본문 바로가기
KERD
논문KCI 등재

다양한 코팅 처리에 의한 PEEK 추간체유합보형재의 생체 활성 표면에 관한 연구

A Study on the bioactive surface modification of PEEK intervertebral fusion cage using various coating techniques

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

In this study, the surface of Polyetheretherketone (PEEK) disks was modified to have a hydrophilic surface by applying a coating of Polyethylene glycol (PEG), Hyaluronic acid(HA), and Poly-Dopamine(PDA). The investigation aimed to examine whether the coated surfaces showed enhanced bioactivity for orthopedic applications compared to the pure PEEK. The microstructure, surface characteristics, and wettability of PEEK coated with PEG, HA, and PDA were analyzed using scanning electron microscopy(SEM), FT-IR spectrophotometer, Roughness Measurement System, Micro-Vickers, and Contact angle measurement. The mechanical properties were analyzed using a tensile testing machine, while the MTT assay for cell activity was analyzed using a microplate reader to measure optical density. According to the SEM and FT-IR results, the composition and crystal structure of PEG, HA and PDA coated surface were verified. Also, roughness, hardness, and contact angle were all improved in the coating group compared to the pure PEEK. We checked the HepG2 cell proliferation by using MTT assay on 7th days. In MTT assay results, HepG2 cell proliferation was increased with time, at 7 days, cell viability on discs coated with PDA was significantly higher than pure PEEK, PEG, HA coated group. PDA coated PEEK exhibited the highest surface roughness, hardness, contact angle, and cell activity. The mechanical properties were not affected by the presence of the coating.

Abstract

In this study, the surface of Polyetheretherketone (PEEK) disks was modified to have a hydrophilic surface by applying a coating of Polyethylene glycol (PEG), Hyaluronic acid(HA), and Poly-Dopamine(PDA). The investigation aimed to examine whether the coated surfaces showed enhanced bioactivity for orthopedic applications compared to the pure PEEK. The microstructure, surface characteristics, and wettability of PEEK coated with PEG, HA, and PDA were analyzed using scanning electron microscopy(SEM), FT-IR spectrophotometer, Roughness Measurement System, Micro-Vickers, and Contact angle measurement. The mechanical properties were analyzed using a tensile testing machine, while the MTT assay for cell activity was analyzed using a microplate reader to measure optical density. According to the SEM and FT-IR results, the composition and crystal structure of PEG, HA and PDA coated surface were verified. Also, roughness, hardness, and contact angle were all improved in the coating group compared to the pure PEEK. We checked the HepG2 cell proliferation by using MTT assay on 7th days. In MTT assay results, HepG2 cell proliferation was increased with time, at 7 days, cell viability on discs coated with PDA was significantly higher than pure PEEK, PEG, HA coated group. PDA coated PEEK exhibited the highest surface roughness, hardness, contact angle, and cell activity. The mechanical properties were not affected by the presence of the coating.

참고문헌 (42)

