Dynamic Cardiac Magnetic Resonance Fingerprinting During Vasoactive Breathing Maneuvers: First Results
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
BACKGROUND: Cardiac magnetic resonance fingerprinting (cMRF) enables simultaneous mapping of myocardial T1 and T2 with very short acquisition times. Breathing maneuvers have been utilized as a vasoactive stress test to dynamically characterize myocardial tissue in vivo. We tested the feasibility of sequential, rapid cMRF acquisitions during breathing maneuvers to quantify myocardial T1 and T2 changes. METHODS: We measured T1 and T2 values using conventional T1 and T2-mapping techniques (modified look locker inversion [MOLLI] and T2-prepared balanced-steady state free precession), and a 15 heartbeat (15-hb) and rapid 5-hb cMRF sequence in a phantom and in 9 healthy volunteers. The cMRF5-hb sequence was also used to dynamically assess T1 and T2 changes over the course of a vasoactive combined breathing maneuver. RESULTS: In healthy volunteers, the mean myocardial T1 of the different mapping methodologies were: MOLLI 1,224 ± 81 ms, cMRF15-hb 1,359 ± 97 ms, and cMRF5-hb 1,357 ± 76 ms. The mean myocardial T2 measured with the conventional mapping technique was 41.7 ± 6.7 ms, while for cMRF15-hb 29.6 ± 5.8 ms and cMRF5-hb 30.5 ± 5.8 ms. T2 was reduced with vasoconstriction (post-hyperventilation compared to a baseline resting state) (30.15 ± 1.53 ms vs. 27.99 ± 2.07 ms, p = 0.02), while T1 did not change with hyperventilation. During the vasodilatory breath-hold, no significant change of myocardial T1 and T2 was observed. CONCLUSIONS: cMRF5-hb enables simultaneous mapping of myocardial T1 and T2, and may be used to track dynamic changes of myocardial T1 and T2 during vasoactive combined breathing maneuvers.
Abstract
BACKGROUND: Cardiac magnetic resonance fingerprinting (cMRF) enables simultaneous mapping of myocardial T1 and T2 with very short acquisition times. Breathing maneuvers have been utilized as a vasoactive stress test to dynamically characterize myocardial tissue in vivo. We tested the feasibility of sequential, rapid cMRF acquisitions during breathing maneuvers to quantify myocardial T1 and T2 changes. METHODS: We measured T1 and T2 values using conventional T1 and T2-mapping techniques (modified look locker inversion [MOLLI] and T2-prepared balanced-steady state free precession), and a 15 heartbeat (15-hb) and rapid 5-hb cMRF sequence in a phantom and in 9 healthy volunteers. The cMRF5-hb sequence was also used to dynamically assess T1 and T2 changes over the course of a vasoactive combined breathing maneuver. RESULTS: In healthy volunteers, the mean myocardial T1 of the different mapping methodologies were: MOLLI 1,224 ± 81 ms, cMRF15-hb 1,359 ± 97 ms, and cMRF5-hb 1,357 ± 76 ms. The mean myocardial T2 measured with the conventional mapping technique was 41.7 ± 6.7 ms, while for cMRF15-hb 29.6 ± 5.8 ms and cMRF5-hb 30.5 ± 5.8 ms. T2 was reduced with vasoconstriction (post-hyperventilation compared to a baseline resting state) (30.15 ± 1.53 ms vs. 27.99 ± 2.07 ms, p = 0.02), while T1 did not change with hyperventilation. During the vasodilatory breath-hold, no significant change of myocardial T1 and T2 was observed. CONCLUSIONS: cMRF5-hb enables simultaneous mapping of myocardial T1 and T2, and may be used to track dynamic changes of myocardial T1 and T2 during vasoactive combined breathing maneuvers.
