본문 바로가기
KERD
논문KCI 등재

Comparison of Cable Method and Miniaci Method Using Picture Archiving and Communication System in Preoperative Planning for Open Wedge High Tibial Osteotomy

1

조회

0

다운로드

6

인용

0

참고문헌

키워드

초록

purpose: The purpose was to compare the accuracy of Miniaci method using picture archiving and communication system (PACS) with a cable method in high tibial osteotomy (HTO).Materials and Methods: This study analyzed 47 patients (52 knees) with varus deformity and medial osteoarthritis. From 2007 to 2013, patients underwent HTO using either a cable method (20 knees) or Miniaci method based on a PACS image (32 knees). In the cable method, the 62.5% point of the mediolateral tibial plateau width was located using an electrocautery cord under fluoroscopy (cable group). The Miniaci method used preoperative radiographs to shift the weight bearing axis (PACS group). Full-length lower limb radiographs obtained preoperatively and at the sixth postoperative week were used to compare the percentage of crossing point of the weight bearing line on the tibial plateau with respect to the medial border.results: The weight bearing line on the tibial plateau was corrected from a preoperative 11.0±7.0% to a postoperative 47.2±7.4% in the cable group and from 12.7±4.9% to 59.5±5.3% in the PACS group. The mechanical femorotibial angle was corrected from varus 8.9±3.7° to valgus 0.3±4.0° in the cable group and from varus 9.0±3.3° to valgus 2.9±2.6° in the PACS group.conclusions: In HTO, correction based on the Miniaci method using a PACS was more accurate than correction using the cable method.

Abstract

purpose: The purpose was to compare the accuracy of Miniaci method using picture archiving and communication system (PACS) with a cable method in high tibial osteotomy (HTO).Materials and Methods: This study analyzed 47 patients (52 knees) with varus deformity and medial osteoarthritis. From 2007 to 2013, patients underwent HTO using either a cable method (20 knees) or Miniaci method based on a PACS image (32 knees). In the cable method, the 62.5% point of the mediolateral tibial plateau width was located using an electrocautery cord under fluoroscopy (cable group). The Miniaci method used preoperative radiographs to shift the weight bearing axis (PACS group). Full-length lower limb radiographs obtained preoperatively and at the sixth postoperative week were used to compare the percentage of crossing point of the weight bearing line on the tibial plateau with respect to the medial border.results: The weight bearing line on the tibial plateau was corrected from a preoperative 11.0±7.0% to a postoperative 47.2±7.4% in the cable group and from 12.7±4.9% to 59.5±5.3% in the PACS group. The mechanical femorotibial angle was corrected from varus 8.9±3.7° to valgus 0.3±4.0° in the cable group and from varus 9.0±3.3° to valgus 2.9±2.6° in the PACS group.conclusions: In HTO, correction based on the Miniaci method using a PACS was more accurate than correction using the cable method.

참고문헌 (26)

