다중 검출 유도결합 플라즈마 질량분석기를 이용한 납 및 카드뮴안정동위원소비 분석의 질량 편향 보정방법 비교

Comparison of Mass Bias Correction Methods for Lead and Cadmium Stable Isotope Analysis by Multi-Collector ICP-MS

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

To obtain precise and accurate isotope ratios with a multi-collector ICP-MS, three methods such as interelementalinternal calibration, sample-standard bracketing (SSB), and log-log linear regression correctionmodel were applied to isotope ratio measurement of lead (Pb) and cadmium (Cd) for the correction of instrumentalmass discrimination. Certified reference materials including NIST SRM 981 (Pb), NIST SRM 3108(Cd), and BAM I012 (Cd) were used as reference materials for the isotope ratios of lead and cadmium to comparethe corrected results obtained from the respective correction models. The accuracies of lead isotope ratiomeasurements were in the range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % when the inter-elementalinternal calibration applied. The same range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % was also found withthe SSB method. The log-log linear regression correction model, on the other hand, showed a differentrange of -2.160 (207/206Pb) to 0.219 (208/204Pb) %. The precisions of lead isotope ratios with these three correctionmethods ranged from 0.027 (206/204Pb) to 0.127 (208/204Pb), 0.025 (206/204Pb) to 0.124 (208/204Pb), and1.265 (207/204Pb) to 1.367 (207/206Pb), respectively. Therefore, both of the inter-elemental internal calibrationand the SSB method were selected as good methods for mass bias correction of lead isotope ratios. Theε114/110Cd values obtained from the application of the three different correction models were -14.5±0.7 (Agas an internal standard), -13.0±2.1 (SSB), and -15.2±1.8 (log-log linear regression correction model),respectively. For ε114/110Cd values, the inter-elemental internal calibration showed the best precisionamong the three correction methods. Isobaric interferences with cadmium were also corrected when correctioncoefficients were applied to each isotope of cadmium. The difference of correction coefficientsbetween the isotope ratios with natural abundances and the empirical ratios in the isobaric interferencesreached up to 11%. The heavier isobaric interferences (106, 108, 110Pd vs. 105Pd) were underestimated in theapplication of the natural ratios, while the lighter isobaric interferences (112,114,116Sn vs. 118Sn and113In vs. 115In) were overestimated. In conclusion, the inter-elemental internal calibration and the SSB method canproperly correct the isotope ratios of interest in the isotope ratio measurement using the MC-ICP-MS. Further research on the isotope ratio analysis of environmental samples should follow to improve precisionand accuracy.

Abstract

To obtain precise and accurate isotope ratios with a multi-collector ICP-MS, three methods such as interelementalinternal calibration, sample-standard bracketing (SSB), and log-log linear regression correctionmodel were applied to isotope ratio measurement of lead (Pb) and cadmium (Cd) for the correction of instrumentalmass discrimination. Certified reference materials including NIST SRM 981 (Pb), NIST SRM 3108(Cd), and BAM I012 (Cd) were used as reference materials for the isotope ratios of lead and cadmium to comparethe corrected results obtained from the respective correction models. The accuracies of lead isotope ratiomeasurements were in the range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % when the inter-elementalinternal calibration applied. The same range of -0.002 (207/206Pb) to -0.035 (208/204Pb) % was also found withthe SSB method. The log-log linear regression correction model, on the other hand, showed a differentrange of -2.160 (207/206Pb) to 0.219 (208/204Pb) %. The precisions of lead isotope ratios with these three correctionmethods ranged from 0.027 (206/204Pb) to 0.127 (208/204Pb), 0.025 (206/204Pb) to 0.124 (208/204Pb), and1.265 (207/204Pb) to 1.367 (207/206Pb), respectively. Therefore, both of the inter-elemental internal calibrationand the SSB method were selected as good methods for mass bias correction of lead isotope ratios. Theε114/110Cd values obtained from the application of the three different correction models were -14.5±0.7 (Agas an internal standard), -13.0±2.1 (SSB), and -15.2±1.8 (log-log linear regression correction model),respectively. For ε114/110Cd values, the inter-elemental internal calibration showed the best precisionamong the three correction methods. Isobaric interferences with cadmium were also corrected when correctioncoefficients were applied to each isotope of cadmium. The difference of correction coefficientsbetween the isotope ratios with natural abundances and the empirical ratios in the isobaric interferencesreached up to 11%. The heavier isobaric interferences (106, 108, 110Pd vs. 105Pd) were underestimated in theapplication of the natural ratios, while the lighter isobaric interferences (112,114,116Sn vs. 118Sn and113In vs. 115In) were overestimated. In conclusion, the inter-elemental internal calibration and the SSB method canproperly correct the isotope ratios of interest in the isotope ratio measurement using the MC-ICP-MS. Further research on the isotope ratio analysis of environmental samples should follow to improve precisionand accuracy.

