Comparative Analysis of Simulated Signal-to-Noise Ratio in Loop and Sleeve Antennas at 10.5 Tesla for Human Head Imaging
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
'Purpose: To explore the signal-to-noise ratio (SNR) of loops and sleeve antennas for human head imaging at 10.5 tesla. Materials and Methods: Simulated SNR maps were calculated using XFdtd with a resolution of 2 × 2 × 2 mm3. The 3D CAD renderings of the loop and sleeve antennas with single- , three- , and five-channels were evaluated. Each loop coil had dimensions of 35 × 50 mm2, and the length of the individual sleeves was 180 mm, with an additional 70 mm for the required coaxial sleeve balun. All SNR maps were calculated using MATLAB. These base elements were evaluated in three-loop configurations aligned in the z-direction and compared with the same number of sleeve antenna arrays spaced 15 mm apart to achieve similar coverage. This comparison was further extended to the five-channel case for both loops and sleeve antennas in arrangements that could achieve similar overall imaging coverage. Results: The single-sleeve antenna demonstrated a 17% higher SNR in close proximity to the conductor compared to a loop. A boost in SNR performance was also observed with three- and five-channel sleeve antennas with a close gap (15 mm) between the elements, as indicated. Substantial SNR improvements were mostly associated with the peripheral gains achievable with closely coupled sleeve antennas in a high-density array arrangement. Conclusion: The sleeve antenna concept supports high-density receiver antenna arrays. Due to the higher conductor density, it can result in a significant peripheral SNR gain.
Abstract
'Purpose: To explore the signal-to-noise ratio (SNR) of loops and sleeve antennas for human head imaging at 10.5 tesla. Materials and Methods: Simulated SNR maps were calculated using XFdtd with a resolution of 2 × 2 × 2 mm3. The 3D CAD renderings of the loop and sleeve antennas with single- , three- , and five-channels were evaluated. Each loop coil had dimensions of 35 × 50 mm2, and the length of the individual sleeves was 180 mm, with an additional 70 mm for the required coaxial sleeve balun. All SNR maps were calculated using MATLAB. These base elements were evaluated in three-loop configurations aligned in the z-direction and compared with the same number of sleeve antenna arrays spaced 15 mm apart to achieve similar coverage. This comparison was further extended to the five-channel case for both loops and sleeve antennas in arrangements that could achieve similar overall imaging coverage. Results: The single-sleeve antenna demonstrated a 17% higher SNR in close proximity to the conductor compared to a loop. A boost in SNR performance was also observed with three- and five-channel sleeve antennas with a close gap (15 mm) between the elements, as indicated. Substantial SNR improvements were mostly associated with the peripheral gains achievable with closely coupled sleeve antennas in a high-density array arrangement. Conclusion: The sleeve antenna concept supports high-density receiver antenna arrays. Due to the higher conductor density, it can result in a significant peripheral SNR gain.
