본문 바로가기
KERD
논문KCI 미등재

전자토모그래피의 정량적 분석에서 대물렌즈 조리개의 영향

Objective Aperture Effects for the Quantitative Analysis in Electron Tomography

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류자연과학일반

초록

We have evaluated the effects of experimental factors on transmitted electron beam intensities for quantitative analysis in electron tomography. For the correct application of Beer’s law in electron tomography, the transmitted beam intensity should reflect the net effect of mass properties on beam path. So, the any other effects of the objective aperture and the specimen holder on beam path should be removed. The cut-off effects of objective aperture were examined using Quantifoil holey carbon film and a transmission electron microscope operated at 120 kV. The transmitted beam intensities with 30 μm objective aperture dropped about 16.7% compared to electron beam intensities without the objective aperture. Also, the additional losses of about 14.2% at high tilt angles were occurred by cut-off effects of the objective apertures. For the precise quantitative analysis in electron tomography, the effect of the objective aperture on transmitted electron beam intensities should be considered. It is desirable that 2-D tilt series images are obtained without the objective aperture for correct application of Bee’s law.

Abstract

We have evaluated the effects of experimental factors on transmitted electron beam intensities for quantitative analysis in electron tomography. For the correct application of Beer’s law in electron tomography, the transmitted beam intensity should reflect the net effect of mass properties on beam path. So, the any other effects of the objective aperture and the specimen holder on beam path should be removed. The cut-off effects of objective aperture were examined using Quantifoil holey carbon film and a transmission electron microscope operated at 120 kV. The transmitted beam intensities with 30 μm objective aperture dropped about 16.7% compared to electron beam intensities without the objective aperture. Also, the additional losses of about 14.2% at high tilt angles were occurred by cut-off effects of the objective apertures. For the precise quantitative analysis in electron tomography, the effect of the objective aperture on transmitted electron beam intensities should be considered. It is desirable that 2-D tilt series images are obtained without the objective aperture for correct application of Bee’s law.

참고문헌 (10)

  1. Danev R, "Single particle analysis based on zernike phase contrast microscopy", J Struct Biol, 161, pp.211~218 (2008)
  2. DeRosier DJ, "Reconstruction of three dimensional struc-tures from electron micrographs", Nature, 217, pp.130~134 (1968)
  3. Friedricha H, "Comparison of intensity distributions in tomograms from BFTEM, ADFSTEM, HAADFSTEM, and calculated tilt series", Ultramicroscopy, 106, pp.18~27 (2005)
  4. Hart RG, "Electron microscopy of unstained biological material: the polytropic montage", Science, 159, pp.1464~1467 (1968)
  5. 주형태, "영상 자료 획득시의 오류가 전자토모그래피 결과에 미치는 영향 고찰-모델 시뮬레이션을 중심으로", 한국현미경학회지, 38(1), pp.51~61 (2008), 한국현미경학회
  6. 김진규, "3차원적 구조분석을 위한 TEM Rotation Holder의신뢰도 점검", 한국현미경학회지, 36(3), pp.209~216 (2006), 한국현미경학회
  7. Midgley PA, "3D electron microscopy in the physical sciences: the development of Z-contrast and EFTEM tomography", Ultramicroscopy, 96, pp.413~431 (2003)
  8. Pozsgai I, "Thickness determination by measuring electron transmission in the TEM at 200 kV", Ultramicroscopy, 68, pp.69~75 (1997)
  9. Radon J, , Ber. Verh. K. Sachs. Ges. Wiss. Leipzig Math. Phys. Kl, 69, pp.262~ (1917)
  10. Williams DB, "Transmission Electron Microscopy-A Textbook for Materials Science", pp.69~83 (1995), Plenum Press

관련 논문AI추천