상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구
Three-dimensional finite element analysis on the effect of maxillary incisor torque
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis. A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, .022 x .028 Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees. The findings of this study showed that the reaction force acting on the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied, labial crown and distal tipping and intrusion of the incisors took place, and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used. NiTi or TMA wire is desirable for torque control.
Abstract
The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis. A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, .022 x .028 Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees. The findings of this study showed that the reaction force acting on the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied, labial crown and distal tipping and intrusion of the incisors took place, and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used. NiTi or TMA wire is desirable for torque control.
참고문헌 (29)
- "Biomechanics in clinical orthodontics" (1997)
- "Torque and its application to orthodontics", pp.817~30 (1959)
- "An evaluation of smiles before and after orthodontic treatment", 63, pp.183~9 (1993)
- "Alinging,leveling and torque control- pilot study", 59, pp.51~60 (1989)
- "Finishing and detailing with a preadjusted appliance system", 25, pp.251~64 (1991)
- "Simultaneous en masse retraction of maxillary incisors with lingual root torque", 4, pp.200~12 (1971)
- "Contemporary orthodontics", pp.328~9 (2000), CV Mosby
- "Rectangular wire and third-order torque:a new perspective", 113, pp.421~30 (1998)
- "On torque", 13, pp.305~12 (1979)
- "On the variability of cross sectional dimensions and torsional properties of rectangular Ni-Ti arch wire", 113, pp.546~57 (1998)
- "Mechanical properties of orthodontic wires in tension,bending and torsion", 82, pp.206~10 (1982)
- "상악호선에 torque 부여시 나타나는 상반작용에 관한 유한요소법적 연구", 24, pp.479~508 (1994)
- "An evaluation of the torsional moments developed in orthodontic applications", 105, pp.392~400 (1994)
- "교정용 각형선재에 부여된 torque가 브라켓에 발생시키는 모멘트에 관한 유한요소법적 분석", 31, pp.335~46 (2001)
- "Photoelasticity as a research technique for analyzing stresses in dental structures", 34, pp.831~8 (1955)
- "Material parameters and stress profiles within the periodontal ligament", 99, pp.427~40 (1991)
- "알기 쉬운 유한 요소 해석" (2001)
- "The role of the periodontal ligament in bone modeling:the initial development of a time-dependent finite element model", 109, pp.155~62 (1996)
- "Initial stress differences between sliding and sectional mechanics with an endosseous implant as anchorage:a 3-dimensional finite element analysis", 71, pp.247~56 (2001)
- "Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces", 92, pp.499~505 (1987)
- "Stresses induced by edgewise appliances in the periodontal ligament - a finite element study", 62, pp.15~22 (1992)
- "상악 6전치부의 후방견인시 저항중심의 수직적 위치에 관한 3차원 유한요소법적 연구", 31, pp.425~38 (2001)
- "Intrusion arch wire activation시 상악 견치에 가해진 초기응력의 유한요소법을 통한 고찰", 28, pp.391~8 (1998)
- "Space closing loop에 의해 야기되는 상악 절치부 이동양상에 관한 역학적 연구", 25, pp.143~52 (1995)
- "JCO interview on the straight wire appliance", 26, pp.493~508 (1990)
- "The thickness of the human periodontal membrane", 24, pp.1260~70 (1937)
- "Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys", 98, pp.117~26 (1990)
- "A discussion of torque force", pp.263~5
- "A mechanical evaluation of buccal segment reaction to edgewise torque", 44, pp.120~9 (1974)