Purpose: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. Materials and Methods: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. Results: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. Conclusion: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.

Abstract

Purpose: To compare preoperative and postoperative ocular biometry in patients with iris-fixated phakic intraocular lens (pIOLs): Artisan and Artiflex. Materials and Methods: This study included 40 eyes with Artisan and 36 eyes with Artiflex pIOL implants. Anterior chamber depth (ACD) and axial length (AL) were measured by applanation ultrasonography (A-scan) and partial coherence interferometry (IOLMaster) preoperatively and 3 months after pIOL implantation. Results: ACD measurements after Artisan or Artiflex pIOL implantation were smaller than preoperative measurements. Specifically, the difference after Artisan pIOL implantation was -1.07±0.17 mm by A-scan and -0.08±0.08 mm by IOLMaster. The difference after Artiflex pIOL implantation was -1.31±0.15 mm by A-scan and -0.05±0.07 mm by IOLMaster. After Artisan pIOL implantation, differences in AL measurements by A-scan were insignificant (difference: -0.03±0.15 mm), whereas postoperative AL measurements by IOLMaster were significantly longer than preoperative measurements (difference: 0.12±0.07 mm). After Artiflex pIOL implantation, AL measurements by both A-scan and IOLMaster were significantly longer than preoperative measurements (difference: 0.09±0.16 mm by A-scan and 0.07±0.10 mm by IOLMaster). In the Artiflex group, differences in AL measurements by A-scan correlated with the central thickness of the Artiflex pIOL. Conclusion: ACD and AL measurements were influenced by iris-fixated phakic IOL implantation.

참고문헌 (21)

  1. Huang D, "Phakic intraocular lens implantation for the correction of myopia: a report by the American Academy of Ophthalmology", Ophthalmology, 116, pp.2244~2258 (2009)
  2. Stulting RD, "Three-year results of Artisan", Verisyse phakic intraocular lens implantation. Results of the United States Food And Drug Administration clinical trial, 2008, pp.115, 464~472
  3. Dick HB, "Foldable Artiflex phakic intraocular lens for the correction of myopia: two-year follow-up results of a prospective European multicenter study", Ophthalmology, 116, pp.671~677 (2009)
  4. Saxena R, "Long-term follow-up of endothelial cell change after Artisan phakic intraocular lens implantation", Ophthalmology, 115, pp.608~613 (2008)
  5. Georgalas I, "Bilateral giant tear-associated retinal detachment following Artisan phakic intraocular lens implantation for correction of moderate myopia", Acta Ophthalmol, 88, pp.e143~e144 (2010)
  6. Lee SJ, "Traumatic aniridia and aphakia after Artisan intraocular lens implantation", J Cataract Refract Surg, 33, pp.1341~1342 (2007)
  7. Chen LJ, "Metaanalysis of cataract development after phakic intraocular lens surgery", J Cataract Refract Surg, 34, pp.1181~1200 (2008)
  8. Moshirfar M, "Cataract surgery following phakic intraocular lens implantation", Curr Opin Ophthalmol, 21, pp.39~44 (2010)
  9. Kohnen T, "Phakic intraocular lenses: part 2: results and complications", J Cataract Refract Surg, 36, pp.2168~2194 (2010)
  10. Hoffer KJ, "Ultrasound axial length measurement in biphakic eyes", J Cataract Refract Surg, 29, pp.961~965 (2003)
  11. Sanders DR, "The Visian myopic implantable collamer lens does not significantly affect axial length measurement with the IOLMaster", J Refract Surg, 24, pp.957~959 (2008)
  12. Khokhar SK, "Comparison of preoperative and postoperative axial length measurement with immersion A-scan in ICL cases", J Cataract Refract Surg, 35, pp.2168~2169 (2009)
  13. Pitault G, "Optical biometry of eyes corrected by phakic intraocular lenses", J Fr Ophtalmol, 28, pp.1052~1057 (2005)
  14. de Vries NE, "Results of cataract surgery after implantation of an iris-fixated phakic intraocular lens", J Cataract Refract Surg, 35, pp.121~126 (2009)
  15. Vetrugno M, "Anterior chamber depth measured by two methods in myopic and hyperopic phakic IOL implant", Br J Ophthalmol, 84, pp.1113~1116 (2000)
  16. Sheng H, "Ocular component measurement using the Zeiss IOLMaster", Optom Vis Sci, 81, pp.27~34 (2004)
  17. Holladay JT, "Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations", J Cataract Refract Surg, 23, pp.1356~1370 (1997)
  18. 홍진표, "Reliability of RTVue, Visante, and Slit-Lamp Adapted Ultrasonic Pachymetry for Central Corneal Thickness Measurement", Yonsei Medical Journal, 53(3), pp.634~641 (2012), 연세대학교의과대학[DOI]
  19. Eleftheriadis H, "IOLMaster biometry: refractive results of 100 consecutive cases", Br J Ophthalmol, 87, pp.960~963 (2003)
  20. Rose LT, "Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calculation", Clin Experiment Ophthalmol, 31, pp.121~124 (2003)
  21. Parravano M, "Reliability of the IOLMaster in axial length evaluation in silicone oil-filled eyes", Eye, 21, pp.909~911 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (15건)