본문 바로가기
KERD
논문KCI 등재

승마 보법별 신체활동 측정도구에 따른 에너지소비량 비교

Comparison of Energy Expenditure for Walking Steps of Horse and Physical Activity Assessment Instruments in Horse Riding Exercise

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

PURPOSE: The aim of this study was to compare the energy expenditure for 3 walking steps of horse and 3 physical activity assessment instruments (Armband, GT1M and GT3X) in horse riding exercise. METHODS: For this purpose, 9 men participants in their 20s who had over 3 years horse riding experiences at S horse-riding tract in Gyeonggi-do and had a qualification of leisure sport instructors (horse riding) were selected for the study. The measurement was taken place at the indoor horse riding track with 25 m wide and 37 m long. For a criterion test, the energy expenditure measurement method by the respiratory gas analysis was employed. The horse riding exercise type during the measurement consists of walk, trot and canter, 6 minutes walk, 6 minutes rest on horse, 6 minutes trot, 6 minutes rest on horse and 6 minute canter were taken place. RESULTS: Compared with the rest of footwork specific energy consumption of horse riding, walk viewing approximately 1.6 times, trot is about 3.2 times, 4.4 times higher canter appeared, showed significant differences in all the footwork (F=39.492, p<.001). Compared with the results of K4b2 the criterion test instrument in the difference between the energy expenditure assessment instruments, in the case of walk Armband 1.6 times, GT1M 1.6 times, GT3X about 2.2 times both showed a overestimated (F=48.536, p<.001), about 2.1 times Armband case of trot, GT1M about 2.4 times, GT3X approximately 2.4 times (F=255.637, p<.001), about 1.2 times Armband case of a canter, GT1M about 2.7 times, GT3X 2.8 times were overestimated (F=417.841, p<.001). CONCLUSIONS: This study demonstrated that other energy expenditure assessment instruments (Armband, GT1M and GT3X) were overestimated in overall compared with the criterion test instrument. Following-study on seeking the energy consumption measurement method, excluding the influence of the horse and the wearing position of the measurement tool that can improve the accuracy is determined to be necessary.

Abstract

PURPOSE: The aim of this study was to compare the energy expenditure for 3 walking steps of horse and 3 physical activity assessment instruments (Armband, GT1M and GT3X) in horse riding exercise. METHODS: For this purpose, 9 men participants in their 20s who had over 3 years horse riding experiences at S horse-riding tract in Gyeonggi-do and had a qualification of leisure sport instructors (horse riding) were selected for the study. The measurement was taken place at the indoor horse riding track with 25 m wide and 37 m long. For a criterion test, the energy expenditure measurement method by the respiratory gas analysis was employed. The horse riding exercise type during the measurement consists of walk, trot and canter, 6 minutes walk, 6 minutes rest on horse, 6 minutes trot, 6 minutes rest on horse and 6 minute canter were taken place. RESULTS: Compared with the rest of footwork specific energy consumption of horse riding, walk viewing approximately 1.6 times, trot is about 3.2 times, 4.4 times higher canter appeared, showed significant differences in all the footwork (F=39.492, p<.001). Compared with the results of K4b2 the criterion test instrument in the difference between the energy expenditure assessment instruments, in the case of walk Armband 1.6 times, GT1M 1.6 times, GT3X about 2.2 times both showed a overestimated (F=48.536, p<.001), about 2.1 times Armband case of trot, GT1M about 2.4 times, GT3X approximately 2.4 times (F=255.637, p<.001), about 1.2 times Armband case of a canter, GT1M about 2.7 times, GT3X 2.8 times were overestimated (F=417.841, p<.001). CONCLUSIONS: This study demonstrated that other energy expenditure assessment instruments (Armband, GT1M and GT3X) were overestimated in overall compared with the criterion test instrument. Following-study on seeking the energy consumption measurement method, excluding the influence of the horse and the wearing position of the measurement tool that can improve the accuracy is determined to be necessary.