참고문헌 (30)
- Messroghli DR, "Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2*and extracellular volume : a consensus statement by the Society for Cardiovascular Magnetic Resonance(SCMR)endorsed by the European Association for Cardiovascular Imaging(EACVI)", J Cardiovasc Magn Reson, 19, pp.75~ (2017)
- Ma D, "Magnetic resonance fingerprinting", Nature, 495, pp.187~192 (2013)
- Cruz G, "Cardiac magnetic resonance fingerprinting : technical developments and initial clinical validation", Curr Cardiol Rep, 21, pp.91~ (2019)
- Liu Y, "Cardiac magnetic resonance fingerprinting : technical overview and initial results", JACC Cardiovasc Imaging, 11, pp.1837~1853 (2018)
- Yimcharoen S, "Clinical assessment of adenosine stress and rest cardiac magnetic resonance T1 mapping for detecting ischemic and infarcted myocardium", Sci Rep, 10, pp.14727~ (2020)
- Bohnen S, "Stress T1-mapping cardiovascular magnetic resonance imaging and inducible myocardial ischemia", Clin Res Cardiol, 108, pp.909~920 (2019)
- Cavallo AU, "CMR fingerprinting for myocardial T1, T2, and ECV quantification in patients with nonischemic cardiomyopathy", JACC Cardiovasc Imaging, 12, pp.1584~1585 (2019)
- Burrage MK, "Cardiac stress T1-mapping response and extracellular volume stability of MOLLI-based T1-mapping methods", Sci Rep, 11, pp.13568~ (2021)
- Thomas DM, "Effects of adenosine and regadenoson on hemodynamics measured using cardiovascular magnetic resonance imaging", J Cardiovasc Magn Reson, 19, pp.96~ (2017)
- Weyers JJ, "Myocardial blood flow is the dominant factor influencing cardiac magnetic resonance adenosine stress T2", NMR Biomed, 35, pp.e4643~ (2022)
- Yang HJ, "Assessment of myocardial reactivity to controlled hypercapnia with free-breathing T2-prepared cardiac blood oxygen level-dependent MR imaging", Radiology, 272, pp.397~406 (2014)
- Kassner A, "Bloodoxygen level dependent MRI measures of cerebrovascular reactivity using a controlled respiratory challenge : reproducibility and gender differences", J Magn Reson Imaging, 31, pp.298~304 (2010)
- Fischer K, "Response of myocardial oxygenation to breathing manoeuvres and adenosine infusion", Eur Heart J Cardiovasc Imaging, 16, pp.395~401 (2015)
- Hillier E, "The potential of oxygenation-sensitive CMR in heart failure", Curr Heart Fail Rep, 18, pp.304~314 (2021)
- Ochs MM, "Hyperventilation", breath-hold maneuver to detect myocardial ischemia by strain-encoded CMR : diagnostic accuracy of a needle-free stress protocol, 2021, pp.14, 1932~1944
- Fischer K, "Insights into myocardial oxygenation and cardiovascular magnetic resonance tissue biomarkers in heart failure with preserved ejection fraction", Circ Heart Fail, 15, pp.e008903~ (2022)
- Spicher B, "Combined analysis of myocardial deformation and oxygenation detects inducible ischemia unmasked by breathing maneuvers in chronic coronary syndrome", Front Cardiovasc Med, 9, pp.800720~ (2022)
- Hamilton JI, "MR fingerprinting for rapid quantification of myocardial T1, T2, and proton spin density", Magn Reson Med, 77, pp.1446~1458 (2017)
- Winkelmann S, "An optimal radial profile order based on the Golden Ratio for timeresolved MRI", IEEE Trans Med Imaging, 26, pp.68~76 (2007)
- Hamilton JI, "Investigating and reducing the effects of confounding factors for robust T1 and T2 mapping with cardiac MR fingerprinting", Magn Reson Imaging, 53, pp.40~51 (2018)
- Hamilton JI, "Simultaneous multislice cardiac magnetic resonance fingerprinting using low rank reconstruction", NMR Biomed, 32, pp.e4041~ (2019)
- Jiang Y, "Repeatability of magnetic resonance fingerprinting T1 and T2 estimates assessed using the ISMRM", NIST MRI system phantom, 2017, pp.78, 1452~1457
- Hillier E, "Oxygenation-sensitive cardiac MRI with vasoactive breathing maneuvers for the non-invasive assessment of coronary microvascular dysfunction", J Vis Exp, pp.e64149~ (2022)
- Hamilton JI, "Simultaneous mapping of T1and T2 using cardiac magnetic resonance fingerprinting in a cohort of healthy subjects at 1. 5T", J Magn Reson Imaging, 52, pp.1044~1052 (2020)
- Eitel I, "T2-weighted cardiovascular magnetic resonance in acute cardiac disease", J Cardiovasc Magn Reson, 13, pp.13~ (2011)
- van den Boomen M, "Blood oxygen leveldependent MRI of the myocardium with multiecho gradient-echo spin-echo imaging", Radiology, 294, pp.538~545 (2020)
- Liu A, "Adenosine stress and rest T1mapping can differentiate between ischemic, infarcted, remote, and normal myocardium without the need for gadolinium contrast agents", JACC Cardiovasc Imaging, 9, pp.27~36 (2016)
- Piechnik SK, "State-of-the-art review : stress T1 mapping-technical considerations, pitfalls and emerging clinical applications", MAGMA, 31, pp.131~141 (2018)
- Hamilton JI, "Machine learning for rapid magnetic resonance fingerprinting tissue property quantification", Proc IEEE Inst Electr Electron Eng, 108, pp.69~85 (2020)
- Hamilton JI, "A self-supervised deep learning reconstruction for shortening the breathhold and acquisition window in cardiac magnetic resonance fingerprinting", Front Cardiovasc Med, 9, pp.928546~ (2022)
