The main purpose of this study is to derive a regression equation that predicts the individual differences in activity energy expenditure (AEE) using accelerometer during different types of activity. Two subject groups were recruited separately in time: One is a homogeneous group of 94 healthy young adults with age ranged from 20 ~ 35 yrs. The other subject group has a broad spectrum of physical characteristics in terms of age and fat ratio. 226 adolescents and adults of age ranged from 12 ~ 57 yrs and fat ratio from 4.1 ~ 39.7% were in the second group. The wireless 3-axis accelerometers were developed and carefully fixed at the waist belt level. Simultaneously the total calorie expenditure was measured by gas analyzer. Each subject performed walking and running at speeds of 1.5, 3.0, 4.5, 6.0, 6.5, 7.5, and 8.5 km/hr. A generalized sensor-independent regression equation for AEE was derived. The regression equation was developed for walking and running. The regression coefficients were predicted as functions of physical factors - age, gender, height, and weight with multivariable regression analysis. The generalized calorie estimation equation predicts AEE with correlation coefficient of 0.96 and the average accuracy of the accumulated calorie was 89.6 ± 7.9%.

Abstract

The main purpose of this study is to derive a regression equation that predicts the individual differences in activity energy expenditure (AEE) using accelerometer during different types of activity. Two subject groups were recruited separately in time: One is a homogeneous group of 94 healthy young adults with age ranged from 20 ~ 35 yrs. The other subject group has a broad spectrum of physical characteristics in terms of age and fat ratio. 226 adolescents and adults of age ranged from 12 ~ 57 yrs and fat ratio from 4.1 ~ 39.7% were in the second group. The wireless 3-axis accelerometers were developed and carefully fixed at the waist belt level. Simultaneously the total calorie expenditure was measured by gas analyzer. Each subject performed walking and running at speeds of 1.5, 3.0, 4.5, 6.0, 6.5, 7.5, and 8.5 km/hr. A generalized sensor-independent regression equation for AEE was derived. The regression equation was developed for walking and running. The regression coefficients were predicted as functions of physical factors - age, gender, height, and weight with multivariable regression analysis. The generalized calorie estimation equation predicts AEE with correlation coefficient of 0.96 and the average accuracy of the accumulated calorie was 89.6 ± 7.9%.

참고문헌 (18)

  1. "energy, nutrition and human performance, Baltimore," (1996), Williams and Wilkins
  2. "New methods for calculating metabolic rate with special reference to protein metabolism", 109, pp.1~9 (1949)
  3. "A triaxial accelerometer for the assessment of daily physical activity in relation to energy expenditure", 93, pp.985~986 (1993)
  4. "Assessment of energy expenditure for physical activity using a triaxial accelerometer", 26, pp.1516~1523 (1994)
  5. "comparison between movement registration and doubly labeled water", 81, pp.1019~1026 (1996)
  6. "Validation of the tracmor triaxial accelerometer system for walking", 33, pp.1593~1597 (2001)
  7. "and calibration of the Tritrac accelerometer as a measure of physical activity", 31, pp.908~912 (1999)
  8. "Can accelerometry accurately predict the energy cost of uphill", downhill walking, 2001., pp.44, 48~62
  9. "Sirard"Calibration of the Computer Science and Applications, Inc. accelerometer"", 30, pp.777~781 (1998)
  10. "Validity of accelerometry for the assessment of moderate intensity physical activity in the field", 32, pp.442~449 (2000)
  11. "Estimation of energy expenditure using CSA accelerometers at hip and wrist sites", 32, pp.450~456 (2000)
  12. "Defining accelerometer thresholds for activity intensities in adolescent girls", 36, pp.1259~1266 (2004)
  13. "Body movement and physical activity energy expenditure in children and adolescents how to adjust for differences in body size and age", 79, pp.851~856 (2004)
  14. "Physical activity level measured by doubly labeled water and accelerometry in children", 89, pp.624~626 (2003)
  15. "Validity of the computer science and applications activity monitor in children", 30, pp.629~633 (1998)
  16. "Accuracy and reliability of the Caltrac accelerometer for estimating energy expenditure", 22, pp.858~862 (1990)
  17. "The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure", 31, pp.747~754 (1999)
  18. "Prediction of activity energy expenditure using accelerometers in children", 36, pp.1625~1631 (2004)