참고문헌 (23)

  1. Bouten CV, "Assessment of energy expenditure for physical activity using a triaxial accelerometer", Medicine and Science in Sports and Exercise, 26(12), pp.1516~1523 (1994)
  2. Brooks GA, "Estimation of anaerobic energy production and efficiency in rate during exercise", Journal of Applied Physiology, 56(2), pp.520~525 (1984)
  3. Calabro MA, "Validation of the SenseWear Pro Armband algorithms in children", Medicine and Science in Sports and Exercise, 41(9), pp.1714~1720 (2009)
  4. Devienne MFM, "Energy expenditure of horse riding", European Journal of Applied Physiology, 82(5-6), pp.499~503 (2000)
  5. Freedson PS, "Calibration of the Computer Science and Applications, Inc. accelerometer", Medicine and Science in Sports and Exercise, 30(5), pp.777~781 (1998)
  6. 전혜자, "지적 장애인과 휠체어 장애인의 신체활동 검사타당도", 한국여성체육학회지, 22(2), pp.203~214 (2008), 한국여성체육학회
  7. Kim DY, "Validation of Sense Wear Pro2 Armband and Energy Cost for Jackstone and Hoop Activities", Joumal of Korea Sport Research, 20(6), pp.59~70 (2009)
  8. King GA, "Comparison of activity monitors to estimate energy cost of treadmill exercise", Medicine and Science in Sports and Exercise, 36(7), pp.1255~1251 (2004)
  9. Korea Equestrian Federation, "EQUESTRIAN", pp.66~70 (2009), Seongmun TDP
  10. Korean Horse Affairs Association, "Horse riding lecturing gurn teaching material" (2010), Yeolrimaedeuwon
  11. Lee MH, "Development of Estimated Equation of Exercise Intensity for Children Using Triaxial Accelerometry", 석사, pp.2012
  12. 이미영, "객관적 신체활동 검사도구의 타당도 증거와 검증 절차: 체계적 문헌분석", 한국체육측정평가학회지, 13(2), pp.17~37 (2011), 한국체육측정평가학회
  13. Maliszewski AF, "Validity of the caltrac accelerometer in estimating energy expenditure and activity in children and adults", Pediatric Exercise Science, 3(2), pp.141~151 (1991)
  14. McArdle W, "Exercise physiology" (2001), Williams and Willikins
  15. Meijer GA, "Assessment of energy expenditure by recording hear rate and body acceleration", Medicine and Science in Sports and Exercise, 21(3), pp.343~347 (1989)
  16. "Advanced equestrian sports to enjoy in the near Seoul"[URL]
  17. Rowlands AV, "Validation of the RT3 Triaxial accelerometer for the assessment of physical activity", Medicine and Science in Sports and Exercise, 36(3), pp.518~524 (2004)
  18. Sallis JF, "Bias in estimating caloric expenditure from physical activity in children", Sports Medicine, 11(4), pp.203~209 (1991)
  19. "Is popularized...Let's enjoy with horse riding umbilical cord"[URL]
  20. 성봉주, "승마시뮬레이터의 보행형태에 따른 청·장년의 심박수, 산소섭취량, 분당 환기량, MET, 칼로리소비량의 변화", 체육과학연구, 15(1), pp.1~13 (2004), 국민체육진흥공단 부설 한국스포츠개발원
  21. Westerling D, "A study of physical demands in riding", European Journal of Applied Physiology, 50(3), pp.378~382 (1983)
  22. Welsman JR, "Daily physical activity and blood lactate indices of aerobic fitness in children", British Journal of Sports Medicine, 26(4), pp.228~232 (1992)
  23. 유동화, "말의 보행형태에 따른 승마의 운동강도", 석사, 스포츠과학과, pp.2014

관련 논문AI추천

이 간행물의 다른 논문 (10건)