모션 캡처 시스템에 대한 고찰: 임상적 활용 및 운동형상학적 변인 측정 중심으로
A Review of Motion Capture Systems: Focusing on Clinical Applications and Kinematic Variables
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
To solve the pathological problems of the musculoskeletal system based on evidence, a so-phisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical marker-less tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze mo-tions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advan-tage that human motion analysis is no longer limited to laboratories.
Abstract
To solve the pathological problems of the musculoskeletal system based on evidence, a so-phisticated analysis of human motion is required. Traditional optical motion capture systems with high validity and reliability have been utilized in clinical practice for a long time. However, expensive equipment and professional technicians are required to construct optical motion capture systems, hence they are used at a limited capacity in clinical settings despite their advantages. The development of information technology has overcome the existing limit and paved the way for constructing a motion capture system that can be operated at a low cost. Recently, with the development of computer vision-based technology and optical marker-less tracking technology, webcam-based 3D human motion analysis has become possible, in which the intuitive interface increases the user-friendliness to non-specialists. In addition, unlike conventional optical motion capture, with this approach, it is possible to analyze mo-tions of multiple people at simultaneously. In a non-optical motion capture system, an inertial measurement unit is typically used, which is not significantly different from a conventional optical motion capture system in terms of its validity and reliability. With the development of markerless technology and advent of non-optical motion capture systems, it is a great advan-tage that human motion analysis is no longer limited to laboratories.
참고문헌 (46)
- Weber W, "Mechanik der menschlichen gehwerkzeuge:eine anatomisch-physiologische untersuchung" (1836), Dieterich
- Marey EJ, "Animal mechanism: a treatise on terrestrial and aerial locomotion" (1874), Henry S. King & Company
- Muybridge E, "Animal locomotion" (1887), Da Capo Press
- Lamine H, "Evaluation of calibrated kinect gait kinematics using a vicon motion capture system", Comput Methods Biomech Biomed Engin, 20(Suppl 1), pp.111~112 (2017)
- Albert JA, "Evaluation of the pose tracking performance of the azure kinect and kinect v2 for gait analysis in comparison with a gold standard: a pilot study", Sensors(Basel), 20(18), pp.5104~ (2020)
- Regazzoni D, "RGB cams vs RGB-D sensors : low cost motion capture technologies performances and limitations", J Manuf Syst, 33(4), pp.719~728 (2014)
- Erika D'Antonio, "A markerless system for gait analysis based on OpenPose library", 2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), pp.1~6 (2020), IEEE
- D’Antonio E, "Validation of a 3D markerless system for gait analysis based on OpenPose and two RGB webcams", IEEE Sens J, 21(15), pp.17064~17075 (2021)
- Barker S, "Accuracy, reliability, and validity of a spatiotemporal gait analysis system", Med Eng Phys, 28(5), pp.460~467 (2006)
- Lu Z, "Measurement properties of a 2-dimensional movement analysis system : a systematic review and meta-analysis", Arch Phys Med Rehabil, 101(9), pp.1603~1627 (2020)
- Baker NA, "Kinematics of the fingers and hands during computer keyboard use", Clin Biomech(Bristol, Avon), 22(1), pp.34~43 (2007)
- Reznick E, "Lower-limb kinematics and kinetics during continuously varying human locomotion", Sci Data, 8(1), pp.282~ (2021)
- Wang S, "Biomechanical analysis of the human knee joint", J Healthc Eng, 2022, pp.9365362~ (2022)
- Younes G, "Pose tracking for augmented reality applications in outdoor archaeological sites", J Electron Imaging, 26(1), pp.011004~ (2016)
- Weiss PL, "Video capture virtual reality as a flexible and effective rehabilitation tool", J Neuroeng Rehabil, 1(1), pp.12~ (2004)
- 황지선, "정면과 측면에 위치시킨 마이크로 소프트 키넥트 2로 측정한 보행 시공간 변인 정확성 비교", 한국전문물리치료학회지, 26(1), pp.1~7 (2019), 한국전문물리치료학회[DOI]
- Ota M, "Verification of reliability and validity of motion analysis systems during bilateral squat using human pose tracking algorithm", Gait Posture, 80, pp.62~67 (2020)
