Targeted radionuclides treatment (TRT) requires the establishment of treatment plans that consider various factors, such as the type of radionuclides, target organs, and administration methods. For this reason, in this study, the absorption dose of a single cell was analyzed according to the type of radioisotope used to treat target radionuclides. In this study, a simulation was performed on beta rays used in the treatment of target radionuclides at the cell level using MCNPX (ver. 2.5.0). First, according to the calculation formula, the beam path according to the type of radioisotope for treatment was calculated. Second, the amount of self-radiation by beta rays emitted from cell diameters of 5 μm and 10 μm cell nuclei was evaluated. As a result, it showed a high range proportional to the maximum energy of the beta-ray, and the highest self-dose distribution from 177 Lu radiation sources among therapeutic radioisotopes. This was analyzed as a result that is inversely proportional to the maximum energy of the beta-ray, and it suggests that the selection of a nuclide considering the range of the beta-ray is necessary in the treatment of target radionuclides in the future.
Abstract
Targeted radionuclides treatment (TRT) requires the establishment of treatment plans that consider various factors, such as the type of radionuclides, target organs, and administration methods. For this reason, in this study, the absorption dose of a single cell was analyzed according to the type of radioisotope used to treat target radionuclides. In this study, a simulation was performed on beta rays used in the treatment of target radionuclides at the cell level using MCNPX (ver. 2.5.0). First, according to the calculation formula, the beam path according to the type of radioisotope for treatment was calculated. Second, the amount of self-radiation by beta rays emitted from cell diameters of 5 μm and 10 μm cell nuclei was evaluated. As a result, it showed a high range proportional to the maximum energy of the beta-ray, and the highest self-dose distribution from 177 Lu radiation sources among therapeutic radioisotopes. This was analyzed as a result that is inversely proportional to the maximum energy of the beta-ray, and it suggests that the selection of a nuclide considering the range of the beta-ray is necessary in the treatment of target radionuclides in the future.
참고문헌 (17)
- Kouhkan E, "The Effect of Nucleus Size on the Cell Dose in Targeted Radionuclide Therapy-A Monte Carlo Study", J Med Signals Sens, 10(2), pp.113~118 (2020)
- Tajik-Mansoury MA, "Cellular s-value of beta emitter radionuclide's determined using Geant4 Monte Carlo toolbox, comparison to MIRD s-values", Iran J Nucl Med, 24, pp.37~45 (2016)
- Webster M, "Sizing up the nucleus : Nuclear shape, size and nuclear-envelope assembly", J Cell Sci, 122, pp.1477~1486 (2009)
- Goddu SM, "Cellular dosimetry : Absorbed fractions for monoenergetic electron and alpha particle sources and S‑values for radionuclides uniformly distributed in different cell compartments", J Nucl Med, 35(2), pp.303~316 (1994)
- Kwon NH, "Risk Analysis and Evaluation of Intensity Control Radiation Therapy Using FMEA Techniques", pp.2020
- Ávila A, "Radiation doses from 161Tb and 177Lu in single tumour cells and micrometastases", EJNMMI Physics, pp.1~9 (2020)
- Yonekura Y, "ICRP Publication 140 Radiological Protection in Therapy with Radiopharmaceuticals", ~ (2019)
- Jung JM, "Understanding Radioactive Drugs", Hospital Pharmacy Journal, 33(3), pp.211~217 (2016)
- Lee BE, "Radioactive Drug Management", Hospital Pharmaceutical Society Journal, 33(3), pp.268~277 (2016)
- 김경민, "방사선 내부흡수선량의 의학적 적용", Nuclear Medicine and Molecular Imaging, 42(2), pp.164~171 (2008), 대한핵의학회
- Loveinger R, "MRID primer for absobed dose calculations revised edrrion" (1988), Ebook Library
- octreotate radionuclide therapy: The impact of modeling assumptions on the correlation with in vitro cytotoxicity, "EJNMMI Physics", 2020, 1~19
- 김경민, "방사성핵종을 이용한 치료에서 흡수선량의 평가", Nuclear Medicine and Molecular Imaging, 40(2), pp.120~126 (2006), 대한핵의학회
- 김정훈, "혈관조영 및 중재적 시술 분야 내 종사자의 눈에 대한 선량평가", 한국방사선학회논문지, 12(2), pp.209~216 (2018), 한국방사선학회[DOI]
- Radiation Isotopes Association, "Radiation Theory and Practice" (2014), Ebook Library
- Zukotynski K, "Targeted Radionuclide Therapy : Practical Applications and Future Prospects", Biomark Cancer, 8(Suppl 2), pp.35~38 (2016)
- 김정훈, "몬테카를로 방법을 이용한 이동형 X선 투시검사 시 수술실 내 공간선량평가", 방사선기술과학, 44(3), pp.205~210 (2021), 대한방사선과학회