본문 바로가기
KERD
논문KCI 등재

원소분석기와 연계된 동위원소질량분석기(EA-IRMS)를 이용한 탄소안정동위원소비 정확도·정밀도 연구

The Study on Accuracy and Precision of Carbon Isotope Using Elemental Analyzer-Isotope Ratio Mass Spectrometer (EA-IRMS)

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

The reproducibility as the standard deviation or standard error of analytical data is used to estimate the performance ability of the isotope ratio mass spectrometer (IRMS). The standard deviation of δ^13C value of a sample is not supposed to be the same on a wide range of sample weights. In order to determine the suitable sample amounts required for high precision and accuracy and the factors required for optimal equipment conditions,certified reference materials were repeatedly measured with various weight ranges using an elemental analyzerisotope ratio mass spectrometer (EA-IRMS). The measured δ^13C values of the standards EMA-P1 and EMAP2fell within the certified value ±2σ with the minimum carbon contents of 102.107 μg and 116.879 μg,respectively. In addition, for the two standards, the peak height ratios calculated by the CO_2(^12C^16O^16O) peak height of the sample to the working standard were 62.8% and 66.8%, respectively. The isotopic composition change was also investigated by the fractionation factor ε_applied and did not show a large difference in a wide range of sample weight for the two standards. We suggest that carbon isotope composition needs to be determined by considering several factors such as element contents, standard deviation of δ^13C value, peak height ratio(or peak height) and fractionation factor ε_applied.

Abstract

The reproducibility as the standard deviation or standard error of analytical data is used to estimate the performance ability of the isotope ratio mass spectrometer (IRMS). The standard deviation of δ^13C value of a sample is not supposed to be the same on a wide range of sample weights. In order to determine the suitable sample amounts required for high precision and accuracy and the factors required for optimal equipment conditions,certified reference materials were repeatedly measured with various weight ranges using an elemental analyzerisotope ratio mass spectrometer (EA-IRMS). The measured δ^13C values of the standards EMA-P1 and EMAP2fell within the certified value ±2σ with the minimum carbon contents of 102.107 μg and 116.879 μg,respectively. In addition, for the two standards, the peak height ratios calculated by the CO_2(^12C^16O^16O) peak height of the sample to the working standard were 62.8% and 66.8%, respectively. The isotopic composition change was also investigated by the fractionation factor ε_applied and did not show a large difference in a wide range of sample weight for the two standards. We suggest that carbon isotope composition needs to be determined by considering several factors such as element contents, standard deviation of δ^13C value, peak height ratio(or peak height) and fractionation factor ε_applied.

참고문헌 (23)

  1. O. Schmidt, , Food Chemisty, 91, pp.545~549 (2005)
  2. G. F. Pang, , Journal of the Science of Food and Agriculture, 86, pp.315~319 (2006)
  3. J. R. Ehleringer, , Forensic Science International, 106, pp.27~35 (1999)
  4. R. Santamaria-Fernandez, , Science and Justice, 49, pp.102~106 (2009)
  5. E. Mützel, , International Journal of Legal Medicine, 123, pp.35~40 (2009)
  6. R. Serrano, , Science of the Total Environment, 389, pp.340~349 (2008)
  7. K. H. Elliott, , Science of the Total Environment, 407, pp.3867~3875 (2009)
  8. V. P. O'Malley, , Organic Geochemisty, 27, pp.567~581 (1997)
  9. M. Kim, , Science of the Total Environment, 389, pp.367~377 (2008)
  10. C. E. Jonsson, , Journoa of Hydrology, 376, pp.143~151 (2009)
  11. A. K. Henderson, , Earth and Planetary Science Letters, 300, pp.205~214 (2010)
  12. N. M. Kortelainen, , Journal of Hydrology, 285, pp.143~157 (2004)
  13. D. Xue, , Water Research, 43, pp.1159~1170 (2009)
  14. B. Shormar, , Science of the Total Environment, 389, pp.164~174 (2008)
  15. K. S. Lee, , Science of the Total Environment, 395, pp.117~124 (2008)
  16. M. Itoh, , Science of the Total Environment, 409, pp.1530~1538 (2011)
  17. C. Fenech, , Water Research, 46, pp.2023~2041 (2012)
  18. I. C. Torres, , Journal of Paleolimnology, 47, pp.693~706 (2012)
  19. S. Aguiñiga, , Continental Shelf Research, 30, pp.1692~1700 (2010)
  20. M. A. Goni, , Estuarine Coastal and Shelf Science, 69, pp.225~245 (2006)
  21. F. Hyodo, , Science of the Total Environment, 403, pp.139~147 (2008)
  22. L. Marín-Guirao, , Science of the Total Environment, 393, pp.118~ (2008)
  23. N. V. Grassineau, , Applied Geochemistry, 21, pp.756~765 (2006)

관련 논문AI추천

원소분석기와 연계된 동위원소질량분석기(EA-IRMS)를 이용한 질소안정동위원소비 측정의 정확도·정밀도 연구김민섭, 김보경, 이상욱, 이원석, 황종연한국환경분석학회 · 환경분석과 독성보건2013 · 제16권 제1호Inter-laboratory Comparison of Stable Carbon and Nitrogen Isotopic Composition Data Using Elemental Analyzer-isotope Ratio Mass Spectrometers강수진, 강태우, 김다해, 김정현, 남승일, 박광규, 박용세, 봉연식, 신경훈, 이상모, 주영지, 최보형, 최승현한국환경분석학회 · 환경분석과 독성보건2018 · 제21권 제4호안정동위원소 비 측정을 위한 MC-ICP/MS 성능 평가 연구김종대, 유은진, 이강현, 이원석, 최종우, 한진석한국환경분석학회 · 환경분석과 독성보건2013 · 제16권 제1호EA-IRMS를 이용한 HCB와 PeCB 표준물질 탄소동위원소 분석 연구김기준, 김보경, 김영희, 박광수, 박진주, 석광설, 이진선, 최경희한국환경분석학회 · 환경분석과 독성보건2013 · 제16권 제3호용존유기탄소의 δ13 C 분석시 고형화 전처리 방법 비교: 알칼린 과황산칼륨산화-탄산침전과 동결건조박용세, 박현진, 윤광식, 이상모, 전병준, 최우정한국환경농학회 · 한국환경농학회지2017 · 제36권 제2호다중 검출 유도결합 플라즈마 질량분석기를 이용한 납 및 카드뮴안정동위원소비 분석의 질량 편향 보정방법 비교권오상, 김명진, 김지영, 유은진, 이강현, 이경석, 이원석, 최종우한국환경분석학회 · 환경분석과 독성보건2014 · 제17권 제3호

이 간행물의 다른 논문 (10건)