본문 바로가기
KERD
논문KCI 등재

Capability of Radial- and Convex-Arrayed Echoendoscopes for Visualization of the Pancreatobiliary Junction

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류내과학

초록

Background/Aims: Although both radial- and convex-arrayed endoscopic ultrasonography (EUS) scopes are widely used forobservational EUS examinations, there have been few comparative studies on their power of visualization. The aim of this study was toevaluate the capability of these EUS scopes for observation of the pancreatobiliary junction. Methods: The rate of successful visualization of the pancreatobiliary junction was retrospectively compared between a radial-arrayedand a convex-arrayed echoendoscope, from a prospectively maintained database. Study periods were defined as January 2010 toDecember 2012 for the radial group, and February 2015 to October 2016 for the convex group because the respective scope wasmainly used during those periods. Results: During the study period, 1,660 cases with radial EUS and 1,984 cases with convex EUS were recruited. The success rates ofobservation of the pancreatobiliary junction were 80.0% and 89.5%, respectively (p<0.0001). Conclusions: The capability of visualization of the pancreatobiliary junction in observational EUS was found to be better with aconvex-arrayed than with a radial-arrayed echoendoscope

Abstract

Background/Aims: Although both radial- and convex-arrayed endoscopic ultrasonography (EUS) scopes are widely used forobservational EUS examinations, there have been few comparative studies on their power of visualization. The aim of this study was toevaluate the capability of these EUS scopes for observation of the pancreatobiliary junction. Methods: The rate of successful visualization of the pancreatobiliary junction was retrospectively compared between a radial-arrayedand a convex-arrayed echoendoscope, from a prospectively maintained database. Study periods were defined as January 2010 toDecember 2012 for the radial group, and February 2015 to October 2016 for the convex group because the respective scope wasmainly used during those periods. Results: During the study period, 1,660 cases with radial EUS and 1,984 cases with convex EUS were recruited. The success rates ofobservation of the pancreatobiliary junction were 80.0% and 89.5%, respectively (p<0.0001). Conclusions: The capability of visualization of the pancreatobiliary junction in observational EUS was found to be better with aconvex-arrayed than with a radial-arrayed echoendoscope

참고문헌 (11)

  1. Sugiyama M, "Endoscopic ultrasonography for diagnosing choledocholithiasis: a prospective comparative study with ultrasonography and computed tomography", Gastrointest Endosc, 45, pp.143~146 (1997)[DOI]
  2. Kondo S, "Detection of common bile duct stones: comparison between endoscopic ultrasonography, magnetic resonance cholangiography, and helical-computed-tomographic cholangiography", Eur J Radiol, 54, pp.271~275 (2005)[DOI]
  3. Mirbagheri SA, "Prospective evaluation of endoscopic ultrasonography in the diagnosis of biliary microlithiasis in patients with normal transabdominal ultrasonography", J Gastrointest Surg, 9, pp.961~964 (2005)[DOI]
  4. Ney MV, "Echo-endoscopy versus endoscopic retrograde cholangiography for the diagnosis of choledocholithiasis: the influence of the size of the stone and diameter of the common bile duct", Arq Gastroenterol, 42, pp.239~243 (2005)[DOI]
  5. Mitake M, "Value of endoscopic ultrasonography in the detection of anomalous connections of the pancreatobiliary duct", Endoscopy, 23, pp.117~120 (1991)[DOI]
  6. Sugiyama M, "Endoscopic ultrasonography for diagnosing anomalous pancreaticobiliary junction", Gastrointest Endosc, 45, pp.261~267 (1997)[DOI]
  7. Tanaka M, "International consensus guidelines 2012 for the management of IPMN and MCN of the pancreas", Pancreatology, 12, pp.183~197 (2012)[DOI]
  8. Katanuma A, "The difference in the capability of delineation between convex and radial arrayed echoendoscope for pancreas and biliary tract; case reports from the standpoint of both convex and radial arrayed echoendoscope", Dig Endosc, 23(Suppl 1), pp.2~8 (2011)[DOI]
  9. Hara K, "A convex EUS is useful to diagnose vascular invasion of cancer, especially hepatic hilus cancer", Dig Endosc, 23(Suppl 1), pp.26~28 (2011)[DOI]
  10. Kaneko M, "Prospective, randomized, comparative study of delineation capability of radial scanning and curved linear array endoscopic ultrasound for the pancreaticobiliary region", Endosc Int Open, 2, pp.E160~E170 (2014)[DOI]
  11. Ito K, "Preoperative evaluation of ampullary neoplasm with EUS and transpapillary intraductal US: a prospective and histopathologically controlled study", Gastrointest Endosc, 66, pp.740~747 (2007)[DOI]

관련 논문AI추천

Convex versus Radial Echoendoscopes - Comparison of Capability for Evaluating the Pancreatobiliary Junction김동욱, Sung Yong Han대한소화기내시경학회 · Clinical Endoscopy2018 · 제51권 제3호Evaluation of the Feasibility and Efficacy of Forward-Viewing Endoscopic Ultrasound김명환, 박도환, 서동완, 이상수, 이서현, 이성구, 최준호거트앤리버 소화기연관학회협의회 · Gut and Liver2015 · 제9권 제5호Technical tips for endoscopic ultrasound-guided pancreatic duct access and drainageYousuke Nakai소화기인터벤션의학회 · International Journal of Gastrointestinal Intervention2020 · 제9권 제4호Feasibility of Newly Developed Endoscopic Ultrasound with Zone Sonography Technology for Diagnosis of Pancreatic DiseasesAkihiro Itoh, Daijiro Hayashi, Eizaburo Ohno, Hajime Sumi, Hidemi Goto, Hiroki Kawashima, Hiroyuki Sugimoto, Kohei Funasaka, Masanao Nakamura, Masatoshi Ishigami, Naoki Ohmiya, Ryoji Miyahara, Takeshi Hiramatsu, Yoshiaki Katano, Yoshiki Hirooka, Yosuke Nakamura, Yuya Itoh거트앤리버 소화기연관학회협의회 · Gut and Liver2013 · 제7권 제4호Comparison of intraductal ultrasonographydirected and cholangiography-directed endoscopic retrograde biliary drainage in patients with a biliary obstructionChang-Hwan Park, Du-Hyeon Lee, Hyun Soo Kim, Jin Jeon, Jong-Sun Rew, Soo-Jung Rew, Sung Kyu Choi대한내과학회 · The Korean Journal of Internal Medicine2016 · 제31권 제5호Diagnostic Ability of Convex-Arrayed Endoscopic Ultrasonography for Major Vascular Invasion in Pancreatic CancerDaisuke Uchida, Hironari Kato, Hiroyuki Okada, Kazuyuki Matsumoto, Noriyuki Tanaka, Saimon Takada, Shigeru Horiguchi, Shinichiro Muro, Sho Mizukawa, Takeshi Tomoda, Yosuke Saragai, Yuki Fujii대한소화기내시경학회 · Clinical Endoscopy2019 · 제52권 제5호

이 간행물의 다른 논문 (15건)