구강 악안면 영역의 생체 흡수성 고정판 사용에 관한 임상 연구
A CLINICAL STUDY OF BIODEGRADABLE PLATES AND SCREWS IN ORAL AND MAXILLOFACIAL SURGERY
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.
Abstract
Metallic bone plates and screws have been commonly used in oral and maxillofacial surgery for internal fixation. However, there are several disadvantages such as atrophy of cortical bone inherent to excessive rigid fixation systems, growth disturbance in growing individual, allergy reaction, interference with radiographic imaging, palpability, thermal sensitibity and the need for subsequent removal. To overcome these disadvantages and avoid additional surgery of removal of plates and screws, there have been many studies of biodegradable plates and screws. But, It also has complication such as foreign body reactions. We have undertaken a clinical and retrospective study on 140 patients in Dept. of Oral and Maxillofacial Surgery, Inha University Hospital from February 2006 to March 2009. The purpose of this study is to report the clinical cases and review of the literatures with biodegradable plates and screws. And we concluded following results. 1. 6 cases(3.4%) of the 177 operation sites(140 patients) experienced complications. 1 case(0.6%) was a failure of initial fixation, 1 case(0.6%) was a postoperative infection, 4 cases(2.3%) were inflammations or foreign body reaction. 2. Postoperative infections, inflammations and foreign body reactions were completely recovered with incision and drainage, supporative care with antibiotic coverage and removal of biodegradable plates. 3. Biodegradable plates and screws provide acceptable rigidity and stability clinically. But, long-term observation is required for the tissue reactions around the biodegradable plates and screws because of long resorption periods of the biodegradable materials.
참고문헌 (40)
- Jeffrey A, "Early experience with biodegradable fixation for congenital pediatric craniofacial surgery", J Craniofac Surg, 8, pp.110~115 (1997)
- Cutright DE, "The repair of fractures of the orbital floor using biodegradable polylactic acid", Oral Surg, pp.28~34 (1972)
- Cutright DE, "Tissue reaction to the biodegradable polylactic acid suture", Oral Surg, 31, pp.134~139 (1971)
- Cutright DE, "Histological comparision of polylactic and polyglycolic acid suture", Oral Surg, 32, pp.165~173 (1971)
- Dardick H, "A new absorbable synthetic suture in growing and adult primary vascular anastomoses: Morphologic study", Oral Surg, 68, pp.1112~1121 (1970)
- Cutright DE, "Fracture reduction using a biodegradable material, polylactic acid", J Oral Surg, 29, pp.393~397 (1971)
- Alpert B, "Removal of asymptomatic bone plates used for orthognathic surgery and facial fractures", J Oral Maxillofac Surg, 54, pp.618~621 (1996)
- Ellis E, "Treatment of mandibular angle fracture using one noncompression miniplate", J Oral Maxillofac Surg, 54, pp.864~871 (1996)
- Ashammakhi N, "Developments in craniomaxillofacial surgery: use of self-reinforced bioabsorbable osteofixation devices", Plast Reconstr Surg, 108, pp.167~180 (2001)
- Suuronen R, "Biodegradable fracture fixation devices in maxillofacial surgery", Int J Oral Maxillofac Surg, 22, pp.50~57 (1993)
- Rokkanen P, "Biodegradable implants in fracture fixation: early results of treatment of fractures of the ankle", Lancet, 325, pp.1422~1424 (1985)
- Bos RR, "Bioabsorbable plates and screws for internal fixation of mandibular fractures. A study in six dogs", Int J Oral Maxillofac Surg, 18, pp.365~369 (1989)
- Bos RR, "Bone plates and screws of bioabsorbable poly(L-lactide). An animal pilot study", Br J Oral Maxillofac Surg, 27, pp.467~476 (1989)
