This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42cm, 37cm, and 31cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.
Abstract
This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42cm, 37cm, and 31cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.
참고문헌 (15)
- Lee CH, "Electrophysiology study & radiofrequency catheter ablation", Journal of Korean Society of Cardio-Vascular Interventional Technology, 8(1), pp.45~52 (2005)[DOI]
- 온영근, "빈맥성 부정맥의 전극도자절제술", 대한내과학회지, 90(3), pp.206~209 (2016), 대한내과학회
- 서영현, "냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성", 한국방사선학회논문지, 16(4), pp.427~434 (2022), 한국방사선학회[DOI]
- Cho HO, "Radiation dose and cancer risk of cardiac electrophysiology procedures", International Journal of Arrhythmia, 16(1), pp.4~10 (2015)[DOI]
- Prames K, "Risk to patients from radiation associated with radiofrequency ablation for SVT", Circulation, 98(15), pp.1534~1540 (1998)[DOI]
- Marini M, "The benefit of a general, systematic use of mapping systems during electrophysiological procedures in children and teenagers : The experience of an adult EP laboratory", Pediatric Cardiology, 37(4), pp.802~809 (2016)[DOI]
- Kim YN, "Significance of cardiac electrophysiological testing in the diagnosis and treatment of arrhythmias", Keimyung Medical Journal, 11(3), pp.337~344 (1992)[DOI]
- Park TH, "Risk of radiation induced skin injuries from arrhythmia ablation procedures", Pacing and Clinical Electrophysiology : PACE, 19(9), pp.1363~1369 (1996)[DOI]
- 강영한, "디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소", 한국방사선학회논문지, 7(4), pp.277~284 (2013), 한국방사선학회[DOI]
- Jung HY, "A study on the reduction of radiation dose in pediatric chest CT examinations using advanced model-based iterative reconstruction", master, pp.2022
- Kim JM, "A study on the dose characteristics of Optically Stimulated Luminescent Dosimeters(OSLD)", Journal of the Korean Society for Radiation Therapy, 22(2), pp.123~129 (2010)[DOI]
- Kim JR, "A new concept and principle of Optically Stimulated Luminescence Dosimetry(OSLD)", Journal of the Korean Society of Isotope, 18(4), pp.75~80 (2003)[DOI]
- 김원효, "심장 혈관 조영장치에서의 프레임 레이트(f", s) 변화에 따른 상관관계 분석 : FOV 확대와 Live Zoom을 중점으로, 2018, pp.12(7), 845~852[DOI]
- 박찬우, "두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안", 한국방사선학회논문지, 13(3), pp.399~406 (2019), 한국방사선학회[DOI]
- Thibault B, "Reducing radiation exposure during procedures performed in the electrophysiology laboratory", Journal of Cardiovascular Electrophysiology, 29(2), pp.308~315 (2018)[DOI]