Ultrasonographic Analysis of Optimal Needle Placement for Extensor Indicis

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류재활의학

초록

Objective To determine the most optimal needle insertion point of extensor indicis (EI) using ultrasound. Methods A total 80 forearms of 40 healthy volunteers were recruited. We identified midpoint (MP) of EI using ultrasound and set MP as optimal needle insertion point. The location of MP was suggested using distances from landmarks. Distance from MP to medial border of ulna (MP-X) and to lower margin of ulnar head (MP-Y) were measured. Ratios of MP-X to Forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated. In cross-sectional view, depth of MP (Dmp), defined as middle value of superficial depth (Ds) and deep depth (Dd) was measured and suggested as proper depth of needle insertion. Results Mean MP-X was 1.37±0.14 cm and mean MP-Y was 5.50±0.46 cm. Mean X ratio was 8.10±0.53 and mean Y ratio was 22.15±0.47. Mean Dmp was 7.63±0.96 mm. Conclusion We suggested that novel optimal needle insertion point of the EI. It is about 7.6 mm in depth at about 22% of the forearm length proximal from the lower margin of the ulnar head and about 8.1% of the forearm circumference radial from medial border of ulna.

Abstract

Objective To determine the most optimal needle insertion point of extensor indicis (EI) using ultrasound. Methods A total 80 forearms of 40 healthy volunteers were recruited. We identified midpoint (MP) of EI using ultrasound and set MP as optimal needle insertion point. The location of MP was suggested using distances from landmarks. Distance from MP to medial border of ulna (MP-X) and to lower margin of ulnar head (MP-Y) were measured. Ratios of MP-X to Forearm circumference (X ratio) and MP-Y to forearm length (Y ratio) were calculated. In cross-sectional view, depth of MP (Dmp), defined as middle value of superficial depth (Ds) and deep depth (Dd) was measured and suggested as proper depth of needle insertion. Results Mean MP-X was 1.37±0.14 cm and mean MP-Y was 5.50±0.46 cm. Mean X ratio was 8.10±0.53 and mean Y ratio was 22.15±0.47. Mean Dmp was 7.63±0.96 mm. Conclusion We suggested that novel optimal needle insertion point of the EI. It is about 7.6 mm in depth at about 22% of the forearm length proximal from the lower margin of the ulnar head and about 8.1% of the forearm circumference radial from medial border of ulna.

참고문헌 (22)

