다양한 실내환경 중 휘발성유기화합물 오염의 패턴 분류
Pattern Classification of Volatile Organic Compounds in Various Indoor Environment
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June, 2005 to May, 2006. Concentration of TVOCs in maternity recuperations was 2,605.7g/m3 that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6g/m3 also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5g/m3, in only public childcare centers exceeded the 120g/m3 of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4g/m3 and 184.9g/m3, respectively.
Abstract
The purpose of this study was to survey the distribution patterns of volatile organic compounds(VOCs) and formaldehyde in the various indoor environments using cluster analysis. We investigated VOCs and formaldehyde in subway stations, underground shopping areas, medical centers, maternity recuperation centers, public childcare centers, large stores, funeral houses, and indoor parking lots from June, 2005 to May, 2006. Concentration of TVOCs in maternity recuperations was 2,605.7g/m3 that was higher than the guideline and other facilities. TVOCs in public childcare centers was 1,951.6g/m3 also it exceeded the guideline. Moreover, concentration of TVOCs in every facility exceeded the guideline of Department of Environment, Korea. In case of formaldehyde, mean concentration, 336.5g/m3, in only public childcare centers exceeded the 120g/m3 of the guideline. Finally, by applying cluster analysis, three pattterns of the indoor air pollutions were distinguished. In the results of analysis, concentrations of TVOCs and formaldehyde of cluster 3 were higher than cluster 1 and 2 that were 2,561.4g/m3 and 184.9g/m3, respectively.
참고문헌 (13)
- "Risk assessment of acute health and comfort effects of indoor air pollution Annals of the New York Academy of Sciences", pp.56~62 (1992)
- "National Academy of Sciences Human Exposure Assessment for Airborne Pollutants" (1993)
- "Indoor and outdoor air quality investigation at school in Hong Kong", 40, pp.109~112 (2000)
- "An engineering approach to controlling indoor air quality", pp.15~21 (1991)
- "Evaluating sources of indoor air pollution", pp.487~492 (1990)
- "Modeling of indoor exposure to nitrogen dioxide in the UK", 35, pp.269~279 (2005)
- "분산주성분 분석을 이용한 실내환경 중 PM-10 오염의 패턴분류", 18(1), pp.25~37 (2002)
- "PMF 방법론을 이용한 수원지역 PM-10의 오염원 확인", 17(2), pp.133~145 (2001)
- "군집분석과 분산 주성분분석법을 이용한 대기분진시료의 분류", 13(1), pp.51~63 (1997)
- "Receptor Modeling in Environmental Chemistry" (1985)
- "Pattern Recognition을 이용한 지하상가에서의 대기오염물질의 농도 분석에 관한 연구", pp.1~10 (1990)
- "Receptor Modeling for Air Quality Management" (1991), Elsevier Science Publishing Company Inc