본문 바로가기
KERD
논문KCI 등재

초급성 허혈성 뇌졸중 환자에서 3.0T 유속증강 자기공명 혈관 조영술을 이용한 임상적 유용성 고찰:1.5T 기준참고 프로토콜

A Clinical Usefulness Study on 3.0T Flow-Related Enhancement Magnetic Resonance Angiography in Hyper-Acute Stroke Patient: 1.5T Standard Reference Protocol

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The purpose of this study was to provide information on the quality of the imagesof the fast 3D TOF MRA by analyzing retrospective the Flow-Related Enhancement MagneticResonance Angiography need to check for Hyper-Acute Stroke according to parameters using the1.5T Standard Reference. The study randomly chose transferred data to PACS (Picture ArchivingCommunication System) targeted 30 patients who perform MRA and Hyper-Acute Stroke MRIexamination at C university hospital from February 2018 to January 2019. For quantitativeevaluation,we measured SNR, CNR to measure average value and standard deviation of signalintensity after setting constant area of interest about cerebral vascular 7 parts according to 3technique (1.5T SRP, 1.5T HAS, 3.0T HAS)protocol. Measurement result is high or in comparison1.5T SRP with 3.0T HAS, it showed 3.0T HAS more higher or same result. Consequently, theanalysis of 7 parts showed that the values of SNR and CNR were 3.0T HAS≥1.5T SRP>1.5THAS. Therefore, the 3.0T fast 3D TOF MRA technique showed significant results in the qualityevaluation of the images.

Abstract

The purpose of this study was to provide information on the quality of the imagesof the fast 3D TOF MRA by analyzing retrospective the Flow-Related Enhancement MagneticResonance Angiography need to check for Hyper-Acute Stroke according to parameters using the1.5T Standard Reference. The study randomly chose transferred data to PACS (Picture ArchivingCommunication System) targeted 30 patients who perform MRA and Hyper-Acute Stroke MRIexamination at C university hospital from February 2018 to January 2019. For quantitativeevaluation,we measured SNR, CNR to measure average value and standard deviation of signalintensity after setting constant area of interest about cerebral vascular 7 parts according to 3technique (1.5T SRP, 1.5T HAS, 3.0T HAS)protocol. Measurement result is high or in comparison1.5T SRP with 3.0T HAS, it showed 3.0T HAS more higher or same result. Consequently, theanalysis of 7 parts showed that the values of SNR and CNR were 3.0T HAS≥1.5T SRP>1.5THAS. Therefore, the 3.0T fast 3D TOF MRA technique showed significant results in the qualityevaluation of the images.

참고문헌 (17)

  1. Abuzinadah AR, "Stroke recurrence rates among patients with symptomatic intracranial vertebrobasilar stenoses : systematic review and meta-analysis", J. Neurointerv. Surg, 8(2), pp.112~116 (2016)
  2. Choi JW, "Optimization of MR Parameters of 3D TOF-MRA for Various Intracranial Stents at 3. 0T MRI", Neurointervention, 6(2), pp.71~77 (2011)
  3. Dancer S, "National Institutes of Health Stroke Scale in Plain English Is Reliable for Novice Nurse Users With Minimal Training", J. Emerg. Nurs, 43(3), pp.221~227 (2017)
  4. Goo EH, "The Evaluation of Image Quality using Time of Flight in Intracranial Magnetic Resonance Imaging : Comparison with 1.5T and 3.0T", Korean J. Digit. Imag. Med., 7(1), pp.43~48 (2015)
  5. 한용수, "3D-SPACE T2 기법에 의한 TOF-MRA검사 시 발생하는 혈관 내 협착 정도의 측정 오류 개선에 관한 연구", 전자공학회논문지, 51(12), pp.180~188 (2014), 대한전자공학회
  6. Hiai Y, "3D TOF MRA of intracranial aneurysms at 1.5 T and 3 T: influence of matrix, parallel imaging, and acquisition time on image quality - a vascular phantom study", Acad. Radiol., 15(5), pp.635~640 (2008)
  7. Hodel J, "Comparison of 3D multiecho gradient-echo and 2D T2* MR sequences for the detection of arterial thrombus in patients with acute stroke", Eur. Radiol, 24(3), pp.762~769 (2014)
  8. Kuo WT, "Catheter-directed therapy for the treatment of massive pulmonary embolism : systematic review and meta-analysis of modern techniques", J. Vasc. Interv. Radiol, 20(11), pp.1431~1440 (2009)
  9. Heui Seung Lee, "Dominance of the Anterior Cerebral Artery as a Predictor of Vasospasm-Related Cerebral Infarction After Surgical Treatment of Ruptured Blood Blister-Like Aneurysm in the Internal Carotid Artery", World Neurosurgery, 130, pp.e513~e524 (2019), Elsevier BV[DOI]
  10. Li C, "Outcome of endovascular treatment for acute basilar artery occlusion in the modern era : a single institution experience", Neuroradiology, 60(6), pp.651~659 (2018)
  11. Lin Z, "The applied research of MRI with ASSET-EPI-FLAIR combined with 3D TOF MRA sequences in the assessment of patients with acute cerebral infarction", Acta. Radiologica, 57(12), pp.1515~1523 (2016)
  12. Nakane T, "Visualization of neuromelanin in the Substantia nigra and locus ceruleus at 1.5T using a 3D-gradient echo sequence with magnetization transfer contrast", J. Magn. Reson. Imaging, 7(4), pp.205~210 (2008)
  13. 송은경, "심혈관질환의심리사회적위험요인으로써의D유형성격에관한논문분석", Journal of Korean Academy of Nursing, 38(1), pp.19~28 (2008), 한국간호과학회
  14. Turkbey B, "Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 Tesla for localizing prostate cancer : correlation with whole-mount histopathology", J. Magn. Reson. Imaging, 39(6), pp.1443~1448 (2014)
  15. Vanikieti K, "Occipital lobe infarction : a rare presentation of bilateral giant cavernous carotid aneurysms : a case report", BMC Ophthalmol, 18(1), pp.563~572 (2018)
  16. Wacker BK, "Apolipoprotein A-I Vascular Gene Therapy Provides Durable Protection Against Atherosclerosis in Hyperlipidemic Rabbits", Arterioscler. Thromb. Vasc. Biol, 38(1), pp.206~207 (2018)
  17. Ziegler M, "Assessment of turbulent flow effects on the vessel wall using four-dimensional flow MRI", Magn. Reson. Med, 77(6), pp.2310~2319 (2017)

관련 논문AI추천

이 간행물의 다른 논문 (12건)