Cone-beam Computed Tomography Measurement of the Position of the Inferior Alveolar Nerve Canal in Mandibular Prognathism
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background and Objectives: To determine the anatomic position of the inferior alveolar nerve (IAN) canal in patients with mandibular prognathism using the cone-beam CT (CBCT). Materials and Methods: Fifty rami from 25 patients were evaluated. The images were taken by i-CAT and reconstructed 3-dimensionally using the Simplant 11 program. The linear distances between the IAN canal to the buccal cortex (a, a* and a*), from the IAN canal to the alveolar crest (b and b*) and the anterior margin (b*) and finally the buccal cortical thickness (c, c* and c*) were measured at three reference planes (VP, OP and HP). Results: On the left side, the average distance of a, b and c were 7.12, 15.96 and 3.60 mm on the VP plane, respectively. On the OP, the distance of a*, b* and c* was 6.11, 8.83 and 2.63 mm. For the HP, the distance of a*, b* and c* was 4.84, 10.11 and 2.30 mm. On the right side, the distance of a, b and c, on the VP, was 7.10, 16.13 and 3.42 mm, respectively. On the OP, the distance of a*, b* and c* was 4.77, 8.75 and 2.68 mm. On the HP, the distance of a*, b* and c* was 4.55, 9.84 and 2.38 mm. Regarding the difference between genders, the distance in male’s was longer than female’s on the VP (p=0.019), and was thicker in males than females on the HP (p=0.002). Conclusion: The CBCT data provided accurate information about the location and course of the IAN.
Abstract
Background and Objectives: To determine the anatomic position of the inferior alveolar nerve (IAN) canal in patients with mandibular prognathism using the cone-beam CT (CBCT). Materials and Methods: Fifty rami from 25 patients were evaluated. The images were taken by i-CAT and reconstructed 3-dimensionally using the Simplant 11 program. The linear distances between the IAN canal to the buccal cortex (a, a* and a*), from the IAN canal to the alveolar crest (b and b*) and the anterior margin (b*) and finally the buccal cortical thickness (c, c* and c*) were measured at three reference planes (VP, OP and HP). Results: On the left side, the average distance of a, b and c were 7.12, 15.96 and 3.60 mm on the VP plane, respectively. On the OP, the distance of a*, b* and c* was 6.11, 8.83 and 2.63 mm. For the HP, the distance of a*, b* and c* was 4.84, 10.11 and 2.30 mm. On the right side, the distance of a, b and c, on the VP, was 7.10, 16.13 and 3.42 mm, respectively. On the OP, the distance of a*, b* and c* was 4.77, 8.75 and 2.68 mm. On the HP, the distance of a*, b* and c* was 4.55, 9.84 and 2.38 mm. Regarding the difference between genders, the distance in male’s was longer than female’s on the VP (p=0.019), and was thicker in males than females on the HP (p=0.002). Conclusion: The CBCT data provided accurate information about the location and course of the IAN.
참고문헌 (24)
- MacIntosh RB, "Experience with the sagittal osteotomy of the mandibular ramus: A 13-year review", J Maxillofac Surg, 9, pp.151~165 (1981)
- Turvey TA, "Intraoperative complications of sagittal osteotomy of the mandibular ramus: Incidence and management", J Oral Maxillofac Surg, 43, pp.504~509 (1985)
- Acebal-Bianco F, "Perioperative complications in corrective facial orthopedic surgery: 5-year retrospective study", J Oral Maxillofac Surg, 58, pp.754~760 (2000)
- Westermark A, "Inferior alveolar nerve function after sagittal split osteotomy of the mandible: Correlation with degree of intraoperative nerve encounter and other variables in 496 operations", Br J Oral Maxillofac Surg, 36, pp.429~433 (1998)
- Yoshida T, "Impairment of the inferior alveolar nerve after sagittal split osteotomy", J Cranio Maxillofac Surg, 17, pp.271~277 (1989)
- Tamas F, "Position of the mandibular canal", Int J Oral Maxillofac Surg, 16, pp.65~69 (1987)
- Gowgiel JM, "The position and course of the mandibular canal", J Oral Implantol, 18, pp.383~385 (1992)
- Kim HJ, "Mandibular anatomy related to sagittal split ramus osteotomy in Koreans", Yonsei Med J, 38, pp.19~25 (1997)
- Yamamoto R, "Relationship of the mandibular canal to the lateral cortex of the mandibular ramus as a factor in the development of neurosensory disturbance after bilateral sagittal split osteotomy", J Oral Maxillofac Surg, 60, pp.490~495 (2002)
- Tsuji Y, "Computed tomographic analysis of the position and course of the mandibular canal: relevance to the sagittal split ramus osteotomy", Int J Oral Maxillofac Surg, 34, pp.243~246 (2005)
- Arai Y, "Development of a compact computed tomographic apparatus for dental use", Dentomaxillofac Radiol, 28, pp.245~248 (1999)
- Nakajima A, "Two- and three-dimensional orthodontic imaging using limited cone beam-computed tomography", Angle Orthod, 75, pp.895~903 (2005)
- Kobayashi K, "Accuracy in measurement of distance using limited cone-beam computerized tomography", Int J Oral Maxillofac Implants, 19, pp.228~231 (2004)
- Honda K, "Ortho cubic super-high resolution computed tomography; a new radiographic technique with application to the temporomandibular joint", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 91, pp.239~243 (2001)
- Periago DR, "Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program", Angle Orthod, 78, pp.387~395 (2008)
- 한수연, "3차원 CT 영상을 이용한 정상교합자의 안면 연조직 계측 분석", 대한치과교정학회지, 35(6), pp.409~419 (2005), 대한치과교정학회
- Ludlow JB, "Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT", Dentomaxillofac Radiol, 35, pp.219~226 (2006)
- 이의태, "Cone beam형 전산화단층촬영에 의한 흡수선량", 대한구강악안면방사선학회지, 37(2), pp.87~92 (2007), 대한구강악안면방사선학회
- Rajchel J, "The anatomical location of the mandibular canal: Its relationship to the sagittal ramus osteotomy", Int J Adult Orthod Orthognath Surg, 1, pp.37~47 (1986)
- Levine MH, "Inferior alveolar nerve position: a clinical and radiographic study", J Oral Maxillofac Surg, 65, pp.470~474 (2007)
- Ha SsY, "A Computerized Tomographic Study on the Location of the Mandibular Canal and the Cortical Thickness of the Mandible", Kor J Oral Maxillofac Radiol, 27, pp.217~230 (1997)
- Carter TB, "Cortical thickness in human mandibles: clinical relevance to the sagittal split ramus osteotomy", Int J Adult Orthod Orthognath Surg, 6, pp.257~260 (1991)
- Ylikontiola L, "Comparison of three radiographic methods used to locate the mandibular canal in the buccolingual direction before bilateral sagittal split osteotomy", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 93, pp.736~742 (2002)
- Pyo SW, "전산화 단층촬영을 이용한 하악 후구치부 피질골 두께 계측", Kor J Oral Maxillofac Implantol, 10, pp.32~40 (2006)
