경골 내 변형률 및 응력 분포 특성 분석을 통한 새로이 개발된 재치환용 인공슬관절의 생체역학적 안정성 평가: 유한요소해석
Evaluation of Biomechanical Stability of Newly Developed Revision Total Knee Arthroplasty through Strain and Stress Distribution Analysis within the Tibia: Finite Element Analysis
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp.,Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling,leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.
Abstract
In this study, biomechanical stability of the newly developed revision total knee arthroplasty (rTKA) was evaluated through strain and stress distribution analysis within the implanted proximal tibia using a three-dimensional finite element (FE) analysis. 2000N of compressive load (about 3 times body weight) was applied to the condyle surface on spacer, sharing by the medial (60%) and lateral (40%) condyles simulating a stance phase before toe-off. The results showed that PVMS within the revision total knee arthroplasty and the proximal tibia were less than yield strength considering safe factor 4.0 (rTKA: less than 10%, Cortical bone: less than 70%, Cancellous bone: less than 70%). The materials composed of them and the strain and stress distributions within the proximal tibia were generally well matched with those of a traditional revision total knee arthoplasty (Scorpio TS revision system, Stryker Corp.,Michigan, USA) without the critical damage strain and stress, which may reduce the capacity for bone remodeling,leading to bone degeneration. This study may be useful to design parameter improvement of the revision total knee arthoplasty in biomechanical stability point of view beyond structural stability of revision total knee arthoplasty itself.
참고문헌 (34)
- E. Rubin, "Pathology", pp.1273~2347, Bone and Joints
- A.J. Bailey, "The role of bone in osteoarthritis", Age Ageing, 30(5), pp.374~378 (2001)
- A.J. Carr, "Knee replacement", Lancet, 379(9823), pp.1331~1340 (2012)
- G.A. Engh, "Bone loss with revision total knee arthroplasty : defect classification and alternatives for reconstruction", Instr Course Lect, 48, pp.167~175 (1999)
- H.D. Clarke, "Component fracture in total knee arthroplasty", Knee, 6(4), pp.261~267 (1999)
- Matthew, S. A., "Knee failure mechanisms after total knee arthroplasty", Techniques in Knee Surgery, 3(1), pp.55~59 (2004)
- C.J. Lavernia, "Revision and primary hip and knee arthroplasty. A cost analysis", Clin Orthop Relat Res, (311), pp.136~141 (1995)
- K.P. Emmerson, "Survivorship analysis of the Kinematic Stabilizer total knee replacement : a 10-to 14-year follow-up", J Bone Joint Surg Br, 78(3), pp.441~445 (1996)
- C.S. Ranawat, "The press-fit condylar modular total knee system. Four-to-sixyear results with a posterior-cruciate-substituting design", J Bone Joint Surg Am, 79(3), pp.342~348 (1997)
- D.J. Weir, "Kinematic condylar total knee arthroplasty. 14-year survivorship analysis of 208 consecutive cases", J Bone Joint Surg Br, 78(6), pp.907~911 (1996)
- P. Ducheyne, "Failure of total knee arthroplasty due to loosening and deformation of the tibial component", J Bone Joint Surg Am, 60(3), pp.384~391 (1978)
- J.N. Insall, "The total condylar knee prosthesis in gonarthrosis. A five to nine-year followup of the first one hundred consecutive replacements", J Bone Joint Surg Am, 65(5), pp.619~628 (1983)
- T. Tsonga, "Evaluation of improvement in quality of life and physical activity after total knee arthroplasty in greek elderly women", Open Orthop J, 5, pp.343~347 (2011)
- J. Bugala-Szpak, "Early evaluation of quality of life and clinical parameters after total knee arthroplasty", Ortop Traumatol Rehabil, 12(1), pp.41~49 (2010)
- M.I. Gusso, "The spacer block technique in revision of total knee arthroplasty with septic loosening", Chir Organi Mov, 80(1), pp.21~27 (1995)
- J.W. Barrington, "Contemporary cruciate-retaining total knee arthroplasty with a pegged tibial baseplate. Results at a minimum of ten years", J Bone Joint Surg Am, 91(4), pp.874~878 (2009)
- D.C. Markel, "Analysis of lower extremity embolic material after total knee arthroplasty in a canine model", J Arthroplasty, 14(2), pp.227~232 (1999)
- T.K. Fehring, "Stem fixation in revision total knee arthroplasty : a comparative analysis", Clin Orthop Relat Res, 217(416), pp.217~224 (2003)
- R.L. Barrack, "Pain at the end of the stem after revision total knee arthroplasty", Clin Orthop Relat Res, (367), pp.216~225 (1999)
- D. Taylor, "Bone maintenance and remodeling : a control system based on fatigue damage", J Orthop Res, 15(4), pp.601~606 (1997)
- M. Tew, "Tibiofemoral alignment and the results of knee replacement", J Bone Joint Surg Br, 67(4), pp.551~556 (1985)
- E. Kellis, "Tibiofemoral joint forces during maximal isokinetic eccentric and concentric efforts of the knee flexors", Clin Biomech(Bristol, Avon), 16(3), pp.229~236 (2001)
- I. J. Harrington, "A bioengineering analysis of force actions at the knee in normal and pathological gait", Biomed Eng, 11(5), pp.167~172 (1976)
- A. Completo, "Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA : an in vitro and finite element analysis", Clin Biomech(Bristol, Avon), 25(2), pp.159~165 (2010)
- P.J. Fonseca, "A new concept in underwater high fidelity low frequency sound generation", Rev Sci Instrum, 83(5), pp.055007~ (2012)
- R.L. Austman, "The effect of the density-modulus relationship selected to apply material properties in a finite element model of long bone", J Bio mech, 41(15), pp.3171~3176 (2008)
- G.H. Van Lenthe, "Stress shielding after total knee replacement may cause bone resorption in the distal femur", J Bone Joint Surg Br, 79(1), pp.117~122 (1997)
- A.G. Au, "Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements", J Biomech, 40(6), pp.1410~1416 (2007)
- C.A. Pattin, "Cyclic mechanical property degradation during fatigue loading of cortical bone", J Biomech, 29(1), pp.69~79 (1996)
- M. Taylor, "Finite element analysis of the implanted proximal tibia : a relationship between the initial cancellous bone stresses and implant migration", J Biomech, 31(4), pp.303~310 (1998)
- U. Simon, "Influence of the stiffness of bone defect implants on the mechanical conditions at the interface : a finite element analysis with contact", J Biomech, 36(8), pp.1079~1086 (2003)
- A.G. Au, "A parametric analysis of fixation post shape in tibial knee prostheses", Med Eng Phys, 27(2), pp.123~134 (2005)
- A.G. Au, "Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements", J Biomech, 40(6), pp.1410~1416 (2007)
- N.A. Ramaniraka, "The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface", J Bone Joint Surg Br, 82(2), pp.297~303 (2000)