참고문헌 (32)
- Pohmann R, "Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9. 4 tesla using current receive coil arrays", Magn Reson Med, 75, pp.801~809 (2016)
- Ugurbil K, "Magnetic resonance imaging at ultrahigh fields", IEEE Trans Biomed Eng, 61, pp.1364~1379 (2014)
- Moser E, "7-T MR—from research to clinical applications?", NMR Biomed, 25, pp.695~716 (2012)
- Vu AT, "High resolution whole brain diffusion imaging at 7T for the human connectome project", Neuroimage, 122, pp.318~331 (2015)
- Ogawa S, "Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model", Biophys J, 64, pp.803~812 (1993)
- Ug˘urbil K, "Imaging at ultrahigh magnetic fields : history, challenges, and solutions", Neuroimage, 168, pp.7~32 (2018)
- Ug˘urbil K, "Brain imaging with improved acceleration and SNR at 7 tesla obtained with 64-channel receive array", Magn Reson Med, 82, pp.495~509 (2019)
- Griswold MA, "Generalized autocalibrating partially parallel acquisitions(GRAPPA)", Magn Reson Med, 47, pp.1202~1210 (2002)
- Pruessmann KP, "SENSE : sensitivity encoding for fast MRI", Magn Reson Med, 42, pp.952~962 (1999)
- Kang CK, "Intracranial microvascular imaging at 7 T MRI with transceiver RF coils", Magn Reson Imaging, 32, pp.1133~1138 (2014)
- Shajan G, "A 16-channel dual-row transmit array in combination with a 31-element receive array for human brain imaging at 9. 4 T", Magn Reson Med, 71, pp.870~879 (2014)
- Wiggins GC, "32-channel 3 tesla receive-only phased-array head coil with soccer-ball element geometry", Magn Reson Med, 56, pp.216~223 (2006)
- Woo MK, "Extended monopole antenna array with individual shield(EMAS)coil : an improved monopole antenna design for brain imaging at 7 tesla MRI", Magn Reson Med, 75, pp.2566~2572 (2016)
- Woo MK, "Evaluation of 8-channel radiative antenna arrays for human head imaging at 10. 5 tesla", Sensors(Basel), 21, pp.6000~ (2021)
- Woo MK, "A 16-channel dipole antenna array for human head magnetic resonance imaging at 10. 5 tesla", Sensors(Basel), 21, pp.7250~ (2021)
- Raaijmakers AJ, "Design of a radiative surface coil array element at 7 T : the single-side adapted dipole antenna", Magn Reson Med, 66, pp.1488~1497 (2011)
- Raaijmakers AJ, "The fractionated dipole antenna : a new antenna for body imaging at 7 tesla", Magn Reson Med, 75, pp.1366~1374 (2016)
- Lattanzi R, "Approaching ultimate intrinsic signal-to-noise ratio with loop and dipole antennas", Magn Reson Med, 79, pp.1789~1803 (2018)
- Pfrommer A, "The ultimate intrinsic signal-to-noise ratio of loop-and dipole-like current patterns in a realistic human head model", Magn Reson Med, 80, pp.2122~2138 (2018)
- "A 16-channel transceiver loop+dipole antennas head array for human head imaging at 10.5T"[URL]
- Woo MK, "Evaluation of a 16-channel transceiver loop + dipole antenna array for human head imaging at 10. 5 tesla", IEEE Access, 8, pp.203555~203563 (2020)
- Woo MK, "A 32-channel sleeve antenna receiver array for human head MRI applications at 10. 5 T", IEEE Trans Med Imaging, 42, pp.2643~2652 (2023)
- Woo MK, "Comparison of 16-channel asymmetric sleeve antenna and dipole antenna transceiver arrays at 10. 5 tesla MRI", IEEE Trans Med Imaging, 40, pp.1147~1156 (2021)
- Fujita H, "RF surface receive array coils : the art of an LC circuit", J Magn Reson Imaging, 38, pp.12~25 (2013)
- "A novel 16-channel transmitter/32-channel receiver combined sleeve antenna and dipole array for the human whole brain imaging at 10.5 tesla"[URL]
- Budé LMI, "The coax monopole antenna : a flexible end-fed antenna for ultrahigh field transmit", receive arrays, 2024, pp.92, 361~373
- Ianniello C, "Synthesized tissue-equivalent dielectric phantoms using salt and polyvinylpyrrolidone solutions", Magn Reson Med, 80, pp.413~419 (2018)
- Tavaf N, "A self-decoupled 32-channel receive array for human-brain MRI at 10. 5 T", Magn Reson Med, 86, pp.1759~1772 (2021)
- "Approaching the ultimate intrinsic SNR with dense arrays of electric dipole antennas"[URL]
- Avdievich NI, "Evaluation of transmit efficiency and SAR for a tight fit transceiver human head phased array at 9.4 T", NMR Biomed, 30, pp.e3680~ (2017)
- "29-channel receive-only dense dipole head array for 7T MRI"[URL]
- Woo MK, "A monopole and dipole hybrid antenna array for human brain imaging at 10. 5 tesla", IEEE Antennas Wirel Propag Lett, 21, pp.1857~1861 (2022)
