A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide x 2.4 m height x 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.
Abstract
A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide x 2.4 m height x 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.
참고문헌 (7)
- 강은철, "Tracepro를 활용한 이중 블라인드 광파이프 채광 시스템의 블라인드 설계 및 시스템 효율 평가", 설비공학 논문집, 24(6), pp.515~520 (2012), 대한설비공학회[DOI]
- 강은철, "원형 프레넬 집광형 POF 주광 조명시스템 성능 평가 연구", 한국태양에너지학회 논문집, 31(1), pp.31~36 (2011), 한국태양에너지학회
- 최용전, "LFLP와 DBLP 자연채광시스템의 성능평가 비교 연구", 대한기계학회논문집 B, 35(8), pp.799~804 (2011), 대한기계학회
- Alvin, W., "Development of New Solar Collection System for Light Pipe Technology", Proceedings of the KSES 2004 Spring Annual Conference (2004)
- Lee, E. J., "Light Concentration and Light Pipe Daylighting System Technologies", The Magazine of Korean Solar Energy Society, 7(1) (2008)
- Lambda Research Corporation, "TracePro User's manual Releas 3.0", ~ (2002)
- KEMCO, "Standards for New & Renewable Energy Facility-Daylight System", PV 601:2007, ~ (2007)