of their influence on VOCs is needed. In this study, we compared electronic nose (E-Nose) data for formaldehyde and toluene with E-Nose data for indoor mixture gas with consideration for human indoor activities.

Abstract

Indoor air pollution has become a serious issue, affecting the health and comfort of building occupants. Volatile organic compounds (VOCs) are among the most common indoor contaminants, and are released from numerous indoor emission sources. Among the VOCs, formaldehyde and toluene are toxic chemicals at low levels and are frequently detected indoors. Exposure to formaldehyde and toluene can irritate sensitive tissue and may increase the risk of cancer. Therefore, monitoring formaldehyde and toluene is critical for the health and comfort of residents. In addition, as human indoor activities can gen- erate VOC gases, analysis of their influence on VOCs is needed. In this study, we compared electronic nose (E-Nose) data for formaldehyde and toluene with E-Nose data for indoor mixture gas with consideration for human indoor activities.

참고문헌 (14)

  1. A. P. Jones, "Indoor air quality and health", Atmos. Environ., 33(28), pp.4535~4564 (1999)[DOI]
  2. J. Sundell, "On the history of indoor air quality and health", Indoor Air, 14(7), pp.51~58 (2004)
  3. Y. Huang, "Removal of indoor volatile organic compounds via photocatalytic oxidation: a short review and prospect", Molecules, 21(1), pp.1~20 (2016)
  4. C. S. Mitchell, "Current state of the science: health effects and indoor environmental quality", Environ. Health Perspect., 115(6), pp.958~964 (2007)[DOI]
  5. J. E. McNary, "Inhalation exposure to formaldehyde and toluene in the same occupational and consumer setting", Inhal. Toxicol., 19(6-7), pp.573~576 (2007)[DOI]
  6. T. Salthammer, "Formaldehyde in the indoor environment", Chem. Rev., 110(4), pp.2536~2572 (2010)[DOI]
  7. H. Eom, "Inhalation toxicity of indoor air pollutants in Drosophila melanogaster using integrated transcriptomics and computational behavior analyses", Sci. Rep., 7, pp.1~15 (2017)[DOI]
  8. A. Clobes, "Human activities as sources of volatile organic compounds in residential environments", Ann. N. Y. Acad. Sci., 641(1), pp.79~86 (1992)[DOI]
  9. N. Bruce, "Indoor air pollution in developing countries: a major environmental and public health challenge", Bull. World Health Organ., 78(9), pp.1078~1092 (2000)
  10. C. Rosch, "Relationship between sources and patterns of VOCs in indoor air", Atmos. Pollution Research, 5(1), pp.129~137 (2014)[DOI]
  11. P Pluschke, "Indoor air pollution", pp.4~ (2018), Springer
  12. "법령", 실내공기질관리법시행규칙, ~