PURPOSE: The purpose of this study is to compare the differences between ACSM equation and energy expedition equipment of college students during walking and running, and to analyze the correlation. METHODS: The subjects were 36 college students (19 male, 17 female) and they performed walking (4 km/h, 2%) and running (9.0 km/h, 2%) for 10 minutes. Energy consumption was measured using ACSM equation, Caltrac, Polar, Omron, Lifecorder, and Pacer. The paired t-test, correlation and ANOVA were conducted. RESULTS: For GEE, all 3 equipments overestimated from 116.1% to 123.4% (p<.01) and showed a significant correlation with ACSM equation in walking. Polar was showing similarly, Polar and Lifecorder showed a significant correlation with ACSM equation in running. Considering the mean comparison, Lifecorder was the most similar in walking, Polar in running, and both showed significant correlation. For NEE, only Caltrac was similar with ACSM equation in walking, Caltrac and Pacer were similar in running, but both Caltrac and Pacer didn’t have significant correlation. Omron and Pacer were relatively similar with ACSM equation in walking. All of equipment had large errors or lower correlation in running. CONCLUSIONS: Compared to ACSM equation, Caltrac and Polar were slightly overestimated, while the Pedometer was similar to for walking but very underestimated for running. The 5 of 7 cases showed significant correlations in walking, and only Polar and Lifecorder showed significant correlations in running. Therefore, it is necessary to verify the validity of the equipments continuously.

Abstract

PURPOSE: The purpose of this study is to compare the differences between ACSM equation and energy expedition equipment of college students during walking and running, and to analyze the correlation. METHODS: The subjects were 36 college students (19 male, 17 female) and they performed walking (4 km/h, 2%) and running (9.0 km/h, 2%) for 10 minutes. Energy consumption was measured using ACSM equation, Caltrac, Polar, Omron, Lifecorder, and Pacer. The paired t-test, correlation and ANOVA were conducted. RESULTS: For GEE, all 3 equipments overestimated from 116.1% to 123.4% (p<.01) and showed a significant correlation with ACSM equation in walking. Polar was showing similarly, Polar and Lifecorder showed a significant correlation with ACSM equation in running. Considering the mean comparison, Lifecorder was the most similar in walking, Polar in running, and both showed significant correlation. For NEE, only Caltrac was similar with ACSM equation in walking, Caltrac and Pacer were similar in running, but both Caltrac and Pacer didn’t have significant correlation. Omron and Pacer were relatively similar with ACSM equation in walking. All of equipment had large errors or lower correlation in running. CONCLUSIONS: Compared to ACSM equation, Caltrac and Polar were slightly overestimated, while the Pedometer was similar to for walking but very underestimated for running. The 5 of 7 cases showed significant correlations in walking, and only Polar and Lifecorder showed significant correlations in running. Therefore, it is necessary to verify the validity of the equipments continuously.

참고문헌 (29)

