골시멘트 특성 및 스템 형상에 따른 시멘트 타입 인공관절의 생체역학적 평가

Biomechanical evaluation of cement type hip implants as conditions of bone cement and variations of stem design

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors.The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters.The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FEA using commercial stem model (Zimmer’s VerSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.

Abstract

The total hip replacement (THR) has been used as the most effective way to restore the function of damaged hip joint. However, various factors have caused some side effects after the THR. Unfortunately, the success of the THR have been decided only by the proficiency of surgeons so far. Hence, It is necessary to find the way to minimize the side effect caused by those factors.The purpose of this study was to suggest the definite data, which can be used to design and choose the optimal hip implant. Using finite element analysis (FEA), the biomechanical condition of bone cement was evaluated. Stress patterns were analyzed in three conditions: cement mantle, procimal femur and stem-cement contact surface. Additionally, micro-motion was analyzed in the stem-cement contact surface. The 3-D femur model was reconstructed from 2-D computerized tomography (CT) images. Raw CT images were preprocessed by image processing technique (i.e. edge detection). In this study, automated edge detection system was created by MATLAB coding for effective and rapid image processing. The 3-D femur model was reconstructed based on anatomical parameters. The stem shape was designed using that parameters.The analysis of the finite element models was performed with the variation of parameters. The biomechanical influence of each parameter was analyzed and derived optimal parameters. Moreover, the results of FEA using commercial stem model (Zimmer’s VerSys) were similar to the results of stem model that was used in this study. Through the study, the improved designs and optimal factors for clinical application were suggested. We expect that the results can suggest solutions to minimize various side effects.

참고문헌 (16)

  1. M.J. Fagan, "Material selection in the design of the femoral component of cemented total hip replacements", Clinical Materials, 1(3), pp.151~167 (1986)
  2. A. Sargeant, "Hip implants:Paper V.Physiological effects", Materials & Design, 27(4), pp.287~307 (2006)
  3. E. Pyburn, "Effect of geometric parameters in the design of hip implants paper IV", Materials & Design, 25(8), pp.715~722 (2004)
  4. Harrigan TP, "A finite element study of the initiation of failure of fixation in cemented femoral total hip components", J Orthop Res, 10(1), pp.134~144 (1992)
  5. Harrigan TE Harris WH, "A three-dimensional nonlinear finite element study of the effect of cementprosthesis debonding in cemented femoral total hip components", Journal of Biomec- hanics, 24(11), pp.1047~1058 (1991)
  6. Amos Race, "Early cement damage around a femoral stem is concentrated at the cement", bone interface, 2003, pp.36(4), 489~496
  7. Herberts P, "How outcome studies have changed total hip arthroplasty practices in Sweden", Clin Orthop Relat Res, 344, pp.44~60 (1997)
  8. Herberts P, "Long-term registration has improved the quality of hip replacement:a review of the Swedish THR Register comparing 160,000 cases", Acta Orthop Scand, 71(2), pp.111~121 (2000)
  9. "A new method to analyse the mechanical behavior of skeletal parts", Acta Orthop Scand, 43, pp.301~307 (1972)
  10. Jonathan R.T. Jeffers, "Cement mantle fatigue failure in total hip replacement:Experimental and computational testing", Journal of Biomechanics, 40(7), pp.1525~1533 (2007)
  11. Jin Ho Che, "Radiographic analysis of the size and shape of proximal", 석사, pp.2004
  12. J. Stolk, "Finite element and experimental models of cemented hip joint reconstructions can produce similar bone and cement strains in pre-clinical tests", Journal of Biomechanics, 35(4), pp.499~510 (2002)
  13. N. Nuno, "Static coefficient of friction between stainless steel and PMMA used in cemented hip and knee implants", Clinical Biomechanics, 21(9), pp.956~962 (2006)
  14. N. Nuno, "Residual stress at the stem-cement interface of an idealized cemented hip stem", Journal of Biomechanics, 35(6), pp.849~852 (2002)
  15. George L. Lucas, "A primer of biomechanics" (1998), Springer
  16. D. Taylor, "Cavatorta,The effect of stress concentrations on the fracture strength of polymethyl-methacrylate", Materials Science and Engineering A, 382(1-2), pp.288~294 (2004)

관련 논문AI추천