본문 바로가기
KERD
논문KCI 등재

건물형 태양광 실증(Mock-up)을 통한 색상 및 단열재 적용에 따른 발전 성능 비교 분석

Experimental Analysis of Power Generation Performance of BIPV Mock-up Systems Considering Color and Thermal Insulation Conditions

5

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

The effects of color coating and insulation on the power generation performance of building-integrated photovoltaic (BIPV) systems were experimentally analyzed. A mock-up test bed was constructed, and the irradiance and power generation were measured for one year using south-facing modules. The analysis included colorless (reference), red (Color A), and dark blue (Color B) modules under both insulation (I) and noninsulation (NI) conditions. The output of the Color B module was higher than that of Color A owing to the higher light absorption efficiency of the shorter blue wavelengths. Under insulation conditions, the performance ratio (PR) of Color A was lower by –12% to –24% and that of Color B was lower by –2% to –10% than that of the reference, mainly owing to heat accumulation from suppressed rear heat dissipation. The power generated by BIPV modules is strongly influenced by building envelope factors, such as the coating color and insulation structure.

Abstract

The effects of color coating and insulation on the power generation performance of building-integrated photovoltaic (BIPV) systems were experimentally analyzed. A mock-up test bed was constructed, and the irradiance and power generation were measured for one year using south-facing modules. The analysis included colorless (reference), red (Color A), and dark blue (Color B) modules under both insulation (I) and noninsulation (NI) conditions. The output of the Color B module was higher than that of Color A owing to the higher light absorption efficiency of the shorter blue wavelengths. Under insulation conditions, the performance ratio (PR) of Color A was lower by –12% to –24% and that of Color B was lower by –2% to –10% than that of the reference, mainly owing to heat accumulation from suppressed rear heat dissipation. The power generated by BIPV modules is strongly influenced by building envelope factors, such as the coating color and insulation structure.

관련 논문AI추천

이 간행물의 다른 논문 (17건)