  1. Lloyd-Jones DM, "Defining and setting national goals for cardiovascular health promotion and disease reduction : the American Heart Association’s strategic Impact Goal through 2020 and beyond", Circulation, 121(4), pp.586~613 (2010)
  2. Go AS, "Executive summary : heart disease and stroke statistics-2014 update : a report from the American Heart Association", Circulation, 129(3), pp.399~410 (2014)
  3. Troiano RP, "Physical activity in the United States measured by accelerometer", Med Sci Sports Exerc, 40(1), pp.181~ (2008)
  4. Colbert LH, "Comparative validity of physical activity measures in older adults", Med Sci Sports Exerc, 43(5), pp.867~876 (2011)
  5. Welk GJ, "A comparative evaluation of three accelerometry-based physical activity monitors", Med Sci Sports Exerc, 32(9 Suppl), pp.S489~497 (2000)
  6. 조용현, "호흡가스분석기와 활동량계로 측정한 에너지소비량의 비교", 한국체육학회지, 55(4), pp.517~525 (2016), 한국체육학회
  7. Bassett DR, "Step counting : a review of measurement considerations and health-related applications", Sports Med, 47(7), pp.1303~1315 (2017)
  8. Tudor-Locke C, "Pedometry methods for assessing free-living adults", J Phys Act Health, 8(3), pp.445~453 (2011)
  9. Lee JM, "Validity of consumer-based physical activity monitors", Med Sci Sports Exerc, 46(9), pp.1840~1848 (2014)
  10. Sallis JF, "The Caltrac accelerometer as a physical activity monitor for school-age children", Med Sci Sports Exerc, 22(5), pp.698~703 (1990)
  11. Montoye AH, "Energy expenditure prediction using raw accelerometer data in simulated free living", Med Sci Sports Exerc, 47(8), pp.1735~1746 (2015)
  12. Ainsworth B, "The current state of physical activity assessment tools", Prog Cardiovasc Dis, 57(4), pp.387~395 (2015)
  13. American College of Sports Medicine, "ACSM’s guidelines for exercise testing and prescription", pp.2~15 (2014), Lippincott Williams & Wilkins
  14. Filardo RD, "Validation of the ACSM walking and running metabolic equations among men aged 20 to 30 years", Revista Brasileira De Medicina Do Esporte, 14(6), pp.523~527 (2008)
  15. Hall C, "Energy expenditure of walking and running : comparison with prediction equations", Med Sci Sports Exerc, 36(12), pp.2128~2134 (2004)
  16. Swan PD, "Energy expenditure estimates of the Caltrac accelerometer for running, race walking, and stepping", Br J Sports Med, 31(3), pp.235~239 (1997)
  17. Crouter SE, "Accuracy of polar S410 heart rate monitor to estimate energy cost of exercise", Med Sci Sports Exerc, 36(8), pp.1433~1439 (2004)
  18. Hansen AW, "Validation of an Internet-based long version of the International Physical Activity Questionnaire in Danish adults using combined accelerometry and heart rate monitoring", J Phys Act Health, 11(3), pp.654~664 (2014)
  19. Abel MG, "Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults", Appl Physiol Nutr Metab, 33(6), pp.1155~1164 (2008)
  20. Van Holle V, "Assessment of physical activity in older Belgian adults : validity and reliability of an adapted interview version of the long International Physical Activity Questionnaire(IPAQ-L)", BMC Public Health, 15(1), pp.433~ (2015)
  21. Medina C, "Validity and reliability of the International Physical Activity Questionnaire among adults in Mexico", Rev Panam Salud Publica, 34(1), pp.21~28 (2013)
  22. Brugniaux JV, "Polar Activity Watch 200 : a new device to accurately assess energy expenditure", Br J Sports Med, 44(4), pp.245~249 (2010)
  23. Balogun JA, "Calorimetric validation of the Caltrac accelerometer during level walking", Phys Ther, 69(6), pp.501~509 (1989)
  24. Mynarski W, "Energy expenditure of nordic walking and conventional walking assessed by accelerometer", Biomedical Human Kinetics, 6(1) (2014)
  25. Mynarski W, "Declared and real physical activity in patients with type 2 diabetes mellitus as assessed by the international physical activity questionnaire and caltrac accelerometer monitor : a potential tool for physical activity assessment in patients with type 2 diabetes mellitus", Diabetes Res Clin Pract, 98(1), pp.46~50 (2012)
  26. Hasson RE, "Validity of the Omron HJ-112 pedometer during treadmill walking", Med Sci Sports Exerc, 41(4), pp.805~809 (2009)
  27. Abel MG, "Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults", Appl Physiol Nutr Metab, 33(6), pp.1155~1164 (2008)
  28. Adam Noah J, "Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry", J Med Eng Technol, 37(7), pp.456~462 (2013)
  29. Bassett DR Jr, "Step counting : a review of measurement considerations and health-related applications", Sports Med, 47(7), pp.1303~1315 (2017)

관련 논문AI추천

이 간행물의 다른 논문 (8건)