본문 바로가기
KERD
논문KCI 등재

무선 보행 분석을 위한 블루투스 기반 관성 측정 장치의 활용 타당성 분석

Validation on the Application of Bluetooth-based Inertial Measurement Unit for Wireless Gait Analysis

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The purpose of this paper is to review the validation on the application of low frequency IMU(Inertial Measurement Unit) sensors by replacing high frequency motion analysis systems. Using an infrared-based 3D motion analysis system and IMU sensors (22 Hz) simultaneously, the gait cycle and knee flexion angle were measured. And the accuracy of each gait parameter was compared according to the statistical analysis method. The Bland-Altman plot analysis method was used to verify whether proper accuracy can be obtained when extracting gait parameters with low frequency sensors. As a result of the study, the use of the new gait assessment system was able to identify adequate accuracy in the measurement of cadence and stance phase. In addition, if the number of gait cycles is increased and the results of body anthropometric measurements are reflected in the gait analysis algorithm, is expected to improve accuracy in step length, walking speed, and range of motion measurements. The suggested gait assessment system is expected to make gait analysis more convenient. Furthermore, it will provide patients more accurate assessment and customized rehabilitation program through the quantitative data driven results.

Abstract

The purpose of this paper is to review the validation on the application of low frequency IMU(Inertial Measurement Unit) sensors by replacing high frequency motion analysis systems. Using an infrared-based 3D motion analysis system and IMU sensors (22 Hz) simultaneously, the gait cycle and knee flexion angle were measured. And the accuracy of each gait parameter was compared according to the statistical analysis method. The Bland-Altman plot analysis method was used to verify whether proper accuracy can be obtained when extracting gait parameters with low frequency sensors. As a result of the study, the use of the new gait assessment system was able to identify adequate accuracy in the measurement of cadence and stance phase. In addition, if the number of gait cycles is increased and the results of body anthropometric measurements are reflected in the gait analysis algorithm, is expected to improve accuracy in step length, walking speed, and range of motion measurements. The suggested gait assessment system is expected to make gait analysis more convenient. Furthermore, it will provide patients more accurate assessment and customized rehabilitation program through the quantitative data driven results.

참고문헌 (18)

  1. Drewett RF, "Measuring outcome of total knee replacement using quality of life indices", Annals of the royal college of surgeons of england, 74(4), pp.286~ (1992)
  2. Kirwan J, "Overall long-term impact of total hip and knee joint replacement surgery on patients with osteoarthritis and rheumatoid arthritis", Rheumatology, 33(4), pp.357~360 (1994)
  3. Rorabeck CH, "The cost benefit of total knee arthroplasty", Orthopedics, 19(9), pp.777~779 (1996)
  4. Labraca NS, "Benefits of starting rehabilitation within 24 hours of primary total knee arthroplasty : randomized clinical trial", Clinical rehabilitation, 25(6), pp.557~566 (2011)
  5. Moffet H, "Effectiveness of intensive rehabilitation on functional ability and quality of life after first total knee arthroplasty : a singleblind randomized controlled trial", Archives of physical medicine and rehabilitation, 85(4), pp.546~564 (2004)
  6. Anouchi YS, "Range of motion in total knee replacement", Clinical Orthopaedics and Related Research, 331, pp.87~92 (1996)
  7. Chester VL, "Gait analysis", Biomedical instrumentation & technology, 39(1), pp.64~74 (2005)
  8. Bamberg SJM, "Gait analysis using a shoe-integrated wireless sensor system", IEEE Transactions on Information Technology in Biomedicine, 12(4), pp.413~423 (2008)
  9. LeMoyne R, "Wireless MEMS Networks and Applications", pp.129~152 (2017), Elsevier
  10. Seel T, "IMU-based joint angle measurement for gait analysis", Sensors, 14(4), pp.6891~6909 (2014)
  11. Morris J, "Accelerometry—A technique for the measurement of human body movements", Journal of biomechanics, 6(6), pp.729~736 (1973)
  12. Currie G, "Measurement of gait by accelerometer and walkway : a comparison study", Medical & biological engineering & computing, 30(6), pp.669~670 (1992)
  13. Auvinet B, "Reference data for normal subjects obtained with an accelerometric device", Gait & posture, 16(2), pp.124~134 (2002)
  14. Tong K, "A practical gait analysis system using gyroscopes", Medical engineering & physics, 21(2), pp.87~94 (1999)
  15. Weber DJ, "BIONic WalkAide for correcting foot drop", IEEE Transactions on neural systems and rehabilitation engineering, 13(2), pp.242~246 (2005)
  16. 박선우, "보행주기 검출용 모션 센서 시스템의 비교", 한국정밀공학회지, 27(2), pp.145~152 (2010), 한국정밀공학회
  17. Thomas S, "IMU-Based Joint Angle Measurement for Gait Analysis", Sensors, 14, pp.6891~6909 (2014)
  18. Allseits EK, "Characterizing the impact of sampling rate and filter design on the morphology of lower limb angular velocities", IEEE Sensors Journal, 19(11), pp.4115~4122 (2019)

관련 논문AI추천

이 간행물의 다른 논문 (2건)