Improved Imaging of the Cervico-Thoracic Junction in Computed Tomography

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists’ ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

Abstract

Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists’ ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

참고문헌 (21)

  1. Rothenberg LN, "CT dose assessment" (1994), American Association of Physicists in Medicine Specifications and acceptance testing in quality control of diagnostic x-ray equipment
  2. Hounsfield GN, "Computerized transverse axial scanning (tomography). I. Description of system", Br J Radiol, 46, pp.1016~1022 (1973)
  3. Fullerton GD, "Medical physics of CT and Ultrasound: Tissue imaging and Characterization, Medical physics monograph No. 6", American Institute of physics, pp.717~ (1980)
  4. Siewerdsen JH, "Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter", Med Phys, 28, pp.220~231 (2001)
  5. Jarry G, "Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations", Med Phys, 33, pp.4320~4329 (2006)
  6. Glover GH, "Compton scatters effects in CT reconstruction", Med Phys, 9, pp.860~867 (1982)
  7. Brooks RA, "Beam hardening in x-ray reconstructive tomography", Phys Med Biol, 21, pp.390~398 (1976)
  8. McDavid WD, "Correction for spectral artifacts in cross-sectional reconstruction from x-rays", Med Phys, 4, pp.54~57 (1977)
  9. Link TM, "CT of metal implants: reduction of artifacts using an extended CT scale technique", J Comput Assist Tomogr, 24, pp.165~172 (2000)
  10. Hinderling T, "Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints", J Comput Assist Tomogr, 3, pp.52~57 (1979)
  11. Kalender WA, "Reduction of CT artifacts caused by metallic implants", Radiology, 164, pp.576~577 (1987)
  12. Nassi M, "Iterative reconstruction-reprojection: an algorithm for limited data cardiac-computed tomography", IEEE Trans Biomed Eng, 29, pp.333~341 (1982)
  13. Wang G, "Local computed tomography via iterative deblurring", Scanning, 18, pp.582~588 (1996)
  14. Mott DJ, "The removal of a “cupping” artefact from brain images produced by the EMI 7070 CT scanner", Br J Radiol, 58, pp.873~880 (1985)
  15. Soltanian-Zadeh H, "CT artifact correction: An image processing approach", SPIE, 2710, pp.477~485 (1996)
  16. Kane AG, "Swimmer’s CT: improved imaging of the lower neck and thoracic inlet", Am J Neuroradiol, 25, pp.859~862 (2004)
  17. Gisbert VL, "Incidence and diagnosis of C7-T1 fractures and subluxations in multiple-trauma patients: evaluation of the advanced trauma life support guidelines", Surgery, 106, pp.702~709 (1989)
  18. American College of Surgeons Committee on Trauma, "Advanced trauma life support program for physicians" (1984), American College of Surgeons
  19. Tehranzadeh J, "Efficacy of limited CT for nonvisualized lower cervical spine in patients with blunt trauma", Skeletal Radiol, 23, pp.349~352 (1994)
  20. Wegener OH, "Whole Body Computed Tomography, 2nd ed" (1993), Blackwell Scientific Publications
  21. Lin JT, "Evaluation of occult cervical spine fractures on radiographs and CT", Emerg Radiol, 10, pp.128~134 (2003)

관련 논문AI추천

어깨관절 컴퓨터 단층 검사 시 발생하는 노이즈 및 줄무늬 인공물 감소에 대한 융합 연구장현철, 조평곤중소기업융합학회 · 융합정보논문지2021 · 제11권 제7호The Value of Additional Cervicothoracic Spine Sagittal T2-weighted Images Included in Routine Lumbar Spine MR Imaging강흥식, 박소영, 서지운, 이근영, 이준우대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2013 · 제17권 제2호Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations김유현, 김장섭, 김형철, 신귀순, 신동철, 이기열, 이성현, 이준협, 조평곤, 최종학대한방사선과학회 · Journal of Radiological Science and Technology2009 · 제32권 제4호CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함)장위잉, 정강교, 조유진, 조평곤, 정오하양대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제4호흉부 전산화단층촬영검사를 위한 최적의 저선량 프로토콜에 관한 팬텀연구양숙, 김영근, 김은혜, 왕태욱대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제2호Image Evaluation and Exposure Dose with the Application of Tube Voltage and Adaptive Statistical Iterative Reconstruction of Low Dose Computed Tomography김기정, 문태준, 이혜남대한방사선과학회 · Journal of Radiological Science and Technology2017 · 제40권 제2호

이 간행물의 다른 논문 (12건)