  1. Amendola A, "Results of high tibial osteotomy : review of the literature", Int Orthop, 34, pp.155~160 (2010)
  2. Ozalay M, "The correlation of correction magnitude and tibial slope changes following open wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 16, pp.948~951 (2008)
  3. Song EK, "The complications of high tibial osteotomy : closing-versus opening-wedge methods", J Bone Joint Surg Br, 92, pp.1245~1252 (2010)
  4. Sprenger TR, "Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years", J Bone Joint Surg Am, 85, pp.469~474 (2003)
  5. Engel GM, "Valgus tibial osteotomy: avoiding the pitfalls", Clin Orthop Relat Res, (160), pp.137~143 (1981)
  6. Kettelkamp DB, "Results of proximal tibial osteotomy. The effects of tibiofemoral angle, stance-phase flexion-extension, and medial-plateau force", J Bone Joint Surg Am, 58, pp.952~960 (1976)
  7. Tjornstrand B, "Roentgen stereophotogrammetry in high tibial osteotomy for gonarthrosis", Arch Orthop Trauma Surg, 99, pp.73~81 (1981)
  8. Marx RG, "Reliability of lower extremity alignment measurement using radiographs and PACS", Knee Surg Sports Traumatol Arthrosc, 19, pp.1693~1698 (2011)
  9. Heijens E, "The role of navigation in high tibial osteotomy: a study of 50 patients", Orthopedics, 32(10 Suppl), pp.40~43 (2009)
  10. Schroter S, "Digital planning of high tibial osteotomy : interrater reliability by using two different software", Knee Surg Sports Traumatol Arthrosc, 21, pp.189~196 (2013)
  11. Fujisawa Y, "The effect of high tibial osteotomy on osteoarthritis of the knee : an arthroscopic study of 54 knee joints", Orthop Clin North Am, 10, pp.585~608 (1979)
  12. Miniaci A, "Proximal tibial osteotomy: a new fixation device", Clin Orthop Relat Res, (246), pp.250~259 (1989)
  13. Marti CB, "Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy", Arthroscopy, 20, pp.366~372 (2004)
  14. Hernigou P, "Proximal tibial osteotomy for osteoarthritis with varus deformity : a ten to thirteen-year follow-up study", J Bone Joint Surg Am, 69, pp.332~354 (1987)
  15. El-Azab HM, "Limb alignment after open-wedge high tibial osteotomy and its effect on the clinical outcome", Orthopedics, 34, pp.e622~e628 (2011)
  16. Marti RK, "Proximal tibial varus osteotomy. Indications, technique, and five to twenty-one-year results", J Bone Joint Surg Am, 83, pp.164~170 (2001)
  17. Coventry MB, "Upper tibial osteotomy for osteoarthritis", J Bone Joint Surg Am, 67, pp.1136~1140 (1985)
  18. Dugdale TW, "Preoperative planning for high tibial osteotomy: the effect of lateral tibiofemoral separation and tibiofemoral length", Clin Orthop Relat Res, (274), pp.248~264 (1992)
  19. Pape D, "Imaging and preoperative planning of osteotomy of tibial head osteotomy", Orthopade, 33, pp.122~134 (2004)
  20. Blakeney WG, "Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty : a randomized controlled trial", J Bone Joint Surg Am, 93, pp.1377~1384 (2011)
  21. Goleski P, "Reliability of navigated lower limb alignment in high tibial osteotomies", Am J Sports Med, 36, pp.2179~2186 (2008)
  22. Hankemeier S, "Navigated open-wedge high tibial osteotomy : advantages and disadvantages compared to the conventional technique in a cadaver study", Knee Surg Sports Traumatol Arthrosc, 14, pp.917~921 (2006)
  23. Hankemeier S, "Navigated intraoperative analysis of lower limb alignment", Arch Orthop Trauma Surg, 125, pp.531~535 (2005)
  24. Kyung BS, "Are navigation systems accurate enough to predict the correction angle during high tibial osteotomy? Comparison of navigation systems with 3-dimensional computed tomography and standing radiographs", Am J Sports Med, 41, pp.2368~2374 (2013)
  25. Sabharwal S, "Assessment of lower limb alignment : supine fluoroscopy compared with a standing full-length radiograph", J Bone Joint Surg Am, 90, pp.43~51 (2008)
  26. Lee YS, "Comparative analysis of osteotomy accuracy between the conventional and devised technique using a protective cutting system in medial open-wedge high tibial osteotomy", J Orthop Sci, 20, pp.129~136 (2015)

관련 논문AI추천

Comparison of Mechanical Axis and Dynamic Range Assessed with Weight Bearing Radiographs and Navigation System in Closed Wedge High Tibial Osteotomy배대경, 송상준, 이종환, 조성진대한슬관절학회 · Knee Surgery and Related Research2017 · 제29권 제3호Disparity between Preoperative Target Correction Amount and Postoperative Correction Amount in Open Wedge High Tibial Osteotomy이용석, Eui Soo Lee, O-­Sung Lee대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제2호The influence of computer-assisted surgery experience on the accuracy and precision of the postoperative mechanical axis during computer-assisted lateral closingwedge high tibial osteotomyCheol Hee Park, Dae Kyung Bae, Hyun Woo Lee, Sang Jun Song대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제1호Analysis of radiographic factors affecting the significant differences in knee alignment between hip-to-talus and hip-to-calcaneus radiographs after opening-wedge high tibial osteotomyDong Hun Suh, Hyung Jun Park, Jae Gyoon Kim, Joon Hyeok Boo대한슬관절학회 · Knee Surgery and Related Research2023 · 제35권 Navigated versus Conventional Technique in High Tibial Osteotomy: A Meta­Analysis Focusing on Weight Bearing Effect심재앙, Hyuk Min Kwon, Kyung Wook Nha, Young Gon Na, Young­Soo Shin대한슬관절학회 · Knee Surgery and Related Research2019 · 제31권 제2호Radiologic simulation of leg length change after double level osteotomy in preoperative surgical planningKen Kumagai, Masaichi Sotozawa, Shunsuke Yamada, Shuntaro Nejima, Yutaka Inaba대한슬관절학회 · Knee Surgery and Related Research2023 · 제35권

이 간행물의 다른 논문 (12건)