전산화단층촬영검사 시 검사실 내에 위치할 수 있는 의료인의 간접 피폭선량에 대한 연구
A Study on the Indirect Radiation Exposure of the Medical Personnel Who is Responsible for Patient Safety in CT Examination
1
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.
Abstract
A medical personnel could be placed beside a patient together in CT room to do Ambu-bag for a seriously ill patients or emergency patient. At this time, the medical personnel can be exposed indirect radiation unnecessarily. In this case, it is necessary to recognize indirect radiation dose levels and methods to reduce them using actual clinical CT protocols such as Chest, Abdomen, and Brain CT. We researched surface radiation dose with or without radiation protectors such as apron and goggles according to different distances far from gantry using two different CT scanners (Fixed MDCT and mobile CT). As a result, for Chest, Abdomen, and Brain CT with Fixed MDCT, indirect radiation dose on thorax portion were 0.047, 0.089, 0.034 mSv without apron. Also, those with apron were 0.007, 0.012, 0.006 mSv. In case of mobile CT, it was 0.014 mSv without apron and 0.005 mSv with apron. By using protectors and increasing the distance, we could reduce it to 97%. Systematic management is necessary based on the measured data in order to minimize radiation damage due to indirect exposure dose.
참고문헌 (17)
- Chelsea JA, "Magnetic resonance imaging and computed tomography in emergency assessment of patients with suspected acute stroke : a prospective comparison", Lancet, 369(9558), pp.293~298 (2007)
- Smith-Bindman R, "Radiation Dose Associated with Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer", Arch Intern Med, 169(22), pp.2078~2086 (2015)
- 도경현, "컴퓨터단층촬영 검사의 방사선 피폭 저감화 방안", 대한의사협회지, 58(6), pp.534~541 (2015), 대한의사협회[DOI]
- Becker CD, "The trauma concept: the role of MDCT in the diagnosis and management of visceral injuries", European Radiology, 15(Suppl. 4), pp.105~109 (2005)
- 오용해, "중등도 두부 외상에서 반복 CT 검사의 결정인자", 대한응급의학회지, 21(4), pp.444~453 (2010), 대한응급의학회
- 서선열, "중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구", 한국융합학회논문지, 8(9), pp.211~216 (2017), 한국융합학회[DOI]
- Ko IH, "Textbook of Computed Tomography" (2009), Chung-Koo
- Mettler F, "Use o f rad iology i n U.S. g eneral short-term hospital: 1980-1990", Radiology, 189(2), pp.377~380 (1993)
- McCunn M, "Physician utilization of a portable computed tomography scanner in the intensive care unit", Critical Care Medicine, 28(12), pp.3808~3813 (2000)
- Mansoor D, "Intensive Care Nurses Knowledge of Radiation safety and their behaviors towards portable radiological examinations", Nurs Midwifery Stud, 3(4), pp.e23354~ (2014)
- Guttesman BE, "Radiation exposure in emergency physicians working in an urban ED : a prospective cohort study", The American Journal of Emergency Medicine, 28(9), pp.1037~1040 (2010)
- Van Every B, "Measurements of computed tomography radiation scatter", Australas Phys Eng Sci Med, 15(1), pp.15~24 (1992)
- Ahn BS, "A study on the exposure and free space scattered dose in radiography", Journal of Korean Society of Radiological Technology, pp.26~30 (1998)
- 정홍문, "Micro-CT 촬영 시 발생되는 산란선에 관한 공간선량률 측정", 한국방사선학회논문지, 7(1), pp.45~50 (2013), 한국방사선학회[DOI]
- 박훈희, "방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰", 방사선기술과학, 41(6), pp.573~580 (2018), 대한방사선과학회[DOI]
- 김기정, "전산화단층촬영검사실 방사선사의 방사선피폭 방어행위에 영향을 미치는 요인 분석", 방사선기술과학, 41(6), pp.581~586 (2018), 대한방사선과학회[DOI]
- Nam GS, "Dose reduction of medical personnel using breathing circuit during brain CT examination with artificial manual breathing unit bagging", Journal of Korean Society of Computed Tomographic Technology, 17(2), pp.123~132 (2015)
