In the case of residential facilities, general fire scenarios cannot be applied. Becauseit is difficult to quantify due to the types of combustibles and various fire loads. Existing research conducting surveys of combustibles, but research on fire characteristics is insufficient. Therefore, in this study, an Excel macro that can be quantified by experimenting with the HRR experiments of sofa, drawer, mattress, chair, desk and TV, which are typical combustibles. As a result of experimenting 6 loading combustibles in domestic residential facilities by using a furniture calorimeter, values of 2,391.26kW appeared from the sofa, 1,891.80kW from the drawer, 1,778.95kW from the mattress, 1,104kW from the chair, 291kW from the desk, and 135.09kW from the TV. Also, by applying the α value of the fire growth rate by classifying fire-growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), the mattress can be defined as Very Fast, the sofa and drawer Fast, the TV Slow, the desk Slow, and the chair Medium.

Abstract

In the case of residential facilities, general fire scenarios cannot be applied. Becauseit is difficult to quantify due to the types of combustibles and various fire loads. Existing research conducting surveys of combustibles, but research on fire characteristics is insufficient. Therefore, in this study, an Excel macro that can be quantified by experimenting with the HRR experiments of sofa, drawer, mattress, chair, desk and TV, which are typical combustibles. As a result of experimenting 6 loading combustibles in domestic residential facilities by using a furniture calorimeter, values of 2,391.26kW appeared from the sofa, 1,891.80kW from the drawer, 1,778.95kW from the mattress, 1,104kW from the chair, 291kW from the desk, and 135.09kW from the TV. Also, by applying the α value of the fire growth rate by classifying fire-growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), the mattress can be defined as Very Fast, the sofa and drawer Fast, the TV Slow, the desk Slow, and the chair Medium.

참고문헌 (6)

  1. Kim, N.H., "Analysis of Case Studies on the Combustible Abroad to Calculate Domestic the Fire Load", Korean Institute of Fire Science & Engineering, Proceedings of 2009 Autumn Annual Conference, pp.339~345 (2009)
  2. 김동은, "공동주택의 화재성상예측을 위한 가연물 조사 및 연소특성에 관한 연구", 대한건축학회논문집, 28(03), pp.73~80 (2012), 대한건축학회
  3. Poon L., "Modeling Fire Development for Fire Engineering Design", Proceedings of 4th International Conference on Performance-Based Codes and Fire Safety Design Methods, pp.264~275 (2002)
  4. Gregory, E.G., "Fire Dynamics" (2011), Brady Fire, USA
  5. Kim, D.E., "A Fundamental Study on the Application Methods of FDS for Fire Investigation in Residential Facilities", Master, pp.2011
  6. Kim, D.E., "Combustion characteristics of combustible materials and fire propagation for the analysis of fire behavior in domestic apartment house", Doctor, pp.2015