본문 바로가기
KERD
논문KCI 등재

태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구

Experimental Study for Estimation of Air Heating Performance and Improvement of Thermal Performance of Hybrid Solar Air-water Heater

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류기타공학

초록

Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector’s inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about 43°C to 60°C on the 30°C of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

Abstract

Solar energy is one of the important renewable energy resources. It can be used for air heating, hot water supply, heat source of desiccant cooling system and so on. And many researches for enhancing efficiency have been conducted because of these various uses of solar thermal energy. This study was performed to investigate the air heating performance of hybrid solar air-water heater that can heat air and liquid respectively or simultaneously and finding method for improving thermal performance of this collector. This collector has both liquid pipe and air channel different with the traditional solar water and air heater. Fins were installed in the air channel for enhancing the air heating performance of collector. Also air inlet & outlet temperature, ambient temperature and solar collector’s inner part temperature were confirmed with different air velocity on similar solar irradiance. As a result, temperature of heated air was shown about 43°C to 60°C on the 30°C of ambient temperature and thermal efficiency of solar collector was shown 28% to 73% with respect to air velocity. Also, possibility of improvement of thermal performance of this collector could be ascertained from the heat transfer coefficient calculated from this experiment. Thus, it is considered that the research for finding optimal structure of hybrid solar air-water heater for enhancing thermal performance might be needed to conduct as further study based on the method for improving air heating performance confirmed in this study.

참고문헌 (8)

  1. Fatkhur, R., "An Experimental Study on the Characteristic of the Hot Water-Air Heating Generating System with a Solar Collector", Proceedings of the KSES 2012 Spring Annual Conference, pp.360~363 (2012)
  2. 최광환, "복합형 태양열 가열기 열매체 동시운전시의 열적 성능에 관한 실험적 연구", 한국태양에너지학회 논문집, 34(3), pp.115~121 (2014), 한국태양에너지학회
  3. 최휘웅, "복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가", 한국태양에너지학회 논문집, 34(6), pp.49~56 (2014), 한국태양에너지학회
  4. 최휘웅, "복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구", 한국태양에너지학회 논문집, 35(3), pp.73~80 (2015), 한국태양에너지학회
  5. Kim, J. R., "Research on the Performance of Regenerator using Hot Air from Air Heating Solar Collector(1st paper: On the Effect of Hot Air Temperature to Regeneration Rate)", Proceedings of the KSES Autumn Annual Conference, pp.18~26 (2001)
  6. Kim, B. C., "Research on the Performance of Regenerator using Hot Air From air Heating Solar Collector(2nd paper: On the Analysis of Source Effect by Experimental Desing)", Proceedings of the KSES Autumn Annual Conference, pp.27~32 (2001)
  7. Kim, D. E., "Optimum Operating Condition of Regenerator Using Air Heating Solar Collector", Proceedings of the KSES Spring Annual Conference, pp.102~107 (2002)
  8. 최휘웅, "태양열 공기난방기에서 핀의 형상에 따른 열전달 성능평가", 한국태양에너지학회 논문집, 33(6), pp.85~91 (2013), 한국태양에너지학회

관련 논문AI추천

이 간행물의 다른 논문 (7건)