Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 500, IOL Master 700, and Lenstar LS900

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류안과학

초록

Purpose: To evaluate the agreement in ocular biometry outcomes measured by three different devices, the IOLMaster 500, IOL Master 700, and Lenstar LS900, and compare the refractive outcomes after cataract surgeryobtained using those three devices. Methods: Medical records of 178 eyes of 89 patients who underwent ocular biometry with the three deviceswere retrospectively reviewed, and 124 eyes met the inclusion criteria. Paired comparisons were performedfor axial length (AL), mean keratometry (Km), and anterior chamber depth and quantified their agreement usingBland-Altman plots. Subgroup analyses were done according to the AL and the Km. Refractive outcomeswere compared with respect to absolute prediction errors after cataract surgery in 54 eyes. Results: Among 124 eyes, 12, 3, and 5 eyes failed to be measured of AL by IOL Master 500, IOL Master 700and Lenstar LS900, respectively. The AL measured by Lenstar LS900 was longer than that measured by IOLMaster 500 and IOL Master 700 (p < 0.001, p = 0.002, respectively). Subgroup analysis revealed that theseresults were statistically significant only in long eyes (AL >25.5 mm). Km measured using the IOL Master 500was steeper than that measured with the IOL Master 700 or Lenstar LS900 (p = 0.001, p < 0.001, respectively). anterior chamber depth measured by IOL Master 500 was shallower than that measured by IOL Master700 or Lenstar LS900 (p < 0.001, p < 0.001, respectively). Ocular biometry measurements by the three devicesshowed high agreement with narrow 95% limits of agreement. Absolute prediction errors from the 3 devicesshowed no statistically significant differences after cataract surgery. Conclusions: The IOL Master 700 and Lenstar LS900 demonstrated superior acquisition rates of biometricmeasurements compared with the IOL Master 500. Ocular biometry using the 3 different devices showed highagreement, although statistically significant differences were observed; however, since there was no differencein predicting the refractive outcomes, those differences are clinically negligible.

Abstract

Purpose: To evaluate the agreement in ocular biometry outcomes measured by three different devices, the IOLMaster 500, IOL Master 700, and Lenstar LS900, and compare the refractive outcomes after cataract surgeryobtained using those three devices. Methods: Medical records of 178 eyes of 89 patients who underwent ocular biometry with the three deviceswere retrospectively reviewed, and 124 eyes met the inclusion criteria. Paired comparisons were performedfor axial length (AL), mean keratometry (Km), and anterior chamber depth and quantified their agreement usingBland-Altman plots. Subgroup analyses were done according to the AL and the Km. Refractive outcomeswere compared with respect to absolute prediction errors after cataract surgery in 54 eyes. Results: Among 124 eyes, 12, 3, and 5 eyes failed to be measured of AL by IOL Master 500, IOL Master 700and Lenstar LS900, respectively. The AL measured by Lenstar LS900 was longer than that measured by IOLMaster 500 and IOL Master 700 (p < 0.001, p = 0.002, respectively). Subgroup analysis revealed that theseresults were statistically significant only in long eyes (AL >25.5 mm). Km measured using the IOL Master 500was steeper than that measured with the IOL Master 700 or Lenstar LS900 (p = 0.001, p < 0.001, respectively). anterior chamber depth measured by IOL Master 500 was shallower than that measured by IOL Master700 or Lenstar LS900 (p < 0.001, p < 0.001, respectively). Ocular biometry measurements by the three devicesshowed high agreement with narrow 95% limits of agreement. Absolute prediction errors from the 3 devicesshowed no statistically significant differences after cataract surgery. Conclusions: The IOL Master 700 and Lenstar LS900 demonstrated superior acquisition rates of biometricmeasurements compared with the IOL Master 500. Ocular biometry using the 3 different devices showed highagreement, although statistically significant differences were observed; however, since there was no differencein predicting the refractive outcomes, those differences are clinically negligible.

참고문헌 (19)

  1. Fontes BM, "Intraocular lens power calculation by measuring axial length with partial optical coherence and ultrasonic biometry", Arq Bras Oftalmol, 74, pp.166~170 (2011)
  2. Shammas HJ, "Precision of biometry, keratometry, and refractive measurements with a partial coherence interferometry-keratometry device", J Cataract Refract Surg, 36, pp.1474~1478 (2010)
  3. Vogel A, "Reproducibility of optical biometry using partial coherence interferometry : intraobserver and interobserver reliability", J Cataract Refract Surg, 27, pp.1961~1968 (2001)
  4. Akman A, "Evaluation and comparison of the new swept source OCT-based IOLMaster 700with the IOLMaster 500", Br J Ophthalmol, 100, pp.1201~1205 (2016)
  5. Cruysberg LP, "Evaluation of the Lenstar LS 900 non-contact biometer", Br J Ophthalmol, 94, pp.106~110 (2010)
  6. Olsen T, "Calculation of intraocular lens power : a review", Acta Ophthalmol Scand, 85, pp.472~485 (2007)
  7. Chylack LT Jr, "The lens opacities classification system III. The longitudinal study of cataract study group", Arch Ophthalmol, 111, pp.831~836 (1993)
  8. Hirnschall N, "Enhanced penetration for axial length measurement of eyes with dense cataracts using swept source optical coherence tomography : a consecutive observational study", Ophthalmol Ther, 7, pp.119~124 (2018)
  9. Buckhurst PJ, "A new optical low coherence reflectometry device for ocular biometry in cataract patients", Br J Ophthalmol, 93, pp.949~953 (2009)
  10. McAlinden C, "Axial length measurement failure rates with the IOLMaster and Lenstar LS 900 in eyes with cataract", PLoS One, 10, pp.e0128929~ (2015)
  11. Arriola-Villalobos P, "Agreement and clinical comparison between a new sweptsource optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer", Eye(Lond), 31, pp.437~442 (2017)
  12. Hoffer KJ, "Comparison of 2 laser instruments for measuring axial length", J Cataract Refract Surg, 36, pp.644~648 (2010)
  13. Holzer MP, "Accuracy of a new partial coherence interferometry analyser for biometric measurements", Br J Ophthalmol, 93, pp.807~810 (2009)
  14. Rohrer K, "Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer", Ophthalmology, 116, pp.2087~2092 (2009)
  15. Olsen T, "Sources of error in intraocular lens power calculation", J Cataract Refract Surg, 18, pp.125~129 (1992)
  16. Santodomingo-Rubido J, "A new non-contact optical device for ocular biometry", Br J Ophthalmol, 86, pp.458~462 (2002)
  17. Epitropoulos A, "Axial length measurement acquisition rates of two optical biometers in cataractous eyes", Clin Ophthalmol, 8, pp.1369~1376 (2014)
  18. Hoffer KJ, "Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry", J Cataract Refract Surg, 42, pp.1165~1172 (2016)
  19. Srivannaboon S, "Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer", J Cataract Refract Surg, 41, pp.2224~2232 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (13건)