  1. Netter FH, "Atlas of human anatomy", pp.2014, Saunders
  2. 임진영, "Optimal Placement of Needle Electromyography in Extensor Indicis: A Cadaveric Study", Annals of Rehabilitation Medicine, 42(3), pp.473~476 (2018), 대한재활의학회
  3. Komiyama M, "Variations of the extensor indicis muscle and tendon", J Hand Surg Br, 24, pp.575~578 (1999)
  4. Standring S, "Gray’s anatomy: the anatomical basis of clinical practice" (2015), Elsevier Health Sciences
  5. Neumann DA, "Kinesiology of the musculoskeletal system: foundations for rehabilitation" (2013), Elsevier Health Sciences
  6. Leis AA, "Atlas of electromyography" (2000), Oxford University Press
  7. Pandey S, "A practical approach to management of focal hand dystonia", Ann Indian Acad Neurol, 18, pp.146~153 (2015)
  8. Thomas AM, "Contralateral weakness following botulinum toxin for poststroke spasticity", Muscle Nerve, 46, pp.443~448 (2012)
  9. Dommerholt J, "Trigger point dry needling: an evidence and clinical-based approach" (2018), Elsevier Health Sciences
  10. Perotto AO, "Anatomical guide for the electromyographer: the limbs and trunk" (2011), Charles C. Thomas Publisher
  11. Lee HJ, "Manual of nerve conduction study and surface anatomy for needle electromyography" (2005), Lippincott Williams &Wilkins
  12. Chu-Andrews J, "Electrodiagnosis: an anatomical and clinical approach" (1986), Lippincott
  13. Goodmurphy C, "The accuracy of needle placement in extremity muscles : a blinded study", J Clin Neurophysiol, 24, pp.366~378 (2007)
  14. Karvelas K, "Resident accuracy of electromyography needle electrode placement using ultrasound verification", PM R, 8, pp.748~753 (2016)
  15. Tweedie A, "The library of Medicine" (1841), Whittaker
  16. Preston DC, "Electromyography and neuromuscular disorders: clinical-electrophysiologic correlations" (2012), Elsevier Health Sciences
  17. 여중호, "Optimal Radial Motor Nerve Conduction Study Using Ultrasound in Healthy Adults", Annals of Rehabilitation Medicine, 41(2), pp.290~298 (2017), 대한재활의학회
  18. Molloy FM, "Accuracy of muscle localization without EMG : implications for treatment of limb dystonia", Neurology, 58, pp.805~807 (2002)
  19. Safwat MD, "Distribution of terminal nerve entry points to the flexor and extensor groups of forearm muscles: an anatomical study", Folia Morphol(Warsz), 66, pp.83~93 (2007)
  20. 신승한, "Where Is the Ulnar Styloid Process? Identification of the Absolute Location of the Ulnar Styloid Process Based on CT and Verification of Neutral Forearm Rotation on Lateral Radiographs of the Wrist", Clinics in Orthopedic Surgery, 10(1), pp.80~88 (2018), 대한정형외과학회
  21. Yammine K, "The prevalence of the extensor indicis tendon and its variants : a systematic review and meta-analysis", Surg Radiol Anat, 37, pp.247~254 (2015)
  22. Georgiev GP, "Extensor indicis proprius muscle and its variants together with the extensor digitorum brevis manus muscle : a common classification : clinical significance in hand and reconstructive surgery", Surg Radiol Anat, 40, pp.271~280 (2018)

관련 논문AI추천

Optimal Placement of Needle Electromyography in Extensor Indicis: A Cadaveric Study김기훈, 김다솜, 김동휘, 박병규, 박홍범, 유임주, 이석준, 임성규, 임진영대한재활의학회 · Annals of Rehabilitation Medicine2018 · 제42권 제3호Ultrasonographic Evaluation of Needle Insertion Site for the Flexor Pollicis LongusHyun Seok Lee, Kihoon Kim, Sang Min Lee, Seung Min Lee대한재활의학회 · Annals of Rehabilitation Medicine2013 · 제37권 제2호Ultrasonographic Evaluation of the Needle Insertion Site for the Flexor Pollicis Longus Using the Flexor Carpi Radialis Tendon김동휘, 이항재, Kim Ki Hoon, Park Hong Bum, Ryou Chae Hyeon대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2023 · 제25권 제3호Morphologic Evaluation of the Flexor Carpi Radialis Muscle Using Ultrasonography for Accurate and Safe Needle Electromyography석현, 김상현, 안준영, 오백민, 이승열, 조연희대한근전도전기진단의학회 · 대한근전도 전기진단의학회지2021 · 제23권 제2호Safe Needle Insertion Locations for Motor Point Injection of the Triceps Brachii Muscle: A Pilot Cadaveric and Ultrasonography StudyDonggyun Sohn, Geun-Young Park, Hye Jung Park, Hyun Jung Koo, Sun Im, Yeonjae Han대한재활의학회 · Annals of Rehabilitation Medicine2019 · 제43권 제6호Anatomic Characteristics of Pronator Quadratus Muscle: A Cadaver StudyByung Kyu Park, Dong Hwee Kim, Hyung Soon Im, Im Joo Rhyu, Ki Hoon Kim, Min Young Kim, Phil Woo Choung대한재활의학회 · Annals of Rehabilitation Medicine2016 · 제40권 제3호

이 간행물의 다른 논문 (9건)