Accuracy of Horse-Riding Energy Consumption according to Accelerometer Wearing Location
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The purpose of this study is to verify the accuracy of energy consumption per wearing location (waist, wrist, ankle) of uniaxial accelerometer (GT1M) during horse-riding exercise (normal-walking, fast-walking, running). The study subjects were conveniently sampled from 11 males in their 20s from S horse-riding course who have over 3 years of experience in horse-riding and are licensed as leisure sports instructors (horse-riding), and the following conclusion was drawn. For normal-walking, there was no significant difference of standard energy consumption among waist, wrist, and ankle, and all three locations showed confidence interval with small deviation in Bland-Altman Plot. On the other hand, for fast-walking and running, only wrist showed no significant difference, where only wrist location showed low-deviation confidence interval in Bland-Altman Plot. According to such results, the accuracy was relatively high for wrist-wearing when predicting horse-riding activity energy consumption using accelerometer. Therefore, the wearing location must be considered when predicting horse-riding activity energy consumption with accelerometer on site.
Abstract
The purpose of this study is to verify the accuracy of energy consumption per wearing location (waist, wrist, ankle) of uniaxial accelerometer (GT1M) during horse-riding exercise (normal-walking, fast-walking, running). The study subjects were conveniently sampled from 11 males in their 20s from S horse-riding course who have over 3 years of experience in horse-riding and are licensed as leisure sports instructors (horse-riding), and the following conclusion was drawn. For normal-walking, there was no significant difference of standard energy consumption among waist, wrist, and ankle, and all three locations showed confidence interval with small deviation in Bland-Altman Plot. On the other hand, for fast-walking and running, only wrist showed no significant difference, where only wrist location showed low-deviation confidence interval in Bland-Altman Plot. According to such results, the accuracy was relatively high for wrist-wearing when predicting horse-riding activity energy consumption using accelerometer. Therefore, the wearing location must be considered when predicting horse-riding activity energy consumption with accelerometer on site.
참고문헌 (30)
- 강동원, "가속도계의 부착위치에 따른 에너지 소비량의 예측 정확도에 관한 연구", 한국운동역학회지, 19(1), pp.179~186 (2009), 한국운동역학회
- Jun-Geun Park, "Verification of validity per device for measuring energy consumption during horse-riding activity", master, pp.2013
- Bong-Ju Seong, "Changes in heart rate, oxygen intake, ventilation amount per minute, MET, and calorie consumption of young adults according to walking patterns of horse-riding simulator", Sport Science Research, 15(1), pp.1~13 (2004)
- Dong-Hwa Yu, "Exercise intensity of horse-riding according to horse walking patterns", master, pp.2014
- Gyeong-Ok Lee, "Measurements and evaluations of physical activity for health-related study" (2006), Daehan Media
- 이미현, "GT1M과 GT3X가속도계의 신체활동량 추정 타당도 평가", 한국체육측정평가학회지, 14(2), pp.61~71 (2012), 한국체육측정평가학회[DOI]
- Mi-Ja Lim, "Study on energy consumption of physical activity and heart-rate and blood lactic acid concentration during maximum load exercise", Korean Society for the Study of Obesity, 10(04), pp.42~58 (2001)
- Korea Racing Authority, "Horse-riding trainer material" (2010), Yeolim Ad-One
- "Growing horse industry; horse-riding population surpasses 40,000" (2015)[URL]
- Center for Disease Control and Prevention, "National Youth Fitness Survey (NYFS) Physical Activity Moniter (PMA) Procedures Manual", National Health and Nutrition Examination Survey, 5~47 (2012)
- Chen, K. Y., "The technology of accelerometry-based activity monitors: current and future", Medicine and Science in Sports and Exercise, 37(11Suppl), pp.490~500 (2005)
- Devienne, M. F. M., "Energy expenditure of horse riding", European Journal of Applied Physiology, 82(5-6), pp.499~503 (2000)
- Eisenmann, J. C., "Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise", Journal of Sports Medicine and Physical Fitness, 43(2), pp.150~155 (2003)
- Freedson, P. S., "Calibration of the Computer Science and Applications, Inc. accelerometer", Medicine and Science in Sports and Exercise, 30(5), pp.777~781 (1998)
- Harrell, J. S., "Energy costs of physical activities in children and adolescents", Medicine and Sciencein Sports and Exercise, 37(2), pp.329~336 (2005)
- Liao, L. T., "Acceleration on different body positions during running on a treadmill", ISBS Conference 2008 (2008)
- Lyden, K., "A comprehensive evaluation of commonly used accelerometer energy expenditure and MET prediction equations", European Journal of Applied Physiology, 111(2), pp.187~201 (2011)
- McLaughlin, J. E., "Validation of the COSMED K4b2 portable metabolic system", International Journal of Sports Medicine, 22, pp.280~284 (2001)
- Murphy, S. L., "Revirw og physical measurement using accelerometers in older adults : Considerations for research design and conduct", Preventive Medicine, 48(2), pp.108~114 (2009)
- Pate, R. R., "Validation and Calibration of an Accelerometer in Preschool Children", Obesity, 14(11), pp.2000~2006 (2006)
- Pfeiffer, K. A., "Validation and Calibration of the actical accelerometer in preschool children", Medicine and Science in Sports and Exercise, 38(1), pp.152~157 (2006)
- Rawson, E. S., "Estimation of resistance exercise energy expenditure using accelerometry", Medicine and science in sports and exercise, 42(3), pp.622~628 (2010)
- Rosenberger, M. E., "Estimating Activity and Sedentary Behavior from an Accelerometer on the Hip or Wrist", Medicine and Science in Sports and Exercise, 45(5), pp.964~975 (2013)
- Sasaki, J. E., "Validation and comparison of ActiGraph activity monitors", Journal of Science and Medicine in Sport, 14(5), pp.411~416 (2011)
- Schmitz, K. H., "Predicting energy expenditure from accelerometry counts in adolescent girls", Medicine and Science in Sports and Exercise, 37(1), pp.155~161 (2005)
- Swartz, A. M., "Estimation of energy expenditure using CSA accelerometers at hip and wrist sites", Medicine and Science in Sports and Exercise, 32(9), pp.450~456 (2000)
- Tanaka, C., "Triaxial accelerometry for assessment of physical activity in young children", Obesity, 15(5), pp.1233~1241 (2007)
- Treuth, M. S., "Defining Accelrometer Trescholds for Activity Intensities in Adolescent Girls", Medicine and Science in Sports and Exercise, 36(7), pp.1259~1266 (2004)
- Trost, S. G., "Validity of the computer science and applications(CSA)activity monitor in children", Medicine and Science in Sports and Exercise, 30(4), pp.629~633 (1998)
- Trost, S. G., "Predictive validity of three ActiGraph energy expenditure equations for children", Medicine and Science in Sports and Exercise, 38(2), pp.380~387 (2006)
