수직 외벽면 적용 BIPV의 Mock-up 실험연구
A Study on the Mock-up test for applying BIPV in the external curtain Wall
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard(950 × 980mm) large(950 × 1960mm)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.
Abstract
This research is an experimental study on BIPV Power performance of See-through a-si and Light-through applying external curtain wall. In case of See-through a-si Photovoltaic, appropriateness of facade applying standard(950 × 980mm) large(950 × 1960mm)area photovoltaic was examined. Transparent performance was also investigated through Power simulation according to angles and seasons of See-through a-si and Light-through Photovoltaic so that Power output was surveyed with using designed and manufactured Mock-up. When comparing See-through a-si to Light-through Photovoltaic for simulation Power output on angles based on full south aspect, which the result was that See-through a-si Power output according to Light-through Power output was the highest of 65.5% when applying a 90 degree angle. Monthly accumulated average Power output during winter seasons (December, January and February) applying a vertical plane on full south aspect was analyzed, which results in 66.37W/h of See-through a-si and 139.1W/h of Light-through. See-through a-si Power output showed 47.7% in comparison with Light-through transparent. Also monthly, hourly average Power efficiency according to solar radiation during winter seasons (December, January and February) was that 4.7% of See-Through a-si and 9.8% of Light-through.
참고문헌 (6)
- 임종욱, "BIPV 건물 외피시스템 개발 - Curtain Wall의 일체화 가능성을 중심으로 -", 대한건축학회논문집 계획계, 20(2), pp.169~176 (2004), 대한건축학회
- 김회서, "건축물 적용 태양광 발전 시스템의 경제성 평가에 관한 연구 -투광형 비정질 실리콘 BIPV를 중심으로-", 대한건축학회 학술발표대회 논문집, pp.973~976 (2007)
- 이한명, "투광형 비정질 BIPV 시스템의 LCC 평가에 관한 연구", 한국태양에너지학회 논문집, 29(1), pp.1~10 (2009), 한국태양에너지학회
- 윤종호, "투명 박막 태양광 창호의 경사각에 따른 발전량 실측연구", 대한건축학회논문집 계획계, 24(9), pp.271~278 (2008), 대한건축학회
- 이한명, , 석사, pp.2009
- Hway-suh, "The Exprei mental Study on the Application of the PV System in the curtain Wall", 2005 Solar World Congress