본문 바로가기
KERD
논문KCI 등재

Electro-Mechanical Safety Testing of Portable ECG Devices for Home Healthcare Usage

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Objectives: This paper suggests the experimental guidelines to evaluate the electro-mechanical safety of belt type equipment. The electro-mechanical safety was determined by using the International Electrotechnical Commission guidelines, which are widely used as important factors for assessing the electro-mechanical safety of belt type equipment. However, the local guidelines on wearable healthcare sensors are currently not well-established. Therefore, safety guidelines suited for the actual circumstances in Korea are required, and this paper attempts to try a new experimental safety test procedure of the wearable healthcare sensor. Methods: This belt type device measures the electrocardiogram (ECG) and heart rates by attaching to the chest. Examination lists were selected by analyzing the common standards ofelectro-mechanical safety (IEC 60601-1) and environment tests (IEC 60068-1, IEC 60068-2) of home-healthcare equipment. Results: The essential electrical safety, which was required for the RS300G3 as a medical device, was evaluated, and most of the examination lists were selected by considering the circumstances of the users. The device passed all the selected examinable lists that are applicable to the Korean environment. Conclusions: This study has limitations to estimate and to conduct electro-mechanical safety experiments because our study focused on the belt type of heart-rates equipment. We are not taking into account the overall electro-mechanical home-healthcare measurements. According to industrial and technological development, there are infinite possibilities for the advancement of home-healthcare equipment, so more examination lists for safety are being added in addition to what we have done.

Abstract

Objectives: This paper suggests the experimental guidelines to evaluate the electro-mechanical safety of belt type equipment. The electro-mechanical safety was determined by using the International Electrotechnical Commission guidelines, which are widely used as important factors for assessing the electro-mechanical safety of belt type equipment. However, the local guidelines on wearable healthcare sensors are currently not well-established. Therefore, safety guidelines suited for the actual circumstances in Korea are required, and this paper attempts to try a new experimental safety test procedure of the wearable healthcare sensor. Methods: This belt type device measures the electrocardiogram (ECG) and heart rates by attaching to the chest. Examination lists were selected by analyzing the common standards ofelectro-mechanical safety (IEC 60601-1) and environment tests (IEC 60068-1, IEC 60068-2) of home-healthcare equipment. Results: The essential electrical safety, which was required for the RS300G3 as a medical device, was evaluated, and most of the examination lists were selected by considering the circumstances of the users. The device passed all the selected examinable lists that are applicable to the Korean environment. Conclusions: This study has limitations to estimate and to conduct electro-mechanical safety experiments because our study focused on the belt type of heart-rates equipment. We are not taking into account the overall electro-mechanical home-healthcare measurements. According to industrial and technological development, there are infinite possibilities for the advancement of home-healthcare equipment, so more examination lists for safety are being added in addition to what we have done.

참고문헌 (4)

  1. Song JE, "Security issues and its technology trends in U-healthcare", Electron Telecommun Trends, 22, pp.119~129 (2007)
  2. 이영동, "유비쿼터스 헬스케어를 위한 센서 네트워크 기반의 심전도 및체온 측정 시스템: 1. 센서 네트워크 플랫폼 구축", 센서학회지, 15(5), pp.362~370 (2006), 한국센서학회
  3. Ahn KH, "Healthcare system for Blood Glucose Monitoring", Proceedings of 2004 spring conference of the Korean Society for Internet Information (2004), Korean Society for Internet Information
  4. 김형돈, "최대하 운동부하 검사시 심박수 회복 반응과 심혈관계질환(CVD) 위험 요소와의 관계", 한국체육학회지, 44(4), pp.299~307 (2005), 한국체육학회