본문 바로가기
KERD
논문KCI 등재

Assessment of the anterior loop of the inferior alveolar nerve via cone-beam computed tomography

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The aim of this study was to evaluate different anatomical variants of the anterior loop of the inferior alveolar nerve (IAN) via cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 71 patients (36 males and 35 females) were evaluated. We used the classification described by Solar for IAN evaluation. In this classification, three different types of IAN loops were introduced prior to emerging from the mental foramen. We classified pa-tients according to this system and introduced a new, fourth type.Results: Type I was seen in 15 sites (10.6%), type II in 39 sites (27.5%), and type III in 50 sites (35.2%). We found a new type in 38 sites (26.8%) that constituted a fourth type. Conclusion: We found that type III was the most common variant. In the fourth type, the IAN was not detectable because the main nerve was adjacent to the cortical plate and the incisive branch was thinner than the main branch and alongside it. In this type, more care is needed for surgeries including inferior alveolar and mental nerve transposition.

Abstract

Objectives: The aim of this study was to evaluate different anatomical variants of the anterior loop of the inferior alveolar nerve (IAN) via cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 71 patients (36 males and 35 females) were evaluated. We used the classification described by Solar for IAN evaluation. In this classification, three different types of IAN loops were introduced prior to emerging from the mental foramen. We classified pa-tients according to this system and introduced a new, fourth type.Results: Type I was seen in 15 sites (10.6%), type II in 39 sites (27.5%), and type III in 50 sites (35.2%). We found a new type in 38 sites (26.8%) that constituted a fourth type. Conclusion: We found that type III was the most common variant. In the fourth type, the IAN was not detectable because the main nerve was adjacent to the cortical plate and the incisive branch was thinner than the main branch and alongside it. In this type, more care is needed for surgeries including inferior alveolar and mental nerve transposition.

참고문헌 (35)

