안정동위원소 비 측정을 위한 MC-ICP/MS 성능 평가 연구
Study on Performance Evaluation of MC-ICP/MS for measuring Stable Isotope Ratios
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
This study was conducted to evaluate the performance of the MC-ICP/MS by using some standard metals to test five items such as sensitivity, mass resolving power, detector noise, mass stability and precision of iso-tope ratios. The sensitivities ranged from 148 to 578 Vppm -1in the dry plasma system. The sensitivities were improved as much as 1.2~2.5 times those of previous studies. The resolution (M/∆M) at 10% peak height was as high as 8352 for 142Nd. The mass drift was 30 ppm of the peak range during the 30-minute measurement. Such high resolution and mass stability made it possible to separate purposed analytes from polyatomic inter-ferents more effectively. The noise levels of faraday detectors (1.5~2.7×10-5V) and ion counting multipliers (0.01~0.1 cps) were well below the performance standard. Analyzing the isotope ratios of Li, Sr, Nd, Pb and U standard solutions showed that all but Li isotope ratios were in good agreement with those reported in the previous studies. In conclusion, this study may build a new foundation for environmental research by sug-gesting the use of isotope ratios to trace heavy metal sources and estimate their contributions, which will over-come limitations in the existing methods of residual investigation and modeling.
Abstract
This study was conducted to evaluate the performance of the MC-ICP/MS by using some standard metals to test five items such as sensitivity, mass resolving power, detector noise, mass stability and precision of iso-tope ratios. The sensitivities ranged from 148 to 578 Vppm -1in the dry plasma system. The sensitivities were improved as much as 1.2~2.5 times those of previous studies. The resolution (M/∆M) at 10% peak height was as high as 8352 for 142Nd. The mass drift was 30 ppm of the peak range during the 30-minute measurement. Such high resolution and mass stability made it possible to separate purposed analytes from polyatomic inter-ferents more effectively. The noise levels of faraday detectors (1.5~2.7×10-5V) and ion counting multipliers (0.01~0.1 cps) were well below the performance standard. Analyzing the isotope ratios of Li, Sr, Nd, Pb and U standard solutions showed that all but Li isotope ratios were in good agreement with those reported in the previous studies. In conclusion, this study may build a new foundation for environmental research by sug-gesting the use of isotope ratios to trace heavy metal sources and estimate their contributions, which will over-come limitations in the existing methods of residual investigation and modeling.
참고문헌 (17)
- 김규한, "동위원소지구화학", pp.4~12 (2010), 시그마프레스
- M. Baskaran, "Handbook of Environmental Isotope Geochemistry", pp.951~ (2011), springer
- D. L. Phillips, , Ocecologia, 136, pp.261~269 (2003)
- 국립환경과학원, "MC-ICP", MS를 이용한 환경동위원소 분석 핸드북, 2012, pp.124~
- F. Albarède, , Reviews in Mineralogy & Geochemistry, 55, pp.113~152 (2004)
- H. C. Liu, , Talanta, 88, pp.338~344 (2012)
- A. Cocherie, , Chemical Geology, 243, pp.90~104 (2007)
- M. E. Sánchez-Lorda, , International Journal of Mass Spectrometry, 333, pp.33~43 (2013)
- R. M. Wang, , Talanta, 107, pp.67~73 (2013)
- S. Weyer, , International Journal of Mass Spectrometry, 226, pp.355~368 (2003)
- M. E. Wieser, , International Journal of Mass Spectrometry, 242, pp.97~115 (2005)
- M. R. M. D. Van Acker, , Anal. Chem, 78, pp.4663~4667 (2006)
- L. Yang, , Mass Spectrometry Reviews, pp.990~1011 (2009)
- T. Miyazaki, , Geochemical Journal, 32, pp.345~350 (1998)
- A. A. G. Srinivasan, , International Journal of Mass Spectrometry, 299, pp.27~34 (2011)
- T. Tanaka, "Abstract Japan Earth and planet", Sci. Joint. Meeting, pp.455~ (1997)
- M. Berglund, , Pure Appl. Chem, 83, pp.397~410 (2011)