초록

The solar air–water heater is a combined system of air-type and water-type collectors and a composite collector that can produce hot water and heated air in one system. Although it can maximize heat acquisition by transferring some of the heat lost from the absorbent plate and pipe toward the air duct, the heat acquisition is low due to the low heat capacity. To address this problem, several studies have been conducted using turbulent promoters in ducts. In this study, to improve the air-side heat transfer performance of the solar air–water heater, perforated fins on the bottom side of the absorption plate were arranged in various arrangements. Thereafter, computational fluid dynamics (CFD) was performed according to the flow conditions, and the heat transfer performance and pressure drop characteristics were analyzed. Results indicated that the heat transfer performance improved by at least 1.24 times to a maximum of 2.21 times, and that the pressure drop was in the range of 4.10 ~ 7.38 times, confirming the thermal hydraulic performance parameter (THPP). In the case of the performance coefficient, when perforated fins were attached side by side to the pipe, the highest performance coefficient was 1.18.

Abstract

The solar air–water heater is a combined system of air-type and water-type collectors and a composite collector that can produce hot water and heated air in one system. Although it can maximize heat acquisition by transferring some of the heat lost from the absorbent plate and pipe toward the air duct, the heat acquisition is low due to the low heat capacity. To address this problem, several studies have been conducted using turbulent promoters in ducts. In this study, to improve the air-side heat transfer performance of the solar air–water heater, perforated fins on the bottom side of the absorption plate were arranged in various arrangements. Thereafter, computational fluid dynamics (CFD) was performed according to the flow conditions, and the heat transfer performance and pressure drop characteristics were analyzed. Results indicated that the heat transfer performance improved by at least 1.24 times to a maximum of 2.21 times, and that the pressure drop was in the range of 4.10 ~ 7.38 times, confirming the thermal hydraulic performance parameter (THPP). In the case of the performance coefficient, when perforated fins were attached side by side to the pipe, the highest performance coefficient was 1.18.

참고문헌 (14)

  1. 최휘웅, "공기식 태양광", 열 시스템 공기채널 내 여러 저항체설치에 따른 전열성능에 관한 CFD 해석, 2018, pp.38(2), 33~43[DOI]
  2. 유지숙, "공기식 PVT 컬렉터에 적용된 타공 베플의 변수에 따른 열 성능 향상을 위한 연구", 한국태양에너지학회 논문집, 39(6), pp.83~91 (2019), 한국태양에너지학회[DOI]
  3. 안승용, "Y자형 리브가 태양열 공기가열기의 열전달 성능 및 압력강하에 미치는 영향", 대한기계학회논문집 B, 45(4), pp.225~235 (2021), 대한기계학회
  4. 안성후, "열전달 향상 장치에 따른 평판형 태양열 집열기의 압력강하 및 열전달 특성", 한국마린엔지니어링학회지, 37(5), pp.453~460 (2013), 한국마린엔지니어링학회[DOI]
  5. L. Abhay, "Numerical analysis on solar air collector provided with artificial square shaped roughness for indirect type solar dryer", Journal of Cleaner Production, 190, pp.353~367 (2018), Elsevier BV[DOI]
  6. A.R. Jaurker, "Heat transfer and friction characteristics of rectangular solar air heater duct using rib-grooved artificial roughness", Solar Energy, 80(8), pp.895~907 (2006), Elsevier BV[DOI]
  7. Arun Venu, A. K., "Simulation Studies on Porous Medium Integrated Dual Purpose Solar Collector", International Journal of Renewable Energy Research, 3(1), pp.114~120 (2013)
  8. Shandal, J., "Simulation Analysis of Thermal Performance of the Solar Air", Water Collector by Using Computational Fluid Dynamics, 2020, pp.180, ~
  9. Mohite, A., "Dual-Function Solar Collector", Master, Environmental Engineering, pp.2016
  10. M.T. Baissi, "Thermal behavior in a solar air heater channel roughened with delta-shaped vortex generators", Applied Thermal Engineering, 165, pp.113563~ (2020), Elsevier BV[DOI]
  11. "ANSYS Fluent 2021 R2, ANSYS Fluent Theory Guide 15" (2013)[URL]
  12. Yadav, A. S., "A CFD (Computational Fluid Dynamics) based Heat Transfer and Fluid Flow Analysis of a Solar Air Heater Provided with Circular Transverse wire Rib Roughness on the Absorber Plate", Energy, 55, pp.1127~1142 (2013)
  13. Singh, S., "CFD (Computational Fluid Dynamics) Investigation on Nusselt Number and Friction Factor of Solar Air Heater Duct Roughened with Non-uniform Cross-section Transverse Rib", Energy, 84, pp.509~517 (2015)
  14. Webb, R. L., "Forced Convection Heat Transfer in Helically Rib-roughened Tubes", International Journal of Heat and Mass Transfer, 23, pp.1127~1136 (1980)

관련 논문AI추천

태양열 공기-물 가열기의 공기 가열 성능 평가 및 열적 성능 개선을 위한 실험적 연구김영복, 손창효, 윤정인, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2017 · 제37권 제1호태양열 공기식 집열기 내 저항체 설치 위치 및 형상에 따른 열전달 및 압력강하 특성에 대한 CFD 해석문광암, 안건용, 안병화, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2025 · 제45권 제3호공기식 태양광/열 집열기 내 공기층에서 비균일 단면을 갖는 돌출부 설치 조건에 따른 전열 성능에 관한 분석김영복, 문광암, 손창효, 윤정인, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2021 · 제41권 제1호태양열 공기가열기의 흡열판 홀 배치와 형상에 따른 열적 성능에 관한 수치해석적 연구부준홍, 신재혁한국태양에너지학회 · 한국태양에너지학회 논문집2015 · 제35권 제1호복합형 태양열 가열기에서 열매체 단일운전에 따른 기기성능 평가손창효, 윤정인, 최광환, 최휘웅한국태양에너지학회 · 한국태양에너지학회 논문집2014 · 제34권 제6호공기식 태양광/열 집열기 내 저항체 형상조건과 유동 조건에 따른 열전달 성능 및 압력강하 분석김성빈, 김영복, 김준엽, 손창효, 안병화, 윤정인, 최광환한국태양에너지학회 · 한국태양에너지학회 논문집2022 · 제42권 제1호