  1. Mraiwa N, "Clinical assessment and surgical implications of anatomic challenges in the anterior mandible", Clin Implant Dent Relat Res, 5, pp.219~225 (2003)
  2. Jacobs R, "Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan", Dentomaxillofac Radiol, 31, pp.322~327 (2002)
  3. Agbaje JO, "CBCT-based predictability of attachment of the neurovascular bundle to the proximal segment of the mandible during sagittal split osteotomy", Int J Oral Maxillofac Surg, 42, pp.308~315 (2013)
  4. Alqerban A, "In-vitro comparison of 2 cone-beam computed tomography systems and panoramic imaging for detecting simulated canine impaction-induced external root resorption in maxillary lateral incisors", Am J Orthod Dentofacial Orthop, 136, pp.764.e1~764.e11 (2009)
  5. White SC, "Cone-beam imaging in dentistry", Health Phys, 95, pp.628~637 (2008)
  6. Chávez-Lomeli ME, "The human mandibular canal arises from three separate canals innervating different tooth groups", J Dent Res, 75, pp.1540~1544 (1996)
  7. de Villiers H, "The skull of the South African Negro: a biometrical and morphological study" (1970), Wits University Press
  8. Ngeow WC, "A radiographic study on the visualization of the anterior loop in dentate subjects of different age groups", J Oral Sci, 51, pp.231~237 (2009)
  9. Arzouman MJ, "Observations of the anterior loop of the inferior alveolar canal", Int J Oral Maxillofac Implants, 8, pp.295~300 (1993)
  10. Solar P, "A classification of the intraosseous paths of the mental nerve", Int J Oral Maxillofac Implants, 9, pp.339~344 (1994)
  11. Kajan ZD, "Presence and course of the mandibular incisive canal and presence of the anterior loop in cone beam computed tomography images of an Iranian population", Oral Radiol, 28, pp.55~61 (2012)
  12. Vazquez L, "Efficacy of panoramic radiographs in the preoperative planning of posterior mandibular implants: a prospective clinical study of 1527 consecutively treated patients", Clin Oral Implants Res, 19, pp.81~85 (2008)
  13. Wismeijer D, "Patients'perception of sensory disturbances of the mental nerve before and after implant surgery: a prospective study of 110 patients", Br J Oral Maxillofac Surg, 35, pp.254~259 (1997)
  14. Kalender A, "Evaluation of the mental foramen and accessory mental foramen in Turkish patients using cone-beam computed tomography images reconstructed from a volumetric rendering program", Clin Anat, 25, pp.584~592 (2012)
  15. Kuzmanovic DV, "Anterior loop of the mental nerve: a morphological and radiographic study", Clin Oral Implants Res, 14, pp.464~471 (2003)
  16. Chen JC, "A retrospective comparison of the location and diameter of the inferior alveolar canal at the mental foramen and length of the anterior loop between American and Taiwanese cohorts using CBCT", Surg Radiol Anat, 35, pp.11~18 (2013)
  17. Parnia F, "Characteristics of anatomical landmarks in the mandibular interforaminal region: a cone-beam computed tomography study", Med Oral Patol Oral Cir Bucal, 17, pp.e420~e425 (2012)
  18. Danforth RA, "3-D volume imaging for dentistry: a new dimension", J Calif Dent Assoc, 31, pp.817~823 (2003)
  19. Haghanifar S, "Radiographic evaluation of the mental foramen in a selected Iranian population", Indian J Dent Res, 20, pp.150~152 (2009)
  20. Bushong SC, "Radiologic science for technologists: physics, biology, and protection", pp.29~30 (2004), Elsevier
  21. Katakami K, "Characteristics of accessory mental foramina observed on limited cone-beam computed tomography images", J Endod, 34, pp.1441~1445 (2008)
  22. 고광준, "Cone beam형 전산화단층영상을 이용한 하악관의 전방고리 및 이공에 관한 연구", Imaging Science in Dentistry, 39(2), pp.81~87 (2009), 대한구강악안면방사선학회
  23. Demir A, "Anterior loop of the mental foramen in a Turkish subpopulation with dentate patients: a cone beam computed tomography study", J Marmara Univ Inst Health Sci, 5, pp.231~238 (2015)
  24. Rosenquist B, "Is there an anterior loop of the inferior alveolar nerve?", Int J Periodontics Restorative Dent, 16, pp.40~45 (1996)
  25. Kaya Y, "Retrospective radiographic evaluation of the anterior loop of the mental nerve: comparison between panoramic radiography and spiral computerized tomography", Int J Oral Maxillofac Implants, 23, pp.919~925 (2008)
  26. Benninger B, "Dental implant placement investigation: is the anterior loop of the mental nerve clinically relevant?", J Oral Maxillofac Surg, 69, pp.182~185 (2011)
  27. Mraiwa N, "Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations", Surg Radiol Anat, 25, pp.416~423 (2003)
  28. Bavitz JB, "An anatomical study of mental neurovascular bundle-implant relationships", Int J Oral Maxillofac Implants, 8, pp.563~567 (1993)
  29. Mardinger O, "Anterior loop of the mental canal: an anatomical-radiologic study", Implant Dent, 9, pp.120~125 (2000)
  30. 유선경, "Morphological assessment of the anterior loop of the mandibular canal in Koreans", Anatomy and Cell Biology, 48(1), pp.75~80 (2015), 대한해부학회
  31. Uchida Y, "Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography", J Oral Maxillofac Surg, 67, pp.744~750 (2009)
  32. Oguz O, "Evaluation of location of mandibular and mental foramina in dry, young, adult human male, dentulous mandibles", West Indian Med J, 51, pp.14~16 (2002)
  33. Rosa MB, "Retrospective study of the anterior loop of the inferior alveolar nerve and the incisive canal using cone beam computed tomography", Int J Oral Maxillofac Implants, 28, pp.388~392 (2013)
  34. Apostolakis D, "The dimensions of the mandibular incisive canal and its spatial relationship to various anatomical landmarks of the mandible: a study using cone beam computed tomography", Int J Oral Maxillofac Implants, 28, pp.117~124 (2013)
  35. 이정교, "안전한 임플란트 식립을 위한 하악골 내측면의 CBCT를 이용한 해부학적 연구", 대한구강악안면외과학회지, 37(1), pp.43~48 (2011), 대한구강악안면외과학회

관련 논문AI추천

Cone-beam Computed Tomography Measurement of the Position of the Inferior Alveolar Nerve Canal in Mandibular Prognathism고영경, 박재억, 박지영, 윤성훈, 표성운대한구강악안면외과학회 · 대한구강악안면외과학회지2009 · 제35권 제1호3-dimensional reconstruction of mandibular canal at the interforaminal region using microcomputed tomography in Korean김흥중, 김희중, 유선경, 이철권, 전용현, 정재헌대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제6호Evaluation of the course of the inferior alveolar canal in the mandibular ramus using cone beam computed tomography권경환, Jae-Min Lee, Kyu-Bong Sim대한구강악안면외과학회 · 대한구강악안면외과학회지2012 · 제38권 제4호조직형태학적 분석을 통한 아래이틀신경 내 턱끝가지의 형태학적 배열김흥중, 모신엽, 유선경, 이동설, 이명화, 이철권, 조광희치의학연구원 · Oral Biology Research2013 · 제37권 제2호Measurement of mandibular lingula location using cone-beam computed tomography and internal oblique ridge-guided inferior alveolar nerve blockHo-Yeol Jang, Seung-Jung Han대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제3호Three-dimensional observations of the incisive foramen on cone-beam computed tomography image analysis김연태, 이재홍, 정성념대한치주과학회 · Journal of Periodontal & Implant Science2020 · 제50권 제1호

이 간행물의 다른 논문 (10건)