Objectives: The aim of this study was to investigate average working lengths of Korean posterior teeth and evaluate validity of endodontic file length. Materials and Methods: The endodontic working length of the posterior teeth of 670 Korean patients were measured than each mean value and standard deviation were investigated than the frequency deviation and standard deviation per each length were calculated. Results: Among the canals of premolar, 66.5% of canal length was marked under 20 mm by endodontic working length and 95.4% could be measured under 22 mm and Among the canals of molars, 95.5% of canal length was marked under 20 mm endodontic working length . Conclusions: With the result of measurement of endodontic working length of premolars of Korean, it suggested that 23 mm endodontic file is more proper than the 21 mm and 25 mm file on the market. [J Kor Acad Cons Dent 2010;35(6):429-435.]

Abstract

Objectives: The aim of this study was to investigate average working lengths of Korean posterior teeth and evaluate validity of endodontic file length. Materials and Methods: The endodontic working length of the posterior teeth of 670 Korean patients were measured than each mean value and standard deviation were investigated than the frequency deviation and standard deviation per each length were calculated. Results: Among the canals of premolar, 66.5% of canal length was marked under 20 mm by endodontic working length and 95.4% could be measured under 22 mm and Among the canals of molars, 95.5% of canal length was marked under 20 mm endodontic working length . Conclusions: With the result of measurement of endodontic working length of premolars of Korean, it suggested that 23 mm endodontic file is more proper than the 21 mm and 25 mm file on the market. [J Kor Acad Cons Dent 2010;35(6):429-435.]

참고문헌 (27)

  1. Kim S, "Modern endodontic practice: instruments and techniques", Dent Clin North Am., 48(1), pp.1~9 (2004)
  2. Barbakow F, "The LightSpeed system", Dent Clin North Am, 48(1), pp.113~135 (2004)
  3. Clauder T, "ProTaper NT system", Dent Clin North Am, 48(1), pp.87~111 (2004)
  4. Hsu YY, "The ProFile system", Dent Clin North Am, 48(1), pp.69~85 (2004)
  5. Mounce RE, "The K3 rotary nickel-titanium file system", Dent Clin North Am, 48(1), pp.137~157 (2004)
  6. Takatsuka S, "Disc and condyle translation in patients with temporomandibular disorder", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99(5), pp.614~621 (2005)
  7. Nunez SC, "Management of mouth opening in patients with temporomandibular disorders through low-level laser therapy and transcutaneous electrical neural stimulation", Photomed Laser Surg, 24(1), pp.45~49 (2006)
  8. Kuttler Y, "Microscopic investigation of root apexes", J Am Dent Assoc, 50(5), pp.544~552 (1955)
  9. Eliasson S, "Radiographic study of alveolar bone height related to tooth and root length", Community Dent Oral Epidemiol, 14(3), pp.169~171 (1986)
  10. Forsberg J, "Radiographic reproduction of endodontic “working length”comparing the paralleling and the bisecting-angle techniques", Oral Surg Oral Med Oral Pathol, 64(3), pp.353~360 (1987)
  11. Burch JG, "The relationship of the apical foramen to the anatomic apex of the tooth root", Oral Surg Oral Med Oral Pathol, 34(2), pp.262~268 (1972)
  12. Dummer PM, "The position and topography of the apical canal constriction and apical foramen", Int Endod J., 17(4), pp.192~198 (1984)
  13. Kim E, "Electronic apex locator", Dent Clin North Am, 48(1), pp.35~54 (2004)
  14. Vajrabhaya L, "Accuracy of apex locator", Endod Dent Traumatol, 13(4), pp.180~182 (1997)
  15. Czerw RJ, "Donnelly JC, Walmann JO. In vitro evaluation of the accuracy of several electronic apex locators", J Endod, 21(11), pp.572~575 (1995)
  16. Ibarrola JL, "Ludlow MO. Effect of preflaring on Root ZX apex locators", J Endod, 25(9), pp.625~626 (1999)
  17. Shabahang S, "An in vivo evaluation of Root ZX electronic apex locator", J Endod, 22(1), pp.616~618 (1996)
  18. 조영린, "하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도", 대한치과보존학회지, 30(6), pp.477~485 (2005), 대한치과보존학회
  19. Kim E, "Difference in root canal length between Asians and Caucasians", Int Endod J, 38(3), pp.149~151 (2005)
  20. Perzigian AJ, "Allometric analysis of dental variation in a human population", Am J Phys Anthropol, 54(3), pp.341~345 (1981)
  21. 조정임, "만곡근관에서 근관형성방법에 따른 근관작업장의 변화", 대한치과보존학회지, 31(1), pp.30~35 (2006), 대한치과보존학회
  22. Gulabivala K, "Root and canal morphology of Burmese mandibular molars", Int Endod J, 34(5), pp.359~370 (2001)
  23. Ng YL, "Root and canal morphology of Burmese maxillary molars", Int Endod J, 34(8), pp.620~630 (2001)
  24. Ahmed HA, "Root and canal morphology of permanent mandibular molars in a Sudanese population", Int Endod J, 40(10), pp.766~771 (2007)
  25. Pattanshetti N, "Root and canal morphology of the mesiobuccal and distal roots of permanent first molars in a Kuwait population-a clinical study", Int Endod J, 41(9), pp.755~762 (2008)
  26. Peiris HR, "Root canal morphology of mandibular permanent molars at different ages", Int Endod J, 41(10), pp.828~835 (2008)
  27. 박슬희, "하악대구치 근심치근의 협설측 근관장의 비교", 대한치과보존학회지, 29(6), pp.541~547 (2004), 대한치과보존학회

관련 논문AI추천