- Cai L, "Validity and reliability of upper limb functional assessment using the Microsoft Kinect V2Sensor", Appl Bionics Biomech, 2019, pp.7175240~ (2019)
- Choppin S, "The potential of the Microsoft Kinect in sports analysis and biomechanics", Sports Technol, 6(2), pp.78~85 (2013)
- Pfister A, "Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis", J Med Eng Technol, 38(5), pp.274~280 (2014)
- Gabel M, "Full body gait analysis with Kinect", Annu Int Conf IEEE Eng Med Biol Soc, 2012, pp.1964~1967 (2012)
- Tanaka R, "Validity of time series kinematical data as measured by a markerless motion capture system on a flatland for gait assessment", J Biomech, 71, pp.281~285 (2018)
- Mentiplay BF, "Gait assessment using the Microsoft Xbox One Kinect : concurrent validity and inter-day reliability of spatiotemporal and kinematic variables", J Biomech, 48(10), pp.2166~2170 (2015)
- Schlagenhauf F, "Comparison of Kinect and Vicon motion capture of upper-body joint angle tracking", Paper presented at : 2018 IEEE 14th International Conference on Control and Automation(ICCA), pp.674~679 (2018), IEEE
- Tipton CC, "The use of Microsoft Kinect™ for assessing readiness of return to sport and injury risk exercises : a validation study", Int J Sports Phys Ther, 14(5), pp.724~730 (2019)
- Sun K, "Deep high-resolution representation learning for human pose estimation", 2019 IEEE, 2019, 5686~5696[DOI]
- Cao Z, "Realtime multi-person 2D pose estimation using part affinity fields", 2017 IEEE Conference on Computer Vision and Pattern Recognition(CVPR), pp.1302~1310 (2017), IEEE
- Badave H, "Evaluation of person recognition accuracy based on OpenPose parameters", 2021 5th International Conference on Intelligent Computing and Control Systems(ICICCS), pp.635~640 (2021), IEEE
- Raaj Y, "Efficient online multiperson 2D pose tracking with recurrent spatio-temporal affinity fields", 2019 IEEE, 2019, 5686~5696[DOI]
- Pusara A, "Reliability of a low-cost webcam recording system for threedimensional lower limb gait analysis", Int Biomech, 6(1), pp.85~92 (2019)
- Bashinskaya B, "Effects of obesity on walking patterns and adaptability during obstacle crossing", doctor, pp.2011
- Williamson J, "Data sensing and analysis : challenges for wearables", The 20th Asia and South Pacific Design Automation Conference, pp.136~141 (2015), IEEE
- Zhu S, "Advances in multimedia information processing", pp.105~116 (2012), Springer
- Prasanth H, "Wearable sensor-based real-time gait detection: a systematic review", Sensors(Basel), 21(8), pp.2727~ (2021)
- 조영신, "Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems", Annals of Rehabilitation Medicine, 42(6), pp.872~883 (2018), 대한재활의학회
- Zhong Z, "A realtime pre-impact fall detection and protection system", 2018 IEEE, 2018, 1039~1044[DOI]
- Ahn S, "Optimization of a pre-impact fall detection algorithm and development of hip protection airbag system", Sens Mater, 30(8), pp.1743~1752 (2018)
- Oh D, "Concurrent validity and intra-trial reliability of a Bluetooth-embedded inertial measurement unit for real-time joint range of motion", Int J Comput Sci Sport, 18(3), pp.1~11 (2019)
- Zhu R, "A real-time articulated human motion tracking using tri-axis inertial", magnetic sensors package, 2004, pp.12(2), 295~302
- Wei W, "Real-time 3D arm motion tracking using the 6-axis IMU sensor of a smartwatch", 2021 IEEE 17th International Conference on Wearable and Implantable Body Sensor Networks (BSN), pp.1~4 (2021), IEEE
- Raab FH, "Magnetic position and orientation tracking system", IEEE Trans Aerosp Electron Syst, 5, pp.709~718 (1979)
- Hashi S, "Wireless magnetic motion capture system for multi-marker detection", IEEE Trans Magn, 42(10), pp.3279~3281 (2006)
- Kanetaka H, "Interface oral health science", pp.329~331 (2009), Springer
- Roetenberg D, "Estimating body segment orientation by applying inertial and magnetic sensing near ferromagnetic materials", IEEE Trans Neural Syst Rehabil Eng, 15(3), pp.469~471 (2007)
- Tinghao Wu, "Application and validation of a mechanical motion capture-based industrial ergonomics system", SAE Technical Paper Series (2005), SAE International
- Rahul M, "Review on motion capture technology", Glob J Comput Sci Technol, 18(1), pp.23~26 (2018)