  1. M. Gerber, "Biomechanical assessment of anterior lumbar interbody fusion with an anterior lumbosacral fixation screw-plate : comparison to stand-alone anterior lumbar interbody fusion and anterior lumbar interbody fusion with pedicle screws in an unstable human cadaver model", Spine, 31, pp.762~768 (2006)
  2. Andrew Warburton, "Biomaterials in Spinal Implants: A Review", Neurospine, 17(1), pp.101~110 (2020), 대한척추신경외과학회[DOI]
  3. F. M. Phillips, "Effect of the total facet arthroplasty system after complete laminectomy-facetectomy on the biomechanics of implanted and adjacent segments", The Spine Journal, 9, pp.96~102 (2009)
  4. M. E. Majd, "Anterior cervical reconstruction using titanium cages with anterior plating", Spine, 24, pp.1604~1610 (1999)
  5. M. Niinomi, "Material characteristics and biocompatibility of low rigidity titanium alloys for biomedical applications", Biomaterials in Orthopedics, 22, pp.41~62 (2004)
  6. D. R. Sumner, "Functional adaptation and ingrowth of bone vary as a function of hip implant", Journal of Biomechanics, 31, pp.909~917 (1998)
  7. Y. T. Zhao, "Microstructure and bond strength of HA(+ZrO2+Y2O3)", Ti6Al4V composite coatings fabricated by RF magnetron sputtering, 2006, pp.200, 5354~5363
  8. K. M. Lee, "A recent research and development tendency of dental titanium implant", Jaeryo Madang, 22, pp.33~40 (2009)
  9. Y. Zheng, "Bone-like apatite coating on functionalized poly(etheretherketone)surface via tailored silanization layers technique", Science and Engineering : C, 55, pp.512~523 (2015)
  10. S. M. Kurtz, "PEEK biomaterials in trauma, orthopedic, and spinal implants", Biomaterials, 28, pp.4845~4869 (2007)
  11. P. R. Monich, "Mechanical and biological behavior of biomedical PEEK matrix composites : a focused review", Materials Letters, 185, pp.593~597 (2016)
  12. X. Wu, "Nano-TiO2", PEEK bioactive composite as a bone substitute material : in vitro and in vivo studies, 2012, pp.7, 1215~1225
  13. F. E. Baştan, "Electrophoretic co-deposition of PEEKhydroxyapatite composite coatings for biomedical applications", Colloids and Surfaces B : Biointerfaces, 169, pp.176~182 (2018)
  14. L. Wang, "Characterization of polyetheretherketone–hydroxyapatite nanocomposite materials", Materials Science and Engineering : A, 528, pp.3689~3696 (2011)
  15. L. Wang, "Mechanical properties and microstructure of polyetheretherketone–hydroxyapatite nanocomposite materials", Materials Letters, 64, pp.2201~2204 (2010)
  16. J. H. Lee, "Protein-resistant surfaces prepared by PEOcontaining block copolymer surfactants", Journal of Biomedical Materials Research, 23, pp.351~368 (1989)
  17. Y Mori, "A new antithrombogenic material with long polyethyleneoxide chains", Transactions of the American Society for Artificial Internal Organs, 28, pp.459~463 (1982)
  18. N. P. Desai, "Biological responses to polyethylene oxide modified polyethylene terephthalate surfaces", Journal of Biomedical Materials Research, 25, pp.829~843 (1991)
  19. J. Necas, "Hyaluronic acid(hyaluronan) : a review", Veterinarni Medicina, 53, pp.397~411 (2008)
  20. K. Meyer, "The biological significance of hyaluronic acid and hyaluronidase", Physiological Reviews, 27, pp.335~359 (1947)
  21. B. Sadowitz, "The role of hyaluronic acid in atherosclerosis and intimal hyperplasia", Journal of Surgical Research, 173, pp.63~72 (2012)
  22. T. Sasaki, "Stimulation of osteoinduction in bone wound healing by high-molecular hyaluronic acid", Bone, 16, pp.9~15 (1995)
  23. E. Sato, "High molecular weight hyaluronic acid increases the differentiation potential of the murine chondrocytic ATDC5 cell line", Journal of Orthopaedic Research, 32, pp.1619~1627 (2014)
  24. M. E. Wigg, "The early effect of high molecular weight hyaluronan(hyaluronic acid)on anterior cruciate ligament healing : an experimental study in rabbits", Journal of Orthopaedic Research, 8, pp.425~434 (1990)
  25. D. J. Crisp, "Adhesion and substrate choice in mussels and barnacles", Journal of Colloid and Interface Science, 104, pp.40~50 (1985)
  26. I. You, "Fabrication of a micro-omnifluidic device by omniphilic", omniphobic patterning on nanostructured surfaces, 2014, pp.8, 9016~9024
  27. S. M. Kang, "Onestep modification of superhydrophobic surfaces by a mussel-inspired polymer coating", Angewandte Chemie International Edition, 49, pp.9401~9404 (2010)
  28. M. E. Lynge, "PolyPDAmine", liposome coatings and their interaction with myoblast cells, 2011, pp.3, 2142~2147
  29. S. H. Ku, "General functionalization route for cell adhesion on non-wetting surfaces", Biomaterials, 31, pp.2535~2541 (2010)
  30. R. Luo, "In vitro investigation of enhanced hemocompatibility and endothelial cell proliferation associated with quinonerich polyPDAmine coating", ACS Applied Materials & Interfaces, 5, pp.1704~1714 (2013)
  31. K. Yang, "PolyPDAmine-mediated surface modification of scaffold materials for human neural stem cell engineering", Biomaterials, 33, pp.6952~6964 (2012)
  32. K. Kandasamy, "Polysulfone membranes coated with polymerized 3, 4-dihydroxyl-phenylalanine are a versatile and costeffective synthetic substrate for defined long-term cultures of human pluripotent stem cells", Biomacromolecules, 15, pp.2067~2078 (2014)
  33. J. Ryu, "Musselinspired polyPDAmine coating as a universal route to hydroxyapatite crystallization", Advanced Functional Materials, 20, pp.2132~2139 (2010)
  34. T. An, "Ultra-selective detection of Fe2+ ion by redox mechanism based on fluorescent polymerized PDAmine derivatives", RSC Advances, 7, pp.30582~30587 (2017)
  35. J. Carneiro, "Development and characterization of hyaluronic acid-lysine nanoparticles w i t h p o t e n t i a l a s i n n o v a t i v e dermal filling", Brazilian Journal of Pharmaceutical Sciences, 52, pp.645~651 (2016)
  36. 권기완, "Enhanced Tissue Compatibility of Polyetheretherketone Disks by Dopamine-Mediated Protein Immobilization", Macromolecular Research, 26(2), pp.128~138 (2018), 한국고분자학회[DOI]
  37. M. Sahu, "Fabrication of Cu2ZnSnS4 light absorber using a costeffective mechanochemical method for photovoltaic applications", Materials, 15, pp.1708~ (2022)
  38. L. Sennerby, "Structure of the bone", titanium interface in retrieved clinical oral implants, 1992, pp.2, 103~111
  39. A. Wennerberg, "A 1 year follow-up of implants of different surface roughness placed inrabit bone", International Journal of Oral &Maxillofacial Implants, 12, pp.1~21 (1997)
  40. 김광윤, "폴리카보네이트 임시수복재료의 물성 평가", 구강회복응용과학지, 36(3), pp.168~175 (2020), 대한턱관절교합학회[DOI]
  41. S. J. Lee, "Surface modification of 3D-printed porous scaffolds via musselinspired polydopamine and effective immobilization of rhBMP-2 to promote osteogenic differentiation for bone tissue engineering", Acta Biomaterialia, 40, pp.182~191 (2016)
  42. J. S. Park, "Surface modification of a three-dimensional polycaprolactone scaffold by polydopamine, biomineralization, and BMP-2immobilization for potential bone tissue applications", Colloids and Surfaces B : Biointerfaces, 199, pp.111528~ (2021)

