가상실현 기반 구급차에서 루카스와 수기에 의한 가슴압박과 인공호흡 비교 -마네킨 연구-
Comparison of chest compression and ventilation volume using LUCAS and manual in virtual reality-based ambulance simulation -A manikin study-
1
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the quality of chest compressions and ventilation when using an mechanical device(LUCAS) and 2-men manual cardiopulmonary resuscitation(CPR) performed on a minikin, as well as to propose a more effective CPR method during transit. Methods: Data were collected by LUCAS and manual virtual reality based ambulance simulation. Analysis was performed using SPSS software 12.0. The average and standard deviation of chest compression depth and ventilation were analyzed using descriptive statistics and t-test. Results: In the virtual reality based LUCAS and manual CPR results, LUCAS showed better chest compression and lower incomplete chest release than manual CPR. During CPR with a chest compression-ventilation ratio of 30:2 in virtual reality ventilation with bag-valve mask was able to deliver an adequate volume of breathing. Conclusion: It is suggested that rescuers on ambulance may consider using LUCAS as an alternative to high-quality chest compression during transit.
Abstract
Purpose: The purpose of this study was to evaluate the quality of chest compressions and ventilation when using an mechanical device(LUCAS) and 2-men manual cardiopulmonary resuscitation(CPR) performed on a minikin, as well as to propose a more effective CPR method during transit. Methods: Data were collected by LUCAS and manual virtual reality based ambulance simulation. Analysis was performed using SPSS software 12.0. The average and standard deviation of chest compression depth and ventilation were analyzed using descriptive statistics and t-test. Results: In the virtual reality based LUCAS and manual CPR results, LUCAS showed better chest compression and lower incomplete chest release than manual CPR. During CPR with a chest compression-ventilation ratio of 30:2 in virtual reality ventilation with bag-valve mask was able to deliver an adequate volume of breathing. Conclusion: It is suggested that rescuers on ambulance may consider using LUCAS as an alternative to high-quality chest compression during transit.
참고문헌 (24)
- Ian G. Stiell, "What Is the Optimal Chest Compression Depth During Out-of-Hospital Cardiac Arrest Resuscitation of Adult Patients?", Circulation, 130(22), pp.1962~1970 (2014), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Jim Christenson, "Chest Compression Fraction Determines Survival in Patients With Out-of-Hospital Ventricular Fibrillation", Circulation, 120(13), pp.1241~1247 (2009), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Stephen H. Thomas, "The ability to perform closed chest compressions in helicopters", The American Journal of Emergency Medicine, 12(3), pp.296~298 (1994), Elsevier BV[DOI]
- Jo Kramer-Johansen, "Quality of out-of-hospital cardiopulmonary resuscitation with real time automated feedback: A prospective interventional study", Resuscitation, 71(3), pp.283~292 (2006), Elsevier BV[DOI]
- 신소연, "구급차 내에서의 심폐소생술 방법에 관한 연구", 한국화재소방학회 논문지, 28(4), pp.104~111 (2014), 한국화재소방학회[DOI]
- 장문순, "시간 경과에 따른 1인 심폐소생술의 질과 피로도의 변화", 한국응급구조학회지, 17(1), pp.9~19 (2013), 사단법인 한국응급구조학회
- Lars Wik, "Manual vs. integrated automatic load-distributing band CPR with equal survival after out of hospital cardiac arrest. The randomized CIRC trial", Resuscitation, 85(6), pp.741~748 (2014), Elsevier BV[DOI]
- Sten Rubertsson, "Mechanical Chest Compressions and Simultaneous Defibrillation vs Conventional Cardiopulmonary Resuscitation in Out-of-Hospital Cardiac Arrest", JAMA, 311(1), pp.53~ (2014), American Medical Association (AMA)[DOI]
- Gavin D Perkins, "Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial", The Lancet, 385(9972), pp.947~955 (2015), Elsevier BV[DOI]
- Matthew J. Mitten, "Eligibility and Disqualification Recommendations for Competitive Athletes With Cardiovascular Abnormalities: Task Force 15: Legal Aspects of Medical Eligibility and Disqualification Recommendations", Circulation, 132(22) (2015), Ovid Technologies (Wolters Kluwer Health)[DOI]
- 지아람, "병원 밖 심정지에서 현장의 수직 위치와 기계심폐소생장치가 소생 결과에 미치는 영향에 대한 관찰연구", 대한응급의학회지, 27(6), pp.530~539 (2016), 대한응급의학회
- "2015 AHA Guidelines for CPR and ECC", AHA, ~
- Kim GY., "The effect of EMT belt on chest compressions in moving ambulance", master, pp.2014
- 홍성기, "구급차내 심폐소생술시 흉부압박의 정확도에 영향을 미치는 요인", 대한응급의학회지, 20(4), pp.343~354 (2009), 대한응급의학회
- Sandra Braunfels, "A randomized, controlled trial of the efficacy of closed chest compressions in ambulances", Prehospital Emergency Care, 1(3), pp.128~131 (2009), Informa UK Limited[DOI]
- Ochoa FJ, "The effect of rescuer fatigue on the quality of chest compressions", Resuscitation, 37(3), pp.149~152 (1998)
- 신소연, "옥시레이터 EM-100을 활용한 환기량과 기도내압 비교", 한국화재소방학회 논문지, 29(5), pp.104~109 (2015), 한국화재소방학회[DOI]
- 조승묵, "Bag-Valve-Mask의 사용방법에 따른 일회호흡량과 평균기도압의 변화 연구", 한국응급구조학회지, 16(2), pp.67~74 (2012), 사단법인 한국응급구조학회
- Cho YC, "How can a single rescuer adequately deliver tidal volume with a manual resuscitator? An improved device for device for delivering regular tidal volume", Emergency Medicine Journal, 28(1), pp.40~43 (2011)
- Tom P. Aufderheide, "Hyperventilation-Induced Hypotension During Cardiopulmonary Resuscitation", Circulation, 109(16), pp.1960~1965 (2004), Ovid Technologies (Wolters Kluwer Health)[DOI]
- 한규근, "성인 병원전 심정지 환자에게 심폐소생술시 AutoPulseTM 장치를 이용한 흉부 압박과 수기 흉부 압박이 결과에 미치는 영향", 대한응급의학회지, 20(3), pp.256~263 (2009), 대한응급의학회
- 조영신, "시뮬레이션된 병원전 심정지에서 구급대원에 의한 가슴압박과 기계압박의 비교", 대한응급의학회지, 23(4), pp.486~492 (2012), 대한응급의학회
- Tae Han Kim, "Quality between mechanical compression on reducible stretcher versus manual compression on standard stretcher in small elevator", The American Journal of Emergency Medicine, 34(8), pp.1604~1609 (2016), Elsevier BV[DOI]