- Rozema FR, "Poly(L-lactide) implants in repair of defects of the orbital floor. An animal study", J Oral Maxillofac Surg, 48, pp.1305~1309 (1990)
- Yerit KC, "Fixation of mandibular fractures with biodegradable plates and screws", Oral Surg, 94, pp.294~300 (2002)
- Kallela I, "Skeletal stability after mandibular advancement and fixation with biodegradable screws", Int J Oral Maxillofac Surg, 27, pp.3~8 (1998)
- Haers PE, "Biodegradable self reinforced poly-L", DLlactide plates and screw in bimaxillary orthognathic surgery: short-term skeletal stability and material related failures, 1998, pp.26, 363~372
- Champy M, "Mandibular osteosynthesis by miniature screwed plates via a buccal approach", J Maxillofac Surg, 6, pp.14~21 (1978)
- William S, "Bioabsorbable polymer science for the practicing surgeons", J Craniofac surgery, 8, pp.87~91 (1997)
- Barry L, "Nonmetallic fixation in traumatic midfacial fractures", J Craniofac surgery, 8, pp.103~109 (1997)
- Bo ¨stman O, "Foreignbody reactions to fracture fixation implants of biodegradable synthetic polymers", J Bone Joint Surg, 72, pp.592~596 (1990)
- Iizuka T, "Reconstruction of orbital floor with polydioxanone plate", Int J Oral Maxillofac Surg, 20, pp.83~87 (1991)
- Kontio R, "Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant", Int J Oral Maxillofac Surg, 30, pp.278~285 (2001)
- Cantaloube D, "Use of a cup-shaped implant of polydioxanone in orbital-malar fractures", Rev Stomatol Chir Maxillofac, 90, pp.48~51 (1989)
- Roed-Peterson B, "Absorbable synthetic suture material for internal fixation of fracture of the mandible", Int J Oral Maxillofac Surg, 3, pp.133~136 (1974)
- Friden T, "Severe aseptic synovitis of the knee after biodegradable internal fixation: A case report", Acta Orthop Scand, 63, pp.94~97 (1992)
- Bergsma EJ, "Foreign body reactions to resorbable poly(L-lactide) bone plates and screw used for the fixation of unstable zygomatic fractures", J Oral Maxillofax Surg, 51, pp.666~670 (1993)
- Bergsma JE, "Late degradation tissue response to poly(L-lactide) bone plates and screw", Biomaterials, 16, pp.25~31 (1995)
- Takizawa T, "Foreign body gonititis caused by a broken poly-lactic acid screw", J of Arthroscopic and Related Surg, 14, pp.329~330 (1998)
- Matsusue Y, "In vitro and in vivo studies on bioabsorbable ultra high strength poly(L-lactide) rods", J Biomed Mater Res, 26, pp.1553~1567 (1992)
- Edwards RC, "The fate of resorbable poly- L-lactic", polyglycolic acid bone fixation devices in orthognathic surgery, 2001, pp.59, 19~25
- Park HW, "The effects of resorbable plate in the healing process of mandibular fracture of the rabbits", J Korean Assoc Maxillofac Plast Reconstr Surg, 21(2), pp.131~138 (1999)
- Suuronen R, "Bioabsorbable screw, Current state of the art in facial fracture repair", J Craniomaxillofac Trauma, 6(1), pp.19~27 (2000)
- Landes CA, "Resorbable plate osteosynthesis of dislocated or pathological mandibular fractures: A prospective clinical trial of two amorphous L-", DL-lactide copolymer 2-mm miniplate systems, 2003, pp.111, 601~610
- 정종철, "악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구", 대한구강악안면외과학회지, 29(6), pp.438~443 (2003), 대한구강악안면외과학회
- 최진호, "생체 흡수성 고정판을 이용한 하악골 골절치료의 예후", 대한악안면성형재건외과학회지, 27(1), pp.30~38 (2005), 대한악안면성형재건외과학회
- Laughlin RM, "Resorbable plates for the fixation of mandibular fractures: A prospective study", J Oral Maxillofac Surg, 65, pp.89~96 (2007)
- Bell RB, "The use of biodegradable plates and screws to stabilize facial fractures", J Oral Maxillofac Surg, 64, pp.31~39 (2006)
- Tuovinen V, "A retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium", J Oral Maxillofac Surg, 52, pp.931~935 (1994)
- 최은주, "Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구", 대한구강악안면외과학회지, 32(3), pp.222~225 (2006), 대한구강악안면외과학회