참고문헌 (16)

  1. F. Albarède, "Precise and accurate isotopic measurements using multiple-collector ICPMS", Geochimica et Cosmochimica Acta, 68, pp.2725~2744 (2004)
  2. P. B. Tomascak, "Accurate and precise determinations of Li isotopic composition by multi-collector sector ICP-MS", Chemical geology, 158, pp.145~154 (1999)
  3. A. J. Walder, "Isotopic ratio measurement using a double focusing magnetic sector analyser with an inductively coupled plasma as an ion source", Journal of analytical atomic Spectrometry, 7, pp.571~575 (1992)
  4. A. J. Walder, "high-precision lead isotope ratio measurement by inductively coupled plasma multi-collector mass spectrometry", Analytical sciences, 9, pp.675~680 (1993)
  5. W. M. White, "High-precision analysis of Pb isotope ratios by multi-collector ICP-MS", Chemical Geology, 167, pp.257~270 (2000)
  6. D. Vance, "An assessment of mass discrimination in MC-ICPMS using Nd isotopes", Chemical Geology, 185, pp.227~240 (2002)
  7. N. S. Belshaw, "High precision measurement of iron isotopes by plasma source mass spectrometry", International Journal of Mass Spectrometry, 197, pp.191~195 (2000)
  8. M. Rehkämper, "Accuracy and longterm reproducibility of lead isotopic measurements by multiple-collector inductively coupled plasma mass spectrometry using an external method for correction of mass discrimination", International Journal of Mass Spectrometry, 181, pp.123~133 (1998)
  9. C. N. Maréchal, "Precise anallysis of copper and zinc isotopic compositios by plasma-source mass spectrometry", Chemical Geology, 156, pp.251~273 (1999)
  10. A. Cocherie, "Direct mesurement of lead isotope ratios in low concentration environmental sample by MC-ICP-MS and multi-ion counting", Chemical Geology, 243, pp.90~104 (2007)
  11. S. Ripperger, "Precise determination of cadmium isotope raction in seawater by double spike MC-ICPMS", Geochimica et Cosmochimica Acta, 71, pp.631~642 (2007)
  12. W. Abouchami, "A common reference material for cadmium isotope studies - NIST SRM 3108", Geostandads and geoanalytical research, 37(1), pp.5~17 (2012)
  13. L. Yang, "Use of Zr for mass bias correction in strontium isotope ratio determinations using MC-ICP-MS", Journal of Analytical Atomic Spectrometry, 23, pp.1269~1274 (2008)
  14. J. Meija, "Mass Bias Fractionation Laws for Multi-Collector ICPMS : Assumptions and Their Experimental Verification", Analytical Chemistry, 81, pp.6774~6778 (2009)
  15. F. Albarède, "Analytical method for nontraditional isotopes", Reviews in Mineralogy and Geochemistry, 55, pp.113~152 (2004)
  16. A. J. Pietruszka, "Identification of a matrix effect in the MC-ICP-MS due to sample purification using ion exchange resin: An isotopic case study of molybdenium", International Journal of Mass Spectrometry, 270, pp.23~30 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (6건)