관련 논문AI추천

PVD 공정을 이용한 Titanium-Coated PEEK 표면의 접착 강도 및 내구성 평가안윤호, 유경주, 정용훈한국표면공학회 · 한국표면공학회지2025 · 제58권 제6호마그네트론 스퍼터링 시스템을 이용한 정형외과용 PEEK의 타이타늄/하이드록시아파타이트 이중 코팅층의 표면 특성 분석강관수, 박태현, 양재웅, 우수헌, 정용훈, 정태곤한국표면공학회 · 한국표면공학회지2018 · 제51권 제3호요추부 다공성 추간체유합보형재의 개발 및 기계적 성능 평가김경아, 박광민, 안경기, 안윤호, 유경주, 차은종대한의용생체공학회 · 의공학회지2020 · 제41권 제1호형상학적 변수에 따른 다공성 구조의 가변탄성계수를 기반으로 한 추간체유합보형재의 임상적 안전성 평가김성진, 김정성, 이용경, 최재혁, 홍영기대한의용생체공학회 · 의공학회지2019 · 제40권 제5호TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석강관수, 박태현, 양재웅, 우수헌, 정용훈, 정태곤한국표면공학회 · 한국표면공학회지2019 · 제52권 제3호Effects of the immobilization of heparin and rhPDGF-BB to titanium surfaces for the enhancement of osteoblastic functions and anti-inflammation김성은, 신상완, 심준성, 심지석, 윤미정, 이경래, 이정열, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제3호

이 간행물의 다른 논문 (8건)