Optimal Placement of Needle Electromyography in Extensor Indicis: A Cadaveric Study
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objective To identify the center of extensor indicis (EI) muscle through cadaver dissection and compare the accuracy of different techniques for needle electromyography (EMG) electrode insertion.Methods Eighteen upper limbs of 10 adult cadavers were dissected. The center of trigonal EI muscle was defined as the point where the three medians of the triangle intersect. Three different needle electrode insertion techniques were introduced: M1, 2.5 cm above the lower border of ulnar styloid process (USP), lateral aspect of the ulna; M2, 2 finger breadths (FB) proximal to USP, lateral aspect of the ulna; and M3, distal fourth of the forearm, lateral aspect of the ulna. The distance from USP to the center (X) parallel to the line between radial head to USP, and from medial border of ulna to the center (Y) were measured. The distances between 3 different points (M1–M3) and the center were measured (marked as D1, D2, and D3, respectively). Results The median value of X was 48.3 mm and that of Y was 7.2 mm. The median values of D1, D2 and D3 were 23.3 mm, 13.3 mm and 9.0 mm, respectively.Conclusion The center of EI muscle is located approximately 4.8 cm proximal to USP level and 7.2 mm lateral to the medial border of the ulna. Among the three methods, the technique placing the needle electrode at distal fourth of the forearm and lateral to the radial side of the ulna bone (M3) is the most accurate and closest to the center of the EI muscle.
Abstract
Objective To identify the center of extensor indicis (EI) muscle through cadaver dissection and compare the accuracy of different techniques for needle electromyography (EMG) electrode insertion.Methods Eighteen upper limbs of 10 adult cadavers were dissected. The center of trigonal EI muscle was defined as the point where the three medians of the triangle intersect. Three different needle electrode insertion techniques were introduced: M1, 2.5 cm above the lower border of ulnar styloid process (USP), lateral aspect of the ulna; M2, 2 finger breadths (FB) proximal to USP, lateral aspect of the ulna; and M3, distal fourth of the forearm, lateral aspect of the ulna. The distance from USP to the center (X) parallel to the line between radial head to USP, and from medial border of ulna to the center (Y) were measured. The distances between 3 different points (M1–M3) and the center were measured (marked as D1, D2, and D3, respectively). Results The median value of X was 48.3 mm and that of Y was 7.2 mm. The median values of D1, D2 and D3 were 23.3 mm, 13.3 mm and 9.0 mm, respectively.Conclusion The center of EI muscle is located approximately 4.8 cm proximal to USP level and 7.2 mm lateral to the medial border of the ulna. Among the three methods, the technique placing the needle electrode at distal fourth of the forearm and lateral to the radial side of the ulna bone (M3) is the most accurate and closest to the center of the EI muscle.
참고문헌 (13)
- Leis AA, "Atlas of electromyography", pp.46~ (2000), Oxford University Press
- Komiyama M, "Variations of the extensor indicis muscle and tendon", J Hand Surg Br, 24, pp.575~578 (1999)[DOI]
- Pandey S, "A practical approach to management of focal hand dystonia", Ann Indian Acad Neurol, 18, pp.146~153 (2015)[DOI]
- Gray H, "Gray's anatomy: the anatomical basis of clinical practice. 40th ed", pp.851~ (2008), Churchill Livingstone
- Chu-Andrews J, "Electrodiagnosis: an anatomical and clinical approach", pp.144~ (1986), Lippincott Williams & Wilkins
- Perotto A, "Anatomical guide for the electromyographer: the limbs and trunk. 3rd ed", pp.45~46 (1994), Charles C. Thomas
- Lee HJ, "Surface anatomy for clinical needle electromyography", pp.178~179 (2000), Demos Medical Pub
- Karvelas K, "Resident accuracy of electromyography needle electrode placement using ultrasound verification", PM R, 8, pp.748~753 (2016)[DOI]
- Goodmurphy C, "The accuracy of needle placement in extremity muscles: a blinded study", J Clin Neurophysiol, 24, pp.366~378 (2007)
- In Yae Cheong, "Optimal Needle Placement for Extensor Hallucis Longus Muscle: A Cadaveric Study", Annals of Rehabilitation Medicine, 40(3), pp.457~462 (2016), 대한재활의학회
- Preston DC, "Electromyography and neuromuscular disorders: clinical-electrophysiologic correlations. 3rd ed", pp.148~ (2013), Elsevier
- Safwat MD, "Distribution of terminal nerve entry points to the flexor and extensor groups of forearm muscles: an anatomical study", Folia Morphol (Warsz), 66, pp.83~93 (2007)
- Molloy FM, "Accuracy of muscle localization without EMG: implications for treatment of limb dystonia", Neurology, 58, pp.805~807 (2002)[DOI]
