고체비적검출기를 이용한 500 MeV/u 철 이온의 선에너지전이 교정
LET Calibration of Fe 500 MeV/u Ions using SSNTD
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ( ) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.
Abstract
In this study, LET (Linear Energy Transfer) calibration of CR-39 SSNTD (Solid State Nuclear Track Detector) was performed using 500 MeV/u Fe heavy ions in HIMAC (Heavy Ion Medical Accelerator) for high LET radiation dosimetry. The irradiated CR-39 SSNDT were etched according JAXA (Japan Aerospace Exploration Agency) etching conditions. And the etched SSNTD were analyzed by using Image J. Determined dose-mean lineal energy ( ) of 500 MeV/u Fe is about 283.3 keV/um by using the CR-39 SSNTD. This value is very similar result compare to the results calculated by GEANT4 Monte Carlo simulation and measured with TEPC active radiation detector. We confirmed that the CR-39 SSNTD was useful for high LET radiation dosimetry such as heavy iron ions.
참고문헌 (14)
- "Ann. ICRP 37 (2-4)" (2007)[URL]
- Ngoc-Tu Lanh, "High Performance of SWIR HgCdTe Photovoltaic Detector Passivated by ZnS", 센서학회지, 13(2), pp.128~132 (2004), 한국센서학회
- J. A. Caffrey, "A review of instruments and methods for dosimetry in space", Adv. in Space Res, 47, pp.563~574 (2011)
- D. Zhoua, "LET calibration for CR-39 detectors in different oxygen environments", Rad. Meas, 42, pp.1499~1506 (2007)
- J. L. Kim, "Energy and Angular Response of CR-39 Neutron Track Detector", J. Korean Nucl. Soc, 20(2), pp.71~79 (1988)
- V. Kumar, "Optimazation of CR-39 as a Neutron Detector", Indian J. Pure & Appl. Phys, 48, pp.466~469 (2010)
- J. M. C. Brown, "Development of an energy discriminate CR-39® nuclear track etch dosimeter for Radon-220 gas measurements", J. Environ. Rad., 102(10), pp.901~905 (2011)
- N. F. Santos, "CR-39 alpha particle spectrometry for the separation of the radon decay product 214Po from the thoron decay product 212Po", Rad. Meas., 45(7), pp.823~826 (2010)
- A. Nagamatsu, "Area radiation monitoring on ISS Increments 17 to 22 using PADLES in the Japanese Experiment Module Kibo", Rad. Meas, 59, pp.84~93 (2013)
- 남욱원, "마이크로 도시메트리용 다분할 조직등가비례계수기의 개발과 특성 평가", 센서학회지, 24(2), pp.101~106 (2015), 한국센서학회[DOI]
- D. Zhou, "The experimental and simulated LET spectrum and charge spectrum from CR-39 detectors exposed to irons near CRaTER at BNL", Rad. Meas, 45, pp.916~922 (2010)
- David R. Farrar, "Microdosimetric measurements of shielding effects for iron particles at 500 MeV", nucleon incident upon aluminum and polyethylene, Colorado State University, 2007
