Thermal Property Measurement of Swine Atrium

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Thermal conductivity, thermal diffusivity were measured in the atrium of a swine heart. Radiofrequency (RF) catheter ablation in an atrium has rapidly emerged at the treatment of symptomatic reentrant arrhythmia associated with accessory pathway or Atrioventricular (AV ) node conduction. The thermal properties of an atrium are definitely necessary for these treatments because, in thermal treatments, conductivity and diffusivity are significant factors in the relationship between the applied RF power and the resulting atrium temperature rise. Thermal properties were measured using a self-heated thermistor probe. Thermistor probes were inserted into the tissue of interest and were used to supply heat within the tissue as well as to monitor the temperature rise in the tissue. The measurements were performed at temperatures of 25, 37, 50℃. Atrium thermal conductivity ranged from 5.17 ± 0.12 mW/cm℃at 25℃ to 5.33 ± 0.08 mW/cm℃ at 37℃. Atrium thermal diffusivity ranged from 0.00132 ± 0.00007 cm2/sec at 25℃ to 0.00138 ± 0.00003 cm2/sec at 50℃. This paper also present the thermal property comparison of both chambers of a heart (ventricle and atria).

Abstract

Thermal conductivity, thermal diffusivity were measured in the atrium of a swine heart. Radiofrequency (RF) catheter ablation in an atrium has rapidly emerged at the treatment of symptomatic reentrant arrhythmia associated with accessory pathway or Atrioventricular (AV ) node conduction. The thermal properties of an atrium are definitely necessary for these treatments because, in thermal treatments, conductivity and diffusivity are significant factors in the relationship between the applied RF power and the resulting atrium temperature rise. Thermal properties were measured using a self-heated thermistor probe. Thermistor probes were inserted into the tissue of interest and were used to supply heat within the tissue as well as to monitor the temperature rise in the tissue. The measurements were performed at temperatures of 25, 37, 50℃. Atrium thermal conductivity ranged from 5.17 ± 0.12 mW/cm℃at 25℃ to 5.33 ± 0.08 mW/cm℃ at 37℃. Atrium thermal diffusivity ranged from 0.00132 ± 0.00007 cm2/sec at 25℃ to 0.00138 ± 0.00003 cm2/sec at 50℃. This paper also present the thermal property comparison of both chambers of a heart (ventricle and atria).

참고문헌 (15)

  1. J.C.Chato, "A Method for the Measurement of Thermal Properties of Biologic Materials", Symposium on Thermal Problems in Biotechnology,ASME,New York,LCN068-58741,pp.16-25, pp.16~25 (1968)
  2. T. A. Balasubramaniam, "Thermal Conductivity and Thermal Diffusivity of Biomaterials:A Simultaneous Measurement Technique", Journal of Biomechanical Engineering, 99, pp.148~154 (1977)
  3. M.M.Chen, "Pulse-Decay Method for Measuring the Thermal Conductivity of Living Tissue", Journal of Biomechanical Engineering, 103, pp.253~260 (1981)
  4. J. W. Valvano, "The Simultaneous Measurement of Thermal Conductivity,Thermal Diffusivity,and Perfusion in Small volumes of Tissue", Journal of Biomechanical Engineering, 106, pp.192~197 (1984)
  5. J.W.Valvano, "Thermal Conductivity and Diffusivity of Biomaterials Measured with Self-Heated Thermistors", Interna- tional Journal of Thermophysics, pp.301~311 (1985)
  6. H.F.Bowman, "Estimation of Tissue Blood Flow", pp.193~230 (1985), in Heat Transfer in Medicine and Biology,Plenum Pub.,Shitzer and Eberhart(ed.),pp.193-230
  7. H.Arkin, "Thermal Pulse Decay Method for Simultaneous Measurement of Local Thermal Conductivity and Blood Perfusion:A Theoretical Analysis", Journal of Biomechanical Engineering, 108, pp.208~214 (1986)
  8. M .S. Lee, "A Basic Study on the Estimation of Noninvasive Temperature Distribution in Carcinomo Cell for the Hyperthermia", Journal of Biomedical Engineering Research, 1, pp.11~20 (1986)
  9. J. W. Valvano, "Thermal Conductivity and Diffusivity of Arterial Wall and Atherosclerotic Plaque", Lasers in the Life Sciences, 1, pp.219~229 (1987)
  10. P.A.Patel, "A Self-Heated Thermistor Technique to Measure Effective Thermal Properties from the Tissue Surface", Journal of Biomechanical Engineering, 109, pp.330~335 (1987)
  11. J.W.Valvano, "Low Temperature Tissue Thermal Properties", Low Temperature Biotechnology American Society of Mechanical Engineers Heat Transfer Division, 98, pp.331~346 (1988)
  12. J. W. Valvano, "Temperature Measurements in Advances in Heat Transfer", pp.393~ (1992), Academic Press, Inc
  13. N.C.Bhavaraju, "Thermophysical Properties of Swine Myoca-rdium", Journal of Thermophysics, 20(2) (1999)
  14. 김경섭, "Microwave Radiometry 원리를 이용한 생체 내부 온도 추정", 의공학회지, 27(6), pp.357~364 (2006), 대한의용생체공학회
  15. 문우석, "냉 · 온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향", 의공학회지, 23(6), pp.467~475 (2002), 대한의용생체공학회

관련 논문AI추천

온도 조절형 고주파 시스템 및 식염수 분사를 고려한 전극도자절제술용 전극의 수치 모델 개발김경아, 김영진, 문진희, 안진우, 이승아, 정하철, 차은종대한의용생체공학회 · 의공학회지2017 · 제38권 제6호The Effect of Cryoinjury on Ventricular Tachycardia in the Swine Right Ventricle김성순, 김일권, 이문형, 정보영, Zhengzhe Xu연세대학교의과대학 · Yonsei Medical Journal2006 · 제47권 제5호적외선 투과 광섬유를 이용한 고주파 열치료 과정에서의 온도분포 측정문주현, 박병기, 서정기, 신상훈, 유욱재, 이봉수, 장경원, 조동현, 탁계래한국센서학회 · 센서학회지2008 · 제17권 제6호Is electrocardiogram-gated irreversible electroporation still effective in liver ablation? A validation study in swine liver irreversible electroporation modelEdward Wolfgang Lee, Peng-Xu Ding, Thanh Luong소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2023 · 제12권 제3호Non-Invasive in vivo Loss Tangent Imaging: Thermal Sensitivity Estimation at the Larmor Frequency김동현, 김민오, 신재욱, 이준성, 최나래대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2016 · 제20권 제1호MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes김형중, 우응제, 정우철, Atul S. Minhas, Tae Hwi Lee, Young Tae Kim대한의용생체공학회 · 의공학회지2008 · 제29권 제6호

이 간행물의 다른